Due to the lack of process and easy-to-learn system-level diagnosis methods for a chiller plant. The authors of this article presented an energy-saving diagnosis strategy for chiller plants to detect faults early and achieve sustainable built environments. This strategy analyses common weaknesses in building chilled water systems from maintenance, design, and operation perspectives. It comprises four steps: macroscopic energy efficiency index judgment, system troubleshooting, design diagnosis, and operation diagnosis. The authors applied the strategy to a typical hospital building in a hot and cold region of China. They found that partial-load conditions were a significant problem, reducing cooling efficiency and excess cooling in unoccupied rooms. The overall yearly energy efficiency (COPplant) was 3.27, and the useless energy consumption caused by this operation in 2021 is as high as 510327 kWh. A specific solution was proposed, including replacing the check valve, cleaning the condenser, and avoiding multiple water pumps with a small number of hosts. The authors also recommended developing a frequency conversion control strategy for the water pump under partial load and creating a chiller opening strategy at different load intervals of the building.
Keywords. Energy-saving; Fault detection; Chiller plant; Sustainability; Building Efficiency
References
bai, X., Zhang, M. X., Jin, Z. H., You, Y. L. & Liang, C. H. 2022. Fault detection and diagnosis for chiller based on feature-recognition model and Kernel Discriminant Analysis. Sustainable Cities and Society, 79.
Brambley, M., Pratt, R., Chassin, D., Katipamula, S. & Hatley, D. 1998. Diagnostics for outdoor air ventilation and economizers. Ashrae Journal-American Society of Heating Refrigerating and Air-Conditioning Engineers, 40, 49-+.
Chen, J. L., Zhang, L., Li, Y. F., Shi, Y. F., Gao, X. H. & Hu, Y. Q. 2022. A review of computing-based automated fault detection and diagnosis of heating, ventilation and air conditioning systems. Renewable & Sustainable Energy Reviews, 161.
Gunay, B., Bursill, J., Huchuk, B. & Shillinglaw, S. 2022. Inverse model-based detection of programming logic faults in multiple zone VAV AHU systems. Building and Environment, 211.
Han, S. Y., Shao, H. D., Huo, Z. Q., Yang, X. K. & Cheng, J. S. 2022. End-to-end chiller fault diagnosis using fused attention mechanism and dynamic cross-entropy under imbalanced datasets. Building and Environment, 212.
Huang, T., Liang, C., Bai, X., Feng, Z. & Wang, F. 2019. Study on the feature-recognition-based modeling approach of chillers. International Journal of Refrigeration-Revue Internationale Du Froid, 100, 326-334.
Li, G. N., Yao, Q., Fan, C., Zhou, C. L., Wu, G. H., Zhou, Z. X. & Fang, X. 2021. An explainable one-dimensional convolutional neural networks based fault diagnosis method for building heating, ventilation and air conditioning systems. Building and Environment, 203.
Li, H. R. & Li, X. F. 2018. Benchmarking energy performance for cooling in large commercial buildings. Energy and Buildings, 176, 179-193.
Lin, G. J. & Claridge, D. E. 2015. A temperature-based approach to detect abnormal building energy consumption. Energy and Buildings, 93, 110-118.
Lu, X., Fu, Y., O'neill, Z. & Wen, J. 2021. A holistic fault impact analysis of the high-performance sequences of operation for HVAC systems: Modelica-based case study in a medium-office building. Energy and Buildings, 252.
Ranade, A., Provan, G., Mady, A. E. D. & O'sullivan, D. 2020. A computationally efficient method for fault diagnosis of fan-coil unit terminals in building Heating Ventilation and Air Conditioning systems. Journal of Building Engineering, 27.
Rosato, A., Guarino, F., El Youssef, M., Capozzoli, A., Masullo, M. & Maffei, L. 2022. Faulty Operation of Coils' and Humidifier Valves in a Typical Air-Handling Unit: Experimental Impact Assessment of Indoor Comfort and Patterns of Operating Parameters under Mediterranean Climatic Conditions. Energies, 15.
Saidur, R. 2009. Energy consumption, energy savings, and emission analysis in Malaysian office buildings. Energy Policy, 37, 4104-4113.
Sun, B. A., Luh, P. B., Jia, Q. S., O'neill, Z. & Song, F. T. 2014. Building Energy Doctors: An SPC and Kalman Filter-Based Method for System-Level Fault Detection in HVAC Systems. Ieee Transactions on Automation Science and Engineering, 11, 215-229.
Torabi, N., Gunay, H. B., O'brien, W. & Barton, T. 2022. Common human errors in design, installation, and operation of VAV AHU control systems-A review and a practitioner interview. Building and Environment, 221.
Wang, H. T., Feng, D. G. & Liu, K. 2021. Fault detection and diagnosis for multiple faults of VAV terminals using self-adaptive model and layered random forest. Building and Environment, 193.
Wei, D., Feng, H. D., Han, Q. & Jia, K. 2022. Fault detection and diagnosis for variable-air-volume systems using combined residual, qualitative and quantitative techniques. Energy and Buildings, 254.
Yao, W. L., Li, D. H. & Gao, L. 2022. Fault detection and diagnosis using tree-based ensemble learning methods and multivariate control charts for centrifugal chillers. Journal of Building Engineering, 51.
Zhu, X., Chen, K., Anduv, B., Jin, X. Q. & Du, Z. M. 2021. Transfer learning based methodology for migration and application of fault detection and diagnosis between building chillers for improving energy efficiency. Building and Environment, 200.
How to cite this article
Bai, X., Liang, C., Tang, Q., Mao, Y. and Huang, J. (2023). 'Enhancing energy efficiency in hospital buildings: A comprehensive diagnosis strategy for chiller plant fault detection'. SET Proceedings, 20(1), pp. 412-422. https://doi.org/10.65582/set.2023.046