Several studies show that the designed performance value of buildings may be dissimilar to the actual energy performance value. A large part of this performance criterion is due to the thermal resistance of the elements in the building envelope. The most frequently utilised technique for calculating the thermal performance of a real building is the co-heating test. It is an experimental method used to specify the heat loss coefficient (HLC) of an as-built of building. This determination emerges by determining and plotting the daily heat input against the indoor and outdoor temperature difference of the building. Also, it is a quasi-steady state method that can be calculated correctly for the whole dwelling HLC. This article covers the evaluation of the thermal insulation performance of residential buildings in the UK by using the co-heating test method. The aim of this study is to describe improvements in U-values of building envelopes at pre- and post-retrofit cases in the UK dwellings. The assessments are done over a wide range of building types with different structural and constructional features.
Keywords. Co-heating test; Energy performance; Envelope performance; Performance gap; Heat loss
References
Alexander, D. K., and Jenkins, H. G., 2015. The validity and reliability of co-heating tests made on highly insulated dwellings. Energy Procedia, 78, 1732-1737.
Alzetto, F., Farmer, D., Fitton, R., Hughes, T., and Swan, W., 2018. Comparison of whole house heat loss test methods under controlled conditions in six distinct retrofit scenarios. Energy and Buildings, 168, 35-41.
Cuce, E., Besir, A. B., and Cuce, P. M., 2018. Low/Zero-Carbon Buildings for a Sustainable Future. In Low Carbon Transition-Technical, Economic and Policy Assessment. IntechOpen. Available at: 10.5772/intechopen.74540 (Accessed: 10 July 2023).
Cuce, E., 2017. Role of airtightness in energy loss from windows: Experimental results from in-situ tests. Energy and Buildings, 139, 449-455.
Cuce, E., and Riffat, S. B., 2016. A comprehensive assessment of sectoral energy consumption in the UK: past, present and future. International Journal of Low-Carbon Technologies, 11(3), 424-430.
Cuce, E., and Cuce, P. M., 2016. The impact of internal aerogel retrofitting on the thermal bridges of residential buildings: An experimental and statistical research. Energy and Buildings, 116, 449-454.
Cuce, E., and Cuce, P. M., 2013. A comprehensive review on solar cookers. Applied Energy, 102, 1399-1421.
Deb, C., Gelder, L. V., Spiekman, M., Pandraud, G., Jack, R., and Fitton, R., 2021. Measuring the heat transfer coefficient (HTC) in buildings: A stakeholder's survey. Renewable and Sustainable Energy Reviews, 144, 111008.
Energy Saving Trust. Enhanced Construction Details: Thermal Bridging and Airtightness 2009. Available at: https://www.energysavingtrust.org.uk/sites/default/files/reports/CE302%20-%20ECD_thermal%20bridging%20and%20airtightness.pdf (Accessed: 10 July 2023).
Gupta, R., and Gregg, M., 2021. Integrated testing of building fabric thermal performance for calibration of energy models of three low-energy dwellings in the UK. Sustainability, 13(5), 2784.
Gupta, R., and Kotopouleas, A., 2018. Magnitude and extent of building fabric thermal performance gap in UK low energy housing. Applied Energy, 222, 673-686.
Jack, R., Loveday, D., Allinson, D., and Lomas, K., 2018. First evidence for the reliability of building co-heating tests. Building Research & Information, 46(4), 383-401.
Johnston, D., Miles-Shenton, D., Farmer, D., and Wingfield, J., 2013. Whole house heat loss test method (Coheating). Leeds Metropolitan University: Leeds, UK.
Johnston, D., Wingfield, J., and Miles-Shenton, D., 2010, September. Measuring the fabric performance of UK dwellings. In Proceedings of the Association of Researchers in Construction Management (ARCOM) Twenty-Sixth Annual Conference vol. 2, pp. 1371-1380.
Kim, S., Seo, J., Jeong, H., and Kim, J., 2022. In situ measurement of the heat loss coefficient of thermal bridges in a building envelope. Energy and Buildings, 256, 111627.
Parker, J., Farmer, D., Johnston, D., Fletcher, M., Thomas, F., Gorse, C., and Stenlund, S., 2019. Measuring and modelling retrofit fabric performance in solid wall conjoined dwellings. Energy and Buildings, 185, 49-65.
Riffat, S. B., and Cuce, E., 2011. A review on hybrid photovoltaic/thermal collectors and systems. International Journal of Low-Carbon Technologies, 6(3), 212-241.
Stamp, S., Lowe, R., and Altamirano-Medina, H., 2013. An investigation into the role of thermal mass on the accuracy of co-heating tests through simulations & field results.
Sutter, J. D., and Berlinger, J., 2015. Final draft of climate deal formally accepted in Paris. CNN. Cable News Network, 3, 3
How to cite this article
Cuce, E., Cuce, P.M. and Alvur, E. (2023). 'Thermal insulation performance assessment of UK dwellings through co-heating test methodology: A critical review'. SET Proceedings, 20(1), pp. 361-364. https://doi.org/10.65582/set.2023.040