<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2023.019</article-id>
      <article-id pub-id-type="publisher-id">2023.019</article-id>
      <title-group><article-title>The intermittency and flexibility of heating systems with different terminal types in buildings</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Xu</surname><given-names>Baoping</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <xref ref-type="aff" rid="aff2"/>
        <email>Baoping.Xu@nottingham.ac.uk</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Li</surname><given-names>Qiangang</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Dou</surname><given-names>Yanzhe</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Yan</surname><given-names>Yuying</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>Yuying.Yan@nottingham.ac.uk</email>
      </contrib>
      <aff id="aff1">University of Nottingham, Nottingham NG7 2RD, United Kingdom</aff>
      <aff id="aff2">North China Electric Power University, Beijing 102206, China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>15</day><month>12</month><year>2023</year></pub-date>
      <volume>20</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-0-85358-357-8</isbn>
      <fpage>169</fpage>
      <lpage>178</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2023.019"/>
      <history>
        <date date-type="received"><string-date>15 December 2023</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2023 Copyright WSSET</copyright-statement>
        <copyright-year>2023</copyright-year>
      </permissions>
      <abstract><p>The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking central heating. As a major component of heating systems, heating terminals have great effect on both intermittency and flexibility of the system. In this study, an integrated dynamic model was developed by considering the interaction of thermal processes among building envelopes, terminals, and heat pumps. The radiant heat transfer ratio of the heating terminal, which was introduced in the dynamic thermal balance equations, was a key parameter to describe the characteristic of heat transfer between the terminal and the building. Field tests demonstrated that the simulated results were closer to the tested values when considering the proposed ratio. An intermittent heating control strategy as well as demand response operation were applied to heat pump heating systems respectively. The effect of different terminals on room temperature response speed, energy saving rate, load shifting rate and load shifting efficiency was analysed. The results indicated that heat pumps under intermittent heating were more efficient in buildings with convective heating terminals. Specifically, fan-coil heating systems could use 16.48% less energy, while radiant floor heating systems consumed more energy under intermittent heating. For buildings with convective terminals (such as fan coils), the warm-up time was 0.09 h to 0.33 h, and for those with convective-radiative terminals (such as radiators), the warm-up time was 0.23 h to 4 h under daily intermittent heating, while there was nearly no need to preheat in buildings with radiative terminals (such as radiant floors). On the other hand, the buildings with radiative heating terminals had better flexibility potential. By adopting the model predictive control strategy, the load shifting ratio of radiator heating systems was about 2.9 times that of fan coil heating systems. Finally, an idea of a novel radiation-adjustable heating terminal was proposed in order to achieve both intermittency and flexibility.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Heating terminal</kwd>
        <kwd>Radiant heat transfer ratio</kwd>
        <kwd>Intermittent heating</kwd>
        <kwd>Demand response</kwd>
        <kwd>Load shifting ratio</kwd>
      </kwd-group>
      <conference>
        <conf-date>15 to 17 August 2023</conf-date>
        <conf-name>20th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2023</conf-acronym>
        <conf-num>20</conf-num>
        <conf-loc>Nottingham, UK</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
