<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2026.024</article-id>
      <article-id pub-id-type="publisher-id">2026.024</article-id>
      <title-group><article-title>Characterisation of Bedroom Thermal Microclimates Influencing Sleep Quality in Diverse Residential Settings in Kerala: Integrating Indoor Environmental Monitoring, PMV and Sleep Assessment</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Ashok</surname><given-names>Anagha</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Conceptualization</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Methodology</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Investigation</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Formal analysis</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Data curation</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Writing (original draft)</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Visualization</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Validation</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Software</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Resources</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Writing (review and editing)</role>
        <email>anaghasubhadram@gmail.com</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>R</surname><given-names>Deepa Rani</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Conceptualization</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Methodology</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Writing (review and editing)</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Supervision</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Resources</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Software</role>
        <role vocab="credit" vocab-identifier="https://credit.niso.org/">Project administration</role>
        <email>deeparani.r@gmail.com</email>
      </contrib>
      <aff id="aff1"><institution-wrap><institution>Department of Architecture and Planning, College of Engineering Trivandrum, Thiruvananthapuram, Kerala, India</institution><institution-id institution-id-type="ror">https://ror.org/01q6dzp07</institution-id></institution-wrap></aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>23</day><month>11</month><year>2026</year></pub-date>
      <volume>22</volume>
      <isbn publication-format="electronic">978-1-995850-00-9</isbn>
      <fpage>285</fpage>
      <lpage>292</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2026.024"/>
      <history>
        <date date-type="received"><day>31</day><month>5</month><year>2026</year></date>
        <date date-type="rev-recd"><day>30</day><month>6</month><year>2026</year></date>
        <date date-type="accepted"><day>12</day><month>7</month><year>2026</year></date>
      </history>
      <permissions>
        <copyright-statement>© 2026 The Author(s). Published by Caravel Press.</copyright-statement>
        <copyright-year>2026</copyright-year>
        <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/">
          <license-p>This is an open access article under the CC BY 4.0 licence.</license-p>
        </license>
      </permissions>
      <abstract><p>Sleep quality in Kerala’s warm-humid climate is strongly influenced by night-time temperatures, persistent humidity, and restricted natural ventilation—factors that directly affect human thermoregulation and the stability of circadian rhythms. As traditional, well-ventilated homes are increasingly replaced by compact urban dwellings with restricted airflow, indoor environments are gradually diverging from climate-responsive design principles that historically supported nocturnal comfort. Therefore, this study investigates how bedroom thermal microclimates characterised by localised variations in temperature, humidity, airflow, and indoor air quality shape sleep quality across diverse residential settings in Kerala. A mixed-method approach is employed, integrating continuous environmental monitoring (temperature, humidity, and CO₂ levels), thermal comfort assessment using Predicted Mean Vote (PMV) indices, smart watch-based sleep tracking, and subjective evaluations through the Pittsburgh Sleep Quality Index (PSQI) in selected bedrooms in residential buildings. The results reveal a clear inverse relationship between thermal discomfort and deep sleep duration. As PMV values increase, indicating warmer and more uncomfortable conditions, deep sleep duration consistently decreases, a trend that remains evident even after accounting for age-related variations in sleep duration. Nights with PMV values exceeding 1.6 are associated with significantly reduced deep sleep (approximately 0.42 hours), whereas more moderate conditions with PMV values in the range of 1.2–1.3 correspond to higher deep sleep durations (approximately 0.55–0.60 hours). These findings establish PMV as a meaningful indicator linking indoor thermal conditions with sleep quality outcomes in warm-humid residential environments, demonstrating that elevated temperature and humidity significantly compromise sleep efficiency and continuity.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Warm-humid climate</kwd>
