Refrigerator Coupling to a Water-Heater and Heating Floor to Save Energy and to Reduce Carbon Emissions

1ISSAT Gabes Route de Médenine 6029 Gabes Tunisia

Published
2 September 2012
Pages
1241-1252
Received
2 September 2012
DOI
10.65582/set.2012.128
Access
Open access, © 2012 Copyright WSSET
Download PDF12 pages · 691 KB

Abstract

With an aim of rationally energy use and to reduce carbon emission, our interest was directed towards the refrigerators and all the refrigerating machines. Indeed the heat yielded by the exchanger condenser can be developed for the water heating, floors heating etc. After an encouraging theoretical study, two prototypes were produced in order to validate the theoretical results. A first refrigerator was coupled with a water-heater and another with a heating floor. The water temperature reached, in one day, is of 60 °C; which makes it possible to predict better results with a continuously used refrigerator. In the same way for the heating floor coupled with the second refrigerator, the temperature reached high values because the surface is reduced; however for the heating floors the standard fixes the temperature between 28 and 30 °C.

Keywords. Refrigerator; recuperator; heating water; heating floor; heat pump