This paper illustrates an integrated energy design model based on the energy balance of a single zone. The results of energy efficient residential building design for the different climate zones of China by implementing an integrated energy model have been presented. Optimum measures of building design for typical Chinese residential buildings are introduced, with the objective of minimizing annual energy consumption for those buildings and improving thermal comfort. One overriding conclusion is that significant energy savings and thermal comfort can be achieved though optimum design.
Keywords. energy efficiency; residential building; China; climate zones
References
Nick Baker and Koen Steemers, 1999, LT 2.1 in Energy and Environment in Architecture, E&FN Spon, Taylor Francis Group, London.
Nick Baker & Runming Yao, 2002, LT—Europe an Integrated Energy Design Tool for Building, PLEA 2002, Toulouse, France.
Runming Yao, Nick Baker and Mike McEvoy, 2002, A Simplified Thermal Resistance Network Model for Building Thermal Simulation, Sim2002, Proceedings of eSim, Montreal, Canada.
Chinese Standard,(1996) Energy Conservation Design Standard for New Heating Residential Buildings, JGJ 26-95 , Chinese Construction Industry Publisher,Beijing
Chinese Standard, 2001, Design Standard for Energy Efficiency of Residential Buildings in Hot Summer and Cold Winter Zone. JGJ 134-2001, J116-2001, Chinese Construction Industry Publisher, Beijing
Chinese Standard, 1993, Thermal Design Code for Civil Building, Chinese Planning Publisher, Beijing
Chinese Academy of Building Research, 1965, "Cooling Building In Hot District" (in Chinese), China's Industrial Publishing House, China
How to cite this article
Yao, R., Steemers, K. and Li, B. (2003). 'Energy efficient design for residential buildings in China'. SET Proceedings, 2(1), pp. 41-45. https://doi.org/10.65582/set.2003.008