        <kwd>Sleep quality</kwd>
        <kwd>Thermal comfort</kwd>
        <kwd>Predicted mean vote (PMV)</kwd>
        <kwd>Indoor environmental quality (IEQ)</kwd>
        <kwd>Bedroom microclimate</kwd>
        <kwd>Pittsburgh Sleep Quality Index</kwd>
      </kwd-group>
      <funding-group>
        <funding-statement>This research received no specific funding.</funding-statement>
      </funding-group>
      <conference>
        <conf-date>13 to 15 August 2026</conf-date>
        <conf-name>22nd International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2026</conf-acronym>
        <conf-num>22</conf-num>
        <conf-loc>Kuala Lumpur, Malaysia</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
    <sec id="sec1">
      <title>Introduction</title>
      <p>Sleep is a fundamental physiological process essential for maintaining physical health, cognitive function, and emotional well-being. Poor sleep quality has been associated with adverse health outcomes, including cardiovascular disease, metabolic disorders, and impaired cognitive performance (<xref ref-type="bibr" rid="ref-fbc7dbe7-8664-48ce-acea-d15c1b7ccc27">Buysse <italic>et al.</italic> 1989</xref>). Since individuals spend approximately one-third of their lives indoors during sleep, the bedroom environment plays a critical role in influencing sleep quality.</p>
      <p>Among indoor environmental factors, the thermal environment is particularly important because sleep is closely linked to human thermoregulation. During sleep onset, the body dissipates heat through peripheral vasodilation and a reduction in core body temperature. Elevated indoor temperatures and excessive humidity interfere with this process, leading to delayed sleep onset, reduced deep sleep, and increased nocturnal awakenings (<xref ref-type="bibr" rid="ref-aeef8003-7fec-4b46-9f55-04a1ffcfcfa7">Okamoto-Mizuno and Mizuno 2012</xref>). In warm-humid climates, where night-time temperatures remain high and humidity restricts evaporative cooling, maintaining a comfortable sleeping environment becomes especially challenging.</p>
      <p>Kerala's tropical climate is characterised by persistently high temperatures and relative humidity throughout much of the year. Traditionally, residential buildings incorporated climate-responsive features such as large openings, courtyards, and high ceilings to enhance natural ventilation. However, rapid urbanisation has led to compact residential developments with reduced airflow and increased heat retention, potentially affecting indoor thermal comfort and sleep quality.</p>
      <p>Recent studies have demonstrated that bedroom ventilation and indoor environmental quality significantly influence sleep outcomes. <xref ref-type="bibr" rid="ref-9def411f-4f3e-42b9-bbc3-22648f2776fd">Fan <italic>et al.</italic> (2023)</xref> found that improved bedroom ventilation enhanced objectively measured sleep quality, while <xref ref-type="bibr" rid="ref-4c6ae84c-0366-45f8-bd35-3a80f134f378">Akimoto <italic>et al.</italic> (2025)</xref> reported that inadequate ventilation and elevated indoor CO₂ concentrations were consistently associated with poorer sleep performance. These findings highlight the importance of assessing multiple indoor environmental parameters rather than temperature alone.</p>
      <p>Despite growing research on thermal comfort and sleep, field-based studies investigating bedroom thermal microclimates in naturally ventilated residential buildings within tropical climates remain limited, particularly in the Indian context. This study addresses this gap by characterising bedroom thermal microclimates across diverse residential settings in Kerala and examining their influence on sleep quality. A mixed-method approach integrating continuous monitoring of temperature, relative humidity, carbon dioxide concentration, thermal comfort assessment using Predicted Mean Vote (PMV), smart watch-based sleep tracking, and the Pittsburgh Sleep Quality Index (PSQI) was employed. The findings aim to provide evidence for climate-responsive residential design strategies that promote healthier indoor sleeping environments.</p>
    </sec>
    <sec id="sec2">
      <title>Materials and methods</title>
      <p>This study adopted a mixed-method approach to characterise bedroom thermal microclimates and evaluate their influence on sleep quality in diverse residential settings across Kerala. Objective environmental measurements were integrated with subjective and objective sleep assessments to establish relationships between indoor thermal conditions and sleep outcomes. The methodology comprised continuous monitoring of bedroom environmental parameters, thermal comfort assessment using the Predicted Mean Vote (PMV) model, smart watch-based sleep monitoring, and subjective evaluation using the Pittsburgh Sleep Quality Index (PSQI).</p>
