Existing metrics, codes and technologies for HVAC design of energy-efficient data centre: A literature review

, , ,

1School of Engineering, University of Hull, UK, HU6 7RX

2China Academy of Building Research Southwest Institute, China

3Department of Architecture and Building Environment, University of Nottingham, UK

Published
6 July 2016
Pages
601-611
Received
6 July 2016
DOI
10.65582/set.2015.146
Access
Open access, © 2015 Copyright WSSET
Download PDF11 pages · 776 KB

Abstract

The data centre energy demand increased rapidly because the explosion of IT industry, and the annual increasing rate will keep as high as 20% in the predictable future. Until 2013, there are over 1000 large colocation data centres from 24 countries in EU and 562 from China, taken 1.3% and 1.2% energy from the whole social energy consumption respectively. However, in a typical EU data centre, 40% energy is used for HAVC and 10% is relevant to the building itself, both of which have a huge energy saving potential by applying advanced HAVC technologies and proper building design strategies. This paper reviewed the codes and standards for energy-efficient data centre, as well as relevant techniques in term of data centre HVAC system design. The most widely used data centre energy efficacy metrics and benchmarks are studies, the requirements of codes from main countries are compared and analysed, such as Chinese “DB31/651-2012: The norm of Data centre Unit Energy Effectiveness” and “The EU Code of Conduct on Data Centres”. Meanwhile, a number of data centre adoptable energy saving system (mainly represent by cooling system) are investigated. By investigation and comparison of metrics, code and techniques mainly including cooling and energy recovery, the energy efficiency requirements emphasis and the features of available energy saving techniques for data centre are summarised in this paper. Although the code requirement is higher and higher, and the technologies are keep improving, obvious shortcomings still exist in sustainability and economic aspects which are discussed in the end of this review.

Keywords. Energy efficiency; Data centre; Building service; HVAC; codes; metrics; techniques

© 2015 Copyright WSSET

Free to read, download, print and share, unaltered and for non-commercial purposes, provided the authors, the paper and the proceedings are credited. Any other use, including commercial use or adaptation, needs written permission: write to [email protected].

← SET Proceedings