<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2023.110</article-id>
      <article-id pub-id-type="publisher-id">2023.110</article-id>
      <title-group><article-title>Power quality impacts of grid-tied PV inverters on low voltage distribution networks: A smart OpenDSS model to find power quality threshold limits</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Attanayake</surname><given-names>Chinthaka</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>chinthaka.attanayake@ceb.lk</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Gunathilake</surname><given-names>Nilupulee</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>n.gunathilake@napier.ac.uk</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Ekanayake</surname><given-names>Janaka</given-names></name>
        <xref ref-type="aff" rid="aff3"/>
        <email>ekanayakej@eng.pdn.ac.lk</email>
      </contrib>
      <aff id="aff1">Generation Protection, Ceylon Electricity Board, Sri Lanka</aff>
      <aff id="aff2">School of Computing, Engineering &amp; the Built Environment, Edinburgh Napier University, UK</aff>
      <aff id="aff3">Faculty of Engineering, University of Peradeniya</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>15</day><month>12</month><year>2023</year></pub-date>
      <volume>20</volume>
      <issue>3</issue>
      <isbn publication-format="electronic">978-0-85358-357-8</isbn>
      <fpage>156</fpage>
      <lpage>166</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2023.110"/>
      <history>
        <date date-type="received"><string-date>15 December 2023</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2023 Copyright WSSET</copyright-statement>
        <copyright-year>2023</copyright-year>
      </permissions>
      <abstract><p>As a renewable initiative, risen attention can be seen in solar photovoltaic (PV) installations in the world. Since tropical countries and even many other countries during summer experience higher irradiance levels, there is great potential for PV generation in solar panels. However, power quality can be impacted when the number of PV modules is increased in a network due to the emergence of harmonics, unbalanced voltages, voltage flicker, neutral voltage variations, etc. Therefore, it is essential to empirically analyse power quality parameters, i.e., total harmonic distortion (THD), voltage unbalance, etc., and find threshold margins of PV capacities in a network. Based on a case study conducted in Negombo, Sri Lanka, this work determines power quality impacts with reference to the number of PV interconnections in a distributed network. For the task, a low-voltage distribution network was chosen which was fed by a 250kVA, 11/0.4kV transformer with domestic loads and grid-tied PV inverters. A simulation model was developed in Open Distribution System Simulator (OpenDSS) with time-varying load patterns and PV generation. Consequently, a smart efficient method was introduced to model domestic loads with unique time-varying demand patterns. A determination criterion was established to derive snapshot load flow instants using time-varying load flow results to analyse voltage profiles along distribution feeders. Then, the model was enhanced to quantify the power quality parameters such as individual harmonic content, THD of voltage as well as current and neutral voltage variation. The results reveal that node voltage has improved with PV interception without violating the upper limit. The THD of voltage and current have slightly increased with the addition of PV inverters.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Solar PV</kwd>
        <kwd>renewable energy</kwd>
        <kwd>low voltage distribution</kwd>
        <kwd>power quality</kwd>
        <kwd>OpenDSS</kwd>
      </kwd-group>
      <conference>
        <conf-date>15 to 17 August 2023</conf-date>
        <conf-name>20th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2023</conf-acronym>
        <conf-num>20</conf-num>
        <conf-loc>Nottingham, UK</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>