      <sec id="sec3">
        <title>Study Area and Sample Selection</title>
        <p>Ten naturally ventilated bedrooms located in different districts of Kerala were selected to represent diverse residential settings and ventilation conditions. Participants belonged to two age groups (24–35 years and 36–50 years), were in good general health, and did not use sleep medication. Both single-occupancy and shared bedrooms were included to capture variations in residential sleeping environments.</p>
        <p>Bedroom ventilation was classified into four categories based on the configuration of windows and doors during the sleeping period: V1 (window and door open—cross ventilation), V2 (window open and door closed), V3 (partially open window), and V4 (window closed).</p>
        <table-wrap id="tbl1">
          <label>Table 1</label>
          <caption><p>Ventilation types adopted for the surveyed bedrooms.</p></caption>
          <table>
            <thead>
              <tr>
                <th>Code</th>
                <th>Description</th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td>V1</td>
                <td>Window open + door open</td>
              </tr>
              <tr>
                <td>V2</td>
                <td>Window open + door closed</td>
              </tr>
              <tr>
                <td>V3</td>
                <td>Window partially open</td>
              </tr>
              <tr>
                <td>V4</td>
                <td>Window closed</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
        <p>Other characteristics of the surveyed rooms were observed and tabulated as follows:</p>
        <table-wrap id="tbl2">
          <label>Table 2</label>
          <caption><p>Characteristics of the surveyed bedrooms.</p></caption>
          <table>
            <thead>
              <tr>
                <th>Cases</th>
                <th>Location</th>
                <th>Floor level</th>
                <th>Bed orientation</th>
                <th>Ventilation type</th>
                <th>Mechanical ventilation (ceiling fan)</th>
                <th>Occupancy</th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td>Room 1</td>
                <td>Trivandrum</td>
                <td>First</td>
                <td>North</td>
                <td>V2</td>
                <td>on</td>
                <td>Double</td>
              </tr>
              <tr>
                <td>Room 2</td>
                <td>Thrissur</td>
                <td>First</td>
                <td>East</td>
                <td>V3</td>
                <td>on</td>
                <td>Double</td>
              </tr>
              <tr>
                <td>Room 3</td>
                <td>Thrissur</td>
                <td>First</td>
                <td>South</td>
                <td>V1</td>
                <td>on</td>
                <td>Single</td>
              </tr>
              <tr>
                <td>Room 4</td>
                <td>Trivandrum</td>
                <td>Ground</td>
                <td>North</td>
                <td>V2</td>
                <td>on</td>
                <td>Single</td>
              </tr>
              <tr>
                <td>Room 5</td>
                <td>Kochi</td>
                <td>Second</td>
                <td>East</td>
                <td>V1</td>
                <td>on</td>
                <td>Single</td>
              </tr>
              <tr>
                <td>Room 6</td>
                <td>Trivandrum</td>
                <td>First</td>
                <td>South</td>
                <td>V4</td>
                <td>on</td>
                <td>Single</td>
              </tr>
              <tr>
                <td>Room 7</td>
                <td>Kochi</td>
                <td>Second</td>
                <td>South</td>
                <td>V1</td>
                <td>on</td>
                <td>Single</td>
              </tr>
              <tr>
                <td>Room 8</td>
                <td>Kochi</td>
                <td>Third</td>
                <td>North</td>
                <td>V4</td>
                <td>on</td>
                <td>Single</td>
              </tr>
              <tr>
                <td>Room 9</td>
                <td>Kannur</td>
                <td>Ground</td>
                <td>East</td>
                <td>V1</td>
                <td>on</td>
                <td>Single</td>
              </tr>
              <tr>
                <td>Room 10</td>
                <td>Kannur</td>
                <td>Second</td>
                <td>West</td>
                <td>V4</td>
                <td>on</td>
                <td>Single</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
      <sec id="sec4">
        <title>Environmental Monitoring and Thermal Comfort Assessment</title>
