<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2022.097</article-id>
      <article-id pub-id-type="publisher-id">2022.097</article-id>
      <title-group><article-title>The deployment and demonstration of a super performance indirect evaporative cooler in real-life data centres</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Zeng</surname><given-names>Cheng</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>C.Zeng@hull.ac.uk</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Zhu</surname><given-names>Zishang</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Li</surname><given-names>Yunhai</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Wang</surname><given-names>Zhichu</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Ma</surname><given-names>Xiaoli</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Zhao</surname><given-names>Xudong</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">School of Engineering, University of Hull, Hull, HU6 7RX, UK</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>16</day><month>02</month><year>2023</year></pub-date>
      <volume>19</volume>
      <issue>3</issue>
      <isbn publication-format="electronic">978-0-85358-351-6</isbn>
      <fpage>55</fpage>
      <lpage>63</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2022.097"/>
      <history>
        <date date-type="received"><string-date>16 February 2023</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2022 Copyright WSSET</copyright-statement>
        <copyright-year>2023</copyright-year>
      </permissions>
      <abstract><p>Energy-efficient cooling and ventilation is critical to reduce carbon emissions and cut energy bills, especially for traditional data centres, which use around 20% of global data centre energy demand. This paper presents the latest deployment demonstration projects using the super performance dew point cooling technology in real life data centre businesses. With over 15-years’ continuous endeavour, the researchers at the University of Hull have developed a specialised indirect evaporative cooler which has achieved a COP of 52.5 in the laboratory setting. With the super performance cooler tested in laboratory in 2021, the authors have applied and demonstrated the technology in two real-life data centres to meet the peak cooling demand of up to 100 kW. This was the first project which applied the technology to real-world business in a relatively large scale, which has generated surprising results that were highly valuable and interesting to share with peers working in the field of low carbon technologies, especially the sustainable heating and cooling area. This paper covers the latest findings from the project, including the innovations, the project, the demonstration system, energy performance, real life data and results, as well as the project learnings.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>indirect evaporative cooling</kwd>
        <kwd>real life demonstration</kwd>
        <kwd>energy performance</kwd>
        <kwd>data centre cooling</kwd>
      </kwd-group>
      <conference>
        <conf-date>16 to 18 August 2022</conf-date>
        <conf-name>19th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2022</conf-acronym>
        <conf-num>19</conf-num>
        <conf-loc>Istanbul, Turkiye</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
