<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2024.048</article-id>
      <article-id pub-id-type="publisher-id">2024.048</article-id>
      <title-group><article-title>Optimization of solar-air dual-source heat pump system with phase change heat storage in a duck shed in China</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Yu</surname><given-names>Tao</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>yutao1978@sdjzu.edu.cn</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Che</surname><given-names>Yuqing</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>773793651@qq.com</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Song</surname><given-names>Enqiang</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>799609315@qq.com</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Chen</surname><given-names>Yi</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>382430862@qq.com</email>
      </contrib>
      <aff id="aff1">Shandong Jianzhu University, Fengming road 10000, Jinan, China</aff>
      <aff id="aff2">Shandong Wanbang Construction Technology Co., Ltd, Jinan, China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>12</day><month>12</month><year>2024</year></pub-date>
      <volume>21</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-0-85358-356-1</isbn>
      <fpage>469</fpage>
      <lpage>472</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2024.048"/>
      <history>
        <date date-type="received"><string-date>12 December 2024</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2024 Copyright University of Nottingham &amp; WSSET</copyright-statement>
        <copyright-year>2024</copyright-year>
      </permissions>
      <abstract><p>The study focuses on a duck shed located in North China with the heat load index of 218 W/m2. A solar-air dual-source heat pump system with phase change heat storage (SAHP-PC) was designed, and optimized in TRNSYS simulation. The results show that the optimal conditions are: setting solar collectors to half of the heating area, matching per unit area collector with 20L water tank, and controlling the splitting ratio of water-source heat pump to air-source heat pump at 7:3. Then the COP of water-source heat pump reaches 5.05, the solar fraction is 62%, corresponding to an energy-saving rate of 23%.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Phase Change Heat Storage</kwd>
        <kwd>Solar-Air Source Heat Pump</kwd>
        <kwd>Splitting Ratio</kwd>
        <kwd>Duck Shed</kwd>
      </kwd-group>
      <conference>
        <conf-date>12 to 14 August 2024</conf-date>
        <conf-name>21st International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2024</conf-acronym>
        <conf-num>21</conf-num>
        <conf-loc>Shanghai, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