        <p>Night-time environmental conditions were monitored using a Lutron WBGT-2010SD data logger and a Testo Smart Meter. Air temperature, relative humidity, carbon dioxide (CO₂) concentration, and air velocity were recorded during the sleeping period to characterise the bedroom thermal microclimate. Environmental and sleep data were synchronised for each monitored night to facilitate comparative analysis.</p>
        <fig id="fig1">
          <label>Figure 1</label>
          <caption><p>Testo Smart Meter used to measure indoor air temperature, relative humidity, and air velocity.</p></caption>
          <graphic xlink:href="obj/fa/b1/fab15270b3cad021d5a0f42ef64a7f8bf7a4d5e98d41a3418fc646fd1b14dbdb"/>
        </fig>
        <fig id="fig2">
          <label>Figure 2</label>
          <caption><p>WBGT meter used to periodically measure air temperature, globe temperature, relative humidity, and wet bulb globe temperature in the surveyed bedrooms during night-time field measurements.</p></caption>
          <graphic xlink:href="obj/de/0c/de0c2a792f72990c8cb28711630cfa5bae67cc3a5caed1a1ebb45a08cc900e5a"/>
        </fig>
        <table-wrap id="tbl3">
          <label>Table 3</label>
          <caption><p>Measured indoor environmental and occupant-related parameters for each surveyed bedroom.</p></caption>
          <table>
            <thead>
              <tr>
                <th><bold>Room</bold></th>
                <th><bold>Location</bold></th>
                <th><bold>Age Group (years)</bold></th>
                <th><bold>Met value</bold></th>
                <th><bold>Air temperature Ta (°C)</bold></th>
                <th><bold>Relative Humidity (%)</bold></th>
                <th><bold>Clo value</bold></th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td>R1</td>
                <td>Trivandrum</td>
                <td>36–50</td>
                <td>0.85</td>
                <td>27.8</td>
                <td>79</td>
                <td>0.4</td>
              </tr>
              <tr>
                <td>R2</td>
                <td>Thrissur</td>
                <td>36–50</td>
                <td>0.85</td>
                <td>28.4</td>
                <td>82</td>
                <td>0.4</td>
              </tr>
              <tr>
                <td>R3</td>
                <td>Thrissur</td>
                <td>24–35</td>
                <td>0.90</td>
                <td>26.9</td>
                <td>75</td>
                <td>0.4</td>
              </tr>
              <tr>
                <td>R4</td>
                <td>Trivandrum</td>
                <td>36–50</td>
                <td>0.85</td>
                <td>28.6</td>
                <td>83</td>
                <td>0.4</td>
              </tr>
              <tr>
                <td>R5</td>
                <td>Trivandrum</td>
                <td>24–35</td>
                <td>0.90</td>
                <td>26.2</td>
                <td>72</td>
                <td>0.4</td>
              </tr>
              <tr>
                <td>R6</td>
                <td>Trivandrum</td>
                <td>36–50</td>
                <td>0.85</td>
                <td>28.8</td>
                <td>84</td>
                <td>0.4</td>
              </tr>
              <tr>
                <td>R7</td>
                <td>Kochi</td>
                <td>24–35</td>
                <td>0.90</td>
                <td>26.6</td>
                <td>74</td>
                <td>0.4</td>
              </tr>
              <tr>
                <td>R8</td>
                <td>Kochi</td>
                <td>36–50</td>
                <td>0.85</td>
                <td>28.3</td>
                <td>81</td>
                <td>0.4</td>
              </tr>
              <tr>
                <td>R9</td>
                <td>Kannur</td>
                <td>24–35</td>
                <td>0.90</td>
                <td>25.9</td>
                <td>70</td>
                <td>0.4</td>
              </tr>
              <tr>
                <td>R10</td>
                <td>Kannur</td>
                <td>36–50</td>
                <td>0.85</td>
                <td>28.5</td>
                <td>83</td>
                <td>0.4</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
        <p>Thermal comfort was evaluated using the Predicted Mean Vote (PMV) model developed by Fanger and implemented through the CBE Thermal Comfort Tool, following the procedures outlined in ISO 7730 (<xref ref-type="bibr" rid="ref-89f65444-9d5c-4330-a208-a84fcea29a81">ISO 2005</xref>) and ASHRAE Standard 55 (<xref ref-type="bibr" rid="ref-d34dbb80-97cb-4315-a39b-b0546fff4a0e">ASHRAE 2023</xref>). PMV calculations incorporated measured environmental variables together with sleeping-specific assumptions, including a metabolic rate of approximately 0.7 met and clothing/bedding insulation representative of typical sleeping conditions.</p>
        <table-wrap id="tbl4">
          <label>Table 4</label>
          <caption><p>Corresponding PMV values from CBE thermal comfort tool.</p></caption>
          <table>
            <thead>
              <tr>
