Numerical Analysis of Thermal Environments Achieved by Different Indoor-Unit Types of Decentralized Air-Conditioner in South Korean Residential Buildings
, ,
1Department of Architecture, Yeungnam University, Gyeongsan, Gyeongbuk, South Korea
2School of Architecture, Yeungnam University, Gyeongsan, Gyeongbuk, South Korea
This research was conducted as a fundamental study in presenting efficient installation standards for decentralized air-conditioning systems in residential buildings. Ergo, the study observed the current status and issues of residential air-conditioning in South Korea and selected the most commonly used indoor package air-conditioning system types. Then CFD numerical analysis was performed to compare and analyze the indoor thermal environment achieved by each type of package air-conditioning system.
Keywords. thermal environment; indoor air-conditioning unit; residential building
How to cite this article
Kim, D., Yang, J. and Seok, H. (2008). 'Numerical Analysis of Thermal Environments Achieved by Different Indoor-Unit Types of Decentralized Air-Conditioner in South Korean Residential Buildings'. SET Proceedings, 7(1), pp. 999-1006. https://doi.org/10.65582/set.2008.132