One of the necessities for exergy analysis is the correct choice of reference environment. The reference environment is very important in low-temperature exergy analyses because a slight temperature change can greatly affect the calculated values. In this research, a room in Tehran was simulated, and energy analysis performed. Following that, dynamic exergy analysis was performed with two approaches. In one approach, indoor air was defined as the reference environment, while in the other approach, outdoor air temperature was defined as the reference environment for exergy analysis. Conceptually, the outdoor air was an environment that was available for free and unlimited at any time. So, choosing outdoor air temperature as the reference environment for exergy analysis was more accurate, but it had more effort in exergy calculations. Exergy analysis was performed accordingly, and then the two approaches were compared. The comparison showed that in most of the modelling period, when the reference environment was chosen to be indoor, the calculated hourly exergy destruction was less than when the reference environment was outdoor. Results showed that, due to the simplification in choosing the indoor as the reference environment, the error of calculation of the hourly exergy destruction reached a maximum of 60%, high enough to avoid the simplification for dynamic exergy analysis. However, the results showed that calculations’ annually-averaged error was limited to 1.5%, an acceptable level for state exergy analysis.
Keywords. energy; exergy; dynamic; building; reference point
References
Bejan A., Tsatsaronis G., Moran M., 1996. Thermal design and optimization. John Wiley & Sons, Inc.
Dovjak M., Shukuya M., Krainer A., 2012. Exergy Analysis of Conventional and Low Exergy Systems for Heating and Cooling of Near Zero Energy Buildings. Journal of Mechanical Engineering.
Fütterer J., Constantin A., 2014. Energy concept for the E. ON ERC main building. E.ON Energy Research Center Series 4(9).
Fütterer J., Constantin A., Müller D., 2011. An energy concept for multifunctional buildings with geothermal energy and photovoltaic. In: Proceedings of CISBAT International Scientific Conference; Lausanne, Switzerland.
Kazanci O.B., Shukuya M., Olesen B.W., 2016. Exergy performance of different space heating systems: A theoretical study. Building and Environment.
Pu J., Liu G., Feng X., 2010. Application of the cumulative exergy approach to different air conditioning systems. Energy and Buildings.
Rosen M.A., Dincer I., 2004. Effect of varying dead-state properties on energy and exergy analyses of thermal systems. International Journal of Thermal Sciences.
Sakulpipatsin P., Itard L.C.M., van der Kooi H.J., Boelman E.C., Luscuere P.G., 2010. An exergy application for analysis of buildings and HVAC systems. Energy and Buildings.
Sakulpipatsin P., Van Der Kooi H.J., Itard L.C.M., Boelman E.C., 2008. The influence of possible definitions of a reference environment to determine the exergy of air in buildings. International Journal of Exergy.
Sayadi S, Tsatsaronis G, Morosuk T., 2016. A new approach for applying dynamic exergy analysis and exergoeconomics to a building envelope. In: ECOS 2016: proceedings of the 29th international conference on efficiency, cost, optimization, simulation and environmental impact of energy systems; 2016 June 19-23. p. 1–17. Portoroz, Slovenia.
Shukuya M., 2009. Exergy concept and its application to the built environment. Building and Environment.
Torio H., Angelotti A., Schmidt D., 2009. Exergy analysis of renewable energy-based climatisation systems for buildings: A critical view. Energy and Buildings.
Wei Z., Zmeureanu R., 2009. Exergy analysis of variable air volume systems for an office building. Energy Conversion and Management.
How to cite this article
Fallahpour, M.J. and Khajehpour, H. (2022). 'The effect of reference point selection on dynamics exergy analysis in buildings (Case study: Tehran)'. SET Proceedings, 19(4), pp. 91-97. https://doi.org/10.65582/set.2022.143