                <th><bold>Room</bold></th>
                <th><bold>Vent Class</bold></th>
                <th><bold>Air Speed (m/s)</bold></th>
                <th><bold>PMV</bold></th>
                <th><bold>Thermal Sensation</bold></th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td>R1</td>
                <td>V2</td>
                <td>0.20</td>
                <td>1.38</td>
                <td>Warm</td>
              </tr>
              <tr>
                <td>R2</td>
                <td>V3</td>
                <td>0.15</td>
                <td>1.62</td>
                <td>Warm</td>
              </tr>
              <tr>
                <td>R3</td>
                <td>V1</td>
                <td>0.35</td>
                <td>1.05</td>
                <td>Slightly warm</td>
              </tr>
              <tr>
                <td>R4</td>
                <td>V2</td>
                <td>0.20</td>
                <td>1.55</td>
                <td>Warm</td>
              </tr>
              <tr>
                <td>R5</td>
                <td>V1</td>
                <td>0.35</td>
                <td>0.92</td>
                <td>Near neutral to slightly warm</td>
              </tr>
              <tr>
                <td>R6</td>
                <td>V4</td>
                <td>0.10</td>
                <td>1.78</td>
                <td>Very warm</td>
              </tr>
              <tr>
                <td>R7</td>
                <td>V1</td>
                <td>0.35</td>
                <td>1.00</td>
                <td>Slightly warm</td>
              </tr>
              <tr>
                <td>R8</td>
                <td>V4</td>
                <td>0.10</td>
                <td>1.70</td>
                <td>Warm to very warm</td>
              </tr>
              <tr>
                <td>R9</td>
                <td>V1</td>
                <td>0.35</td>
                <td>0.85</td>
                <td>Near neutral</td>
              </tr>
              <tr>
                <td>R10</td>
                <td>V4</td>
                <td>0.10</td>
                <td>1.72</td>
                <td>Warm to very warm</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
      <sec id="sec5">
        <title>Sleep Quality Assessment</title>
        <p>Objective sleep quality was assessed using smart watch-based sleep tracking. Participants record their average sleep statistics from the past week, as tracked by their smart watch. This includes total sleep duration, the amount of time spent in REM, deep, and light sleep, sleep efficiency percentage, average sleep and wake times, and the number of awakenings per night. These objective measures provide a more accurate picture of sleep quality than self-reports alone.</p>
        <fig id="fig3">
          <label>Figure 3</label>
          <caption><p>Sleep cycle duration as measured by smart watch as shown in the respective android app, provided by the respondents.</p></caption>
          <graphic xlink:href="obj/40/25/4025d74350c28fdcc92ec714ca94513ae545b8d5f9b18d2da832e822e18ca61f"/>
        </fig>
        <table-wrap id="tbl5">
          <label>Table 5</label>
          <caption><p>Sleep cycle duration as measured by smart watch as shown in the respective android app, provided by the respondents.</p></caption>
          <table>
            <thead>
              <tr>
                <th>Cases</th>
                <th>Age group</th>
                <th>Total sleep duration(hrs)</th>
                <th>Deep sleep(hrs)</th>
                <th>Light sleep (hrs)</th>
                <th>REM sleep(hrs)</th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td>Room 1</td>
                <td>36–50</td>
                <td>6</td>
                <td>0.6</td>
                <td>3.48</td>
                <td>1.92</td>
              </tr>
              <tr>
                <td>Room 2</td>
                <td>36–50</td>
                <td>6</td>
                <td>0.36</td>
                <td>3.96</td>
                <td>1.68</td>
              </tr>
              <tr>
                <td>Room 3</td>
                <td>24–35</td>
                <td>6.5</td>
                <td>0.78</td>
                <td>3.58</td>
                <td>2.15</td>
              </tr>
              <tr>
                <td>Room 4</td>
                <td>36–50</td>
                <td>6</td>
                <td>0.48</td>
                <td>3.72</td>
                <td>1.8</td>
              </tr>
              <tr>
                <td>Room 5</td>
                <td>24–35</td>
                <td>6.5</td>
                <td>0.98</td>
                <td>3.25</td>
                <td>2.28</td>
              </tr>
              <tr>
                <td>Room 6</td>
                <td>36–50</td>
                <td>6</td>
                <td>0.36</td>
                <td>3.96</td>
                <td>1.68</td>
              </tr>
              <tr>
                <td>Room 7</td>
                <td>24–35</td>
