Skip to content
Caravel Press

Conference paper

Experimental studies of a pulse pressurisation technique for measuring building airtightness

, , , , , ,

1Architecture, Energy and Environment Research Group, Faculty of Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, UK

2Department of Mechanics and Engineering Science, Fudan University 220 Handan Road, Shanghai, China

Published
28 February 2019
Pages
103-114
Received
28 February 2019
DOI
10.65582/set.2018.012
Access
Open access, © 2018 Copyright WSSET
Download PDF12 pages · 1.1 MB

Abstract

A pulse pressurisation technique is developed and utilised for determining building leakage at low pressure, based on a ‘quasi-steady pulse’ concept. The underlying principle of the technique is to subject the building envelope to a known volume change in a short period of time (typically 1.5 s). The resulting pressure pulse is recorded, from which the leakage characteristic at low pressure is determined. The technique minimizes the effects of wind and buoyancy forces and has proven to be repeatable. It can employ a compact and portable test rig and does not need to penetrate the building envelope. Therefore, it can establish the leakage of a building very quickly and efficiently. Throughout the various stages of research and development of the pulse technique, experimental investigations have been carried out under different configurations and scenarios in order to validate the changes that have been made for the purpose of system development and optimisation. This paper provides an overview of experimental investigations in the validation process by covering comparison between blower door and pulse unit, comparison between piston-based pulse unit and nozzle-based pulse unit, testing with multiple pulse units in a large building, testing with a known opening, and testing in different building types with a range of volumes and airtightness levels. It enables us to understand the strengths and also the limits of the pulse technique, from the experimental and practical perspective.

Keywords. Building airtightness; Blower door; Pulse technique; Experimental validation

© 2018 Copyright WSSET

Free to read, download, print and share, unaltered and for non-commercial purposes, provided the authors, the paper and the proceedings are credited. Any other use, including commercial use or adaptation, needs written permission: write to [email protected].

← SET Proceedings