Numerical investigation of barrier effect with air, argon and krypton gases in double glazing application

, ,

1Department of Architecture, Faculty of Engineering and Architecture, Recep Tayyip Erdogan University, Zihni Derin Campus, 53100 Rize, Turkey

2Department of Mechanical Engineering, Faculty of Engineering and Architecture, Recep Tayyip Erdogan University, Zihni Derin Campus, 53100 Rize, Turkey

3Low/Zero Carbon Energy Technologies Laboratory, Faculty of Engineering and Architecture, Recep Tayyip Erdogan University, Zihni Derin Campus, 53100 Rize, Turkey

Published
16 February 2023
Pages
398-405
Received
16 February 2023
DOI
10.65582/set.2022.133
Access
Open access, © 2022 Copyright WSSET
Download PDF8 pages · 606 KB

Abstract

In daily life, people spend a lot of time indoors. For this reason, it is important to design closed environments in such a way that they do not adversely affect human health. Especially temperature adjustment is one of these designs. The main goal is to keep indoor environments cool in the summer and warm in the winter. This study investigated window design, which is an important part of the indoor environments. Air, argon and krypton gases used in double glazing applications reduce the window heat transfer coefficient. In the study, a 2D CFD model was created and gas movement was prevented with a transparent barrier placed in a gas environment. In this way, convection effects were reduced and the heat transfer coefficient of the window was interpreted. In the reference state, the window heat transfer coefficient was determined for air, argon and krypton at a gas thickness of 20mm. Then, the gas movement was prevented by the transparent barrier and the new value of the window heat transfer coefficient was compared with the reference situation. It was seen that the window heat transfer coefficient, which was 1.605, 1.122 and 0.875 w/m2K for the 3 gases in the reference case, was 1.398, 0.956 and 0.687 W/m2K with the transparent barrier, respectively. In addition, when the velocities of the gases between the double glazing were considered, it was seen that the fluid velocity was higher for argon and krypton than for air when there was no obstruction. A similar situation was observed when a blocker was placed.

Keywords. double glazing; air-argon and krypton gas; thermal insulation; CFD