                <td>6.5</td>
                <td>0.98</td>
                <td>3.25</td>
                <td>2.28</td>
              </tr>
              <tr>
                <td>Room 8</td>
                <td>36–50</td>
                <td>6</td>
                <td>0.36</td>
                <td>3.96</td>
                <td>1.68</td>
              </tr>
              <tr>
                <td>Room 9</td>
                <td>24–35</td>
                <td>6.5</td>
                <td>0.98</td>
                <td>3.25</td>
                <td>2.28</td>
              </tr>
              <tr>
                <td>Room 10</td>
                <td>36–50</td>
                <td>6</td>
                <td>0.36</td>
                <td>3.96</td>
                <td>1.68</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
        <p>Subjective sleep quality was evaluated using the Pittsburgh Sleep Quality Index (PSQI), a validated self-administered questionnaire developed by <xref ref-type="bibr" rid="ref-fbc7dbe7-8664-48ce-acea-d15c1b7ccc27">Buysse <italic>et al.</italic> (1989)</xref>. The PSQI evaluates sleep quality over the previous month through 19 self-rated items, which are grouped into seven components: subjective sleep quality, sleep latency, sleep duration, habitual sleep efficiency, sleep disturbances, use of sleeping medication, and daytime dysfunction.</p>
        <p>Each component is scored on a 0–3 scale, where 0 indicates no difficulty and 3 indicates severe difficulty. The seven component scores are summed to obtain a global PSQI score ranging from 0 to 21, with lower scores representing better sleep quality. A global score of ≤5 indicates good sleep quality, whereas a score of &gt;5 indicates poor sleep quality.</p>
        <table-wrap id="tbl6">
          <label>Table 6</label>
          <caption><p>PSQI score and its implications.</p></caption>
          <table>
            <thead>
              <tr>
                <th>Total PSQI Score</th>
                <th>Description</th>
                <th>Implication</th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td>0–4</td>
                <td>Good sleep quality</td>
                <td>Normal, healthy sleep patterns</td>
              </tr>
              <tr>
                <td>5–9</td>
                <td>Poor sleep quality</td>
                <td>Some sleep problems, not severe</td>
              </tr>
              <tr>
                <td>10–14</td>
                <td>Moderately Poor Sleep</td>
                <td>Noticeable sleep issues that may affect daytime functioning</td>
              </tr>
              <tr>
                <td>15–21</td>
                <td>Severe Sleep Problems</td>
                <td>Significant, likely chronic sleep disturbance</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
        <p>The findings from the participants were tabulated as follows:</p>
        <table-wrap id="tbl7">
          <label>Table 7</label>
          <caption><p>The observations from the participants and their respective PSQI scores.</p></caption>
          <table>
            <thead>
              <tr>
                <th>Cases</th>
                <th>Age group</th>
                <th>Total sleep duration(hrs)</th>
                <th>Sleep quality</th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td>Room 1</td>
                <td>36–50</td>
                <td>6</td>
                <td>Mild disturbance</td>
              </tr>
              <tr>
                <td>Room 2</td>
                <td>36–50</td>
                <td>6</td>
                <td>Moderate disturbance</td>
              </tr>
              <tr>
                <td>Room 3</td>
                <td>24–35</td>
                <td>6.5</td>
                <td>Near good</td>
              </tr>
              <tr>
                <td>Room 4</td>
                <td>36–50</td>
                <td>6</td>
                <td>Mild disturbance</td>
              </tr>
              <tr>
                <td>Room 5</td>
                <td>24–35</td>
                <td>6.5</td>
                <td>Good sleep</td>
              </tr>
              <tr>
                <td>Room 6</td>
                <td>36–50</td>
                <td>6</td>
                <td>Moderate-severe</td>
              </tr>
              <tr>
                <td>Room 7</td>
                <td>24–35</td>
                <td>6.5</td>
                <td>Good sleep</td>
              </tr>
              <tr>
                <td>Room 8</td>
                <td>36–50</td>
                <td>6</td>
                <td>Moderate</td>
              </tr>
              <tr>
                <td>Room 9</td>
                <td>24–35</td>
                <td>6.5</td>
                <td>Very good</td>
              </tr>
              <tr>
                <td>Room 10</td>
                <td>36–50</td>
                <td>6</td>
                <td>Moderate-severe</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
