The adoption of ventilated roofs and facades, as well as the integration of phase change materials (PCMs) in the building envelope, have proved to be effective as passive cooling techniques in reducing solar heat gain through the building envelope during the summer period and, therefore, reducing the energy requirement for cooling. Even though much research has focused on each of these strategies individually, their combination has not been deeply studied yet. Preliminary numerical studies were carried out on the application of PCMs on a pitched ventilated tiled roof and the most effective position turned out to be suspension in the middle of the above sheathing ventilation (ASV) channel. Based on this conclusion and exploiting an existing mock-up facility, two equivalent pitched ventilated roofs with an air gap of 4cm were built to cover two identical rooms, each one equipped with a fan coil; one with a 0.007m PCM layer suspended in the middle of the ASV and the other one without. They were then tested under real conditions at the TekneHub Laboratory at the University of Ferrara. The PCM supplied was an inorganic PCM with a melting temperature of 25°C and the roofs had a steel structure upon which a wooden deck covered by a polyolefin membrane was installed, with a cladding layer of Portuguese tiles. The behaviour of the two configurations were compared in terms of temperature, heat flux, velocity of the air in the ASV, and energy requirement for cooling, which were monitored through T-type thermocouples, heat flow meter, anemometers and energy meters, respectively. The aim of the research was to validate the numerical results and confirm that the combination of the two strategies allows further improvement of roof performance. Results showed consistent differences between the two configurations corresponding with the melting range of the PCM, which brought variances in the temperature of the extrados of the wooden deck of more than 5K and a reduction of the HVAC system operating time in the room with the PCM roof.
Keywords. passive cooling; phase change materials; ventilated roof; energy efficiency of buildings
References
Baccega, E., Bortoloni, M., Bottarelli, M., Dino, G.E., Zannoni, G. 2022. Improving the air permeability of ventilated roofs. Future Cities and Environment, 8(1), 1-8.
Boosting Building renovation, 2016. Available online: https://www.europarl.europa.eu/RegData/etudes/STUD/2016/587326/IPOL_STU(2016)587326_EN.pdf (accessed on 27 March 2022).
Bottarelli, M., Bortoloni, M., Zannoni, G., Allen, R., Cherry, N. 2017a. CFD analysis of roof tile coverings. Energy, 137, 391-398. http://dx.doi.org/10.1016/j.energy.2017.03.081
Bottarelli, M., Bortoloni, M. 2017b. On the heat transfer through roof tile coverings. International Journal of Heat and Technology, 35, 316-321. http://doi.org/10.1820/ijht.35Sp0143
Bottarelli, M., Bortoloni, M., Dino, G. 2018. Experimental analysis of an innovative tile covering for ventilated pitched roofs. International Journal of Low Carbon Technologies, 13, 6-14. http://dx.doi.org/10.1093/ijlct/ctx014
Bottarelli, M., González Gallero, J.F., Rodríguez Maestre, I., Pei, G., Su, Y. 2020. Solar gain mitigation in ventilated tiled roofs by using phase change materials. International Journal of Low Carbon Technologies, 00, 1-9. http://doi.org/10.1093/ijlct/ctaa001
Chan, H.Y., Riffat, S.B., Zhu, J. 2010. Review of passive solar heating and cooling technologies. Renewable and Sustainable Energy Reviews, 14, 781-789. http://doi.org/10.1016/j.rser.2009.10.030
Ciampi, M., Leccese, F., Tuoni, G. 2005. Energy analysis of ventilated and microventilated roofs. Solar Energy, 79, 183-192. http://doi.org/10.1016/j.solener.2004.08.014
COMSOL Multiphysics Reference Manual. Available online: http://www.comsol.com (accessed on 19 November 2020).
Dimoudi A., Androutsopoulos A., Lykoudis S. 2006. Summer performance of a ventilated roof component. Energy and Buildings, 38, 610-617. http://doi.org/10.1016/j.enbuild.2005.09.006
HEROTILE. https://www.lifeherotile.eu/it/
Hou, M., Kong, X., Li, H., Yang, H., Chen, W. 2021. Experimental study on the thermal performance of composite phase change ventilated roof. Journal of Energy Storage, 33. https://doi.org/10.1016/j.est.2020.102060
Kosny, J., Biswas, K., Miller, W., Kriner S. 2012. Field thermal performance of naturally ventilated solar roof with PCM heat sink. Solar Energy, 86, 2504-2514. http://dx.doi.org/10.1016/j.solener.2012.05.020
Lee, S., Park, S.H., Yeo, M.S., Kim, K.W. 2009. An experimental study on airflow in the cavity of a ventilated roof. Building and Environment, 44, 1431-1439. http://doi.org/10.1016/j.buildenv.2008.09.009
Lizana, J., Chacartegui, R., Barrios-Padura, A., Valverde, J.M. 2017. Advances in thermal energy storage materilas and their applications towards zero energy buildings: A critical review. Applied Energy, 203, 219-239. http://dx.doi.org/10.1016/j.apenergy.2017.06.008
Masters, G.M. 2004. Renewable and Efficient Electric Power Systems. New York: John Wiley and Sons.
Song, Y., Darani, K.S., Khdair, A.I., Abu-Rumman, G., Kalbasi, R. 2021. A review on conventional passive cooling methods applicable to arid and warm climates considering economic cost and efficiency analysis in resource-based cities. Energy Reports, 7, 2784-2820. https://doi.org/10.1016/j.egyr.2021.04.056
Ürge-Vorsatz, D., Cabeza, L.F., Serrano, S., Barreneche, C., Petrichenko, K. 2015. Heating and cooling energy trends and drivers in buildings. Renewable and Sustainable Energy Reviews, 41, 85-98. http://dx.doi.org/10.1016/j.rser.2014.08.039
Yu, J., Leng, K., Wang, F., Ye, H., Luo, Y. 2020. Simulation study on dynamic thermal performance of a new ventilated roof with form stable PCM in Southern China. Sustainability, 12. http://doi.org/10.3390/su12229315
How to cite this article
Baccega, E., Bottarelli, M., González Gallero, F.J. and Zannoni, G. (2022). 'Improving energy efficiency of a ventilated tiled roof by using phase change materials'. SET Proceedings, 19(1), pp. 377-385. https://doi.org/10.65582/set.2022.043