Worldwide, approximately 25-30% of electricity is consumed by air conditioning and refrigeration systems therefore energy efficiencies of these systems are very important. Much research on HVAC should be performed in order to increase the efficiency of these systems. In this study, an air-to-air heat pump for cooling purposes using R404A was observed. The entropy generations of the elements of air-to-air heat pump were experimentally carried out in terms of surrounding air temperatures between 25°C to 30°C. In addition, a computer program was improved by means of Engineering Equation Solver (EES) for this purpose; temperatures, pressures, and the power delivered to the compressor and the blowers were also measured. As the surrounding air temperature increased, the entropy generation in the compressor, outdoor unit, and indoor unit increased while the entropy generation in the capillary tube decreased. The maximum entropy generation was obtained in the compressor. Entropy generation of the compressor increased from 0.003026 kW/K to 0.003172 kW/K.
Keywords. heat pump; entropy generation; R404A
References
Akhilesh, A., Kaushik, S. C., 2017. Theoretical analysis of a vapour compression refrigeration system with R502, R404A and R507A. International Journal of Refrigeration, 31, 998-1005.
Bukola, O. B., 2011. Performance investigation of ozone-friendly R404A and R507 refrigerants as alternatives to R22 in a window air-conditioner. Energy and Buildings, 43, 3139-3143.
Ehsan, A. R., Saeed, M., 2019. Entropic optimization of the economizer’s pressure in a heat pump cycle integrated with a flash-tank and vapor-injection system. International Journal of Refrigeration, 97, 56-66.
Kim, B.-J., Jo, S.-Y., & Jeong, J.-W. 2022. Energy performance enhancement in air-source heat pump with a direct evaporative cooler-applied condenser. Case Studies in Thermal Engineering,35, 102137.
Jin, L., Cao, F., Yang, D., Wang, X. 2016. Performance investigations of an R404A air-source heat pump with an internal heat exchanger for residential heating in northern China. International Journal of Refrigeration, 67, 239–248.
Yongcai, L., Wuyan, L., Zongsheng, L., Jun, L., Liyue, Z., Lulu, Y., Ling, X., 2017. Theoretical and numerical study on performance of the air-source heat pump system in Tibet. Renewable Energy, 114, 489-501.
How to cite this article
Tore, H. and Kiliçarslan, A. (2022). 'Entropy generation of the main components of an air source heat pump using 404A as a refrigerant'. SET Proceedings, 19(1), pp. 50-55. https://doi.org/10.65582/set.2022.008