      <sec id="sec6">
        <title>Data Analysis</title>
        <p>The monitored environmental parameters were analysed alongside PMV values, smart watch-derived sleep metrics, and PSQI scores to identify relationships between bedroom thermal microclimates and sleep quality. Comparative analyses were performed across different ventilation categories and residential settings to evaluate the influence of thermal conditions on deep sleep duration and perceived sleep quality.</p>
        <fig id="fig4">
          <label>Figure 4</label>
          <caption><p>The scatter plot illustrates the relationship between predicted mean vote (PMV) and deep sleep duration for the ten surveyed bedrooms.</p></caption>
          <graphic xlink:href="obj/c5/06/c50668b7749eaad98d2bacd28b940e10833a76274c3b951aa409210db80516fe"/>
        </fig>
        <p>The scatter plot indicates a distinct negative association, where increasing PMV values correspond to progressively shorter deep sleep durations. Bedrooms with PMV values closer to thermal neutrality (0.85–1.00) consistently exhibited longer deep sleep durations, whereas rooms with higher PMV values (&gt;1.50), representing warmer thermal conditions, showed a marked reduction in deep sleep.</p>
        <table-wrap id="tbl8">
          <label>Table 8</label>
          <caption><p>Relationship between PMV and deep sleep duration.</p></caption>
          <table>
            <thead>
              <tr>
                <th><bold>PMV Range</bold></th>
                <th><bold>Deep Sleep Duration (h)</bold></th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td>0.85–1.00 (V1 rooms)</td>
                <td>0.98</td>
              </tr>
              <tr>
                <td>1.05–1.38</td>
                <td>0.60–0.78</td>
              </tr>
              <tr>
                <td>1.55–1.62</td>
                <td>0.36–0.48</td>
              </tr>
              <tr>
                <td>≥1.70 (V4 rooms)</td>
                <td>0.36</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
        <p>Overall, the scatter plot demonstrates that deep sleep duration decreases as PMV increases, highlighting the importance of maintaining bedroom conditions closer to thermal neutrality during the night. The findings also emphasize that passive design strategies such as effective cross-ventilation can improve thermal comfort and contribute to healthier sleep in naturally ventilated residential buildings in Kerala.</p>
      </sec>
    </sec>
    <sec id="sec7">
      <title>Results and discussion</title>
      <p>The results obtained from environmental monitoring and sleep assessments were analysed to investigate the relationship between bedroom thermal microclimates and sleep quality in diverse residential settings across Kerala. The observed relationship is also consistent with thermal comfort theory. As PMV increases above the comfort range, occupants experience greater thermal stress, leading to physiological responses such as increased perspiration, elevated skin temperature, and more frequent sleep disturbances. These responses can reduce the duration of slow-wave (deep) sleep, which is the most restorative stage of the sleep cycle.</p>
      <p>The present results therefore support the research indicating that warmer sleeping environments negatively affect sleep architecture by reducing deep sleep while increasing the likelihood of fragmented sleep. The findings contribute empirical evidence to support the integration of sleep-oriented thermal comfort considerations into residential building design and provide a basis for future research involving larger sample sizes, seasonal investigations, and a broader range of residential typologies to further strengthen climate-responsive housing design guidelines.</p>
    </sec>
  </body>
  <back>
    <fn-group>
      <fn fn-type="con"><p>Anagha Ashok: Conceptualization, Methodology, Investigation, Formal analysis, Data curation, Writing (original draft), Visualization, Validation, Software, Resources, Writing (review and editing). Deepa Rani R: Conceptualization, Methodology, Writing (review and editing), Supervision, Resources, Software, Project administration.</p></fn>
      <fn fn-type="conflict"><p>The authors declare no competing interests.</p></fn>
      <fn fn-type="data-availability"><p>All data generated or analysed during this study are included in this paper.</p></fn>
    </fn-group>
    <ref-list>
      <ref id="ref-4c6ae84c-0366-45f8-bd35-3a80f134f378">
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <string-name>Akimoto, Mizuho</string-name>
            <string-name>Fan, Xiaojun</string-name>
            <string-name>Lan, Li</string-name>
            <string-name>Sekhar, Chandra</string-name>
            <string-name>Tanabe, Shin-ichi</string-name>
            <string-name>Wyon, David P.</string-name>
            <string-name>Wargocki, Pawel</string-name>
          </person-group>
