The intermittency and flexibility of heating systems with different terminal types in buildings

, , ,

1University of Nottingham, Nottingham NG7 2RD, United Kingdom

2North China Electric Power University, Beijing 102206, China

Published
15 December 2023
Pages
169-178
Received
15 December 2023
DOI
10.65582/set.2023.019
Access
Open access, © 2023 Copyright WSSET
Download PDF10 pages · 662 KB

Abstract

The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking central heating. As a major component of heating systems, heating terminals have great effect on both intermittency and flexibility of the system. In this study, an integrated dynamic model was developed by considering the interaction of thermal processes among building envelopes, terminals, and heat pumps. The radiant heat transfer ratio of the heating terminal, which was introduced in the dynamic thermal balance equations, was a key parameter to describe the characteristic of heat transfer between the terminal and the building. Field tests demonstrated that the simulated results were closer to the tested values when considering the proposed ratio. An intermittent heating control strategy as well as demand response operation were applied to heat pump heating systems respectively. The effect of different terminals on room temperature response speed, energy saving rate, load shifting rate and load shifting efficiency was analysed. The results indicated that heat pumps under intermittent heating were more efficient in buildings with convective heating terminals. Specifically, fan-coil heating systems could use 16.48% less energy, while radiant floor heating systems consumed more energy under intermittent heating. For buildings with convective terminals (such as fan coils), the warm-up time was 0.09 h to 0.33 h, and for those with convective-radiative terminals (such as radiators), the warm-up time was 0.23 h to 4 h under daily intermittent heating, while there was nearly no need to preheat in buildings with radiative terminals (such as radiant floors). On the other hand, the buildings with radiative heating terminals had better flexibility potential. By adopting the model predictive control strategy, the load shifting ratio of radiator heating systems was about 2.9 times that of fan coil heating systems. Finally, an idea of a novel radiation-adjustable heating terminal was proposed in order to achieve both intermittency and flexibility.

Keywords. Heating terminal; Radiant heat transfer ratio; Intermittent heating; Demand response; Load shifting ratio

© 2023 Copyright WSSET

Free to read, download, print and share, unaltered and for non-commercial purposes, provided the authors, the paper and the proceedings are credited. Any other use, including commercial use or adaptation, needs written permission: write to [email protected].

← SET Proceedings