          <article-title>New research on bedroom ventilation and sleep quality suggests that building standards should be revisited (ASHRAE 1837-RP)</article-title>
          <source>Science and Technology for the Built Environment</source>
          <year>2025</year>
          <volume>31</volume>
          <issue>8</issue>
          <page-range>905-916</page-range>
          <publisher-name>Informa UK Limited</publisher-name>
          <pub-id pub-id-type="doi">10.1080/23744731.2025.2531317</pub-id>
        </element-citation>
      </ref>
      <ref id="ref-d34dbb80-97cb-4315-a39b-b0546fff4a0e">
        <element-citation publication-type="report">
          <person-group person-group-type="author">
            <string-name>ASHRAE</string-name>
          </person-group>
          <article-title>ANSI/ASHRAE Standard 55-2023: Thermal Environmental Conditions for Human Occupancy</article-title>
          <year>2023</year>
          <publisher-name>Atlanta, GA: ASHRAE</publisher-name>
        </element-citation>
      </ref>
      <ref id="ref-fbc7dbe7-8664-48ce-acea-d15c1b7ccc27">
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <string-name>Buysse, Daniel J.</string-name>
            <string-name>Reynolds, Charles F.</string-name>
            <string-name>Monk, Timothy H.</string-name>
            <string-name>Berman, Susan R.</string-name>
            <string-name>Kupfer, David J.</string-name>
          </person-group>
          <article-title>The Pittsburgh sleep quality index: A new instrument for psychiatric practice and research</article-title>
          <source>Psychiatry Research</source>
          <year>1989</year>
          <volume>28</volume>
          <issue>2</issue>
          <page-range>193-213</page-range>
          <publisher-name>Elsevier BV</publisher-name>
          <pub-id pub-id-type="doi">10.1016/0165-1781(89)90047-4</pub-id>
        </element-citation>
      </ref>
      <ref id="ref-9def411f-4f3e-42b9-bbc3-22648f2776fd">
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <string-name>Fan, Xiaojun</string-name>
            <string-name>Liao, Chenxi</string-name>
            <string-name>Matsuo, Kazuya</string-name>
            <string-name>Verniers, Kevin</string-name>
            <string-name>Laverge, Jelle</string-name>
            <string-name>Neyrinck, Brecht</string-name>
            <string-name>Pollet, Ivan</string-name>
            <string-name>Fang, Lei</string-name>
            <string-name>Lan, Li</string-name>
            <string-name>Sekhar, Chandra</string-name>
            <string-name>Wargocki, Pawel</string-name>
          </person-group>
          <article-title>A single-blind field intervention study of whether increased bedroom ventilation improves sleep quality</article-title>
          <source>Science of The Total Environment</source>
          <year>2023</year>
          <volume>884</volume>
          <page-range>163805</page-range>
          <publisher-name>Elsevier BV</publisher-name>
          <pub-id pub-id-type="doi">10.1016/j.scitotenv.2023.163805</pub-id>
        </element-citation>
      </ref>
      <ref id="ref-9d2cb8f0-fadb-49ed-8bda-d2e22658623a">
        <element-citation publication-type="book">
          <person-group person-group-type="author">
            <string-name>Fanger</string-name>
            <string-name>P.O.</string-name>
          </person-group>
          <article-title>Thermal Comfort: Analysis and Applications in Environmental Engineering</article-title>
          <year>1970</year>
          <publisher-name>Copenhagen: Danish Technical Press</publisher-name>
        </element-citation>
      </ref>
      <ref id="ref-89f65444-9d5c-4330-a208-a84fcea29a81">
        <element-citation publication-type="report">
          <person-group person-group-type="author">
            <string-name>ISO</string-name>
          </person-group>
          <article-title>ISO 7730: Ergonomics of the Thermal Environment—Analytical Determination and Interpretation of Thermal Comfort Using Calculation of the PMV and PPD Indices and Local Thermal Comfort Criteria</article-title>
          <year>2005</year>
          <publisher-name>3rd edn. Geneva: International Organization for Standardization</publisher-name>
        </element-citation>
      </ref>
      <ref id="ref-aeef8003-7fec-4b46-9f55-04a1ffcfcfa7">
        <element-citation publication-type="journal">
          <person-group person-group-type="author">
            <string-name>Okamoto-Mizuno, Kazue</string-name>
            <string-name>Mizuno, Koh</string-name>
          </person-group>
          <article-title>Effects of thermal environment on sleep and circadian rhythm</article-title>
          <source>Journal of Physiological Anthropology</source>
          <year>2012</year>
          <volume>31</volume>
          <issue>1</issue>
          <publisher-name>Springer Science and Business Media LLC</publisher-name>
          <pub-id pub-id-type="doi">10.1186/1880-6805-31-14</pub-id>
        </element-citation>
      </ref>
    </ref-list>
  </back>
</article>