Poor glazing insulation and natural window ventilation represent an average of 15% and 35% primary energy consumption in most of residential and commercial buildings, which is crucial in energy conservation for net zero energy target in 2050. Besides, occupants spend about 90% of their time on indoor activities, where sick building syndromes (e.g., pruritus, dry cough, ocular pruritus, and headache) are attributed to poor indoor air quality, as well as diseases like extrinsic allergic alveolitis and asthma. This paper proposed a smart all-in-one window by integrating the PV vacuum glazing, heat pipe-based window heat recovery ventilation unit and battery storage for space heating, cooling, insulation, ventilation, heat recovery and renewable electricity generation and storage. The PV vacuum glazing generate the electricity and stored in the battery to supply the window heat recovery ventilation when required. And the glazing insulation achieves U-value of 0.5 W/m²K with glazing solar to electricity conversion efficiency of 5.28% with light transparency of 50%. In addition, the window heat recovery unit using the heat pipe as high thermal conducting method with heat recovery efficiency between 74%-94% with variation of ventilation rate between 10-60m³/h. A 1940s’ British masonry house is selected as a case study to evaluate the comprehensive energy, comfort, and economic performance by utilizing the all-in-one smart window. Results indicate that the room total energy is reduced by 15.3% annually with quick payback periods of 7 years. Moreover, grid electricity consumption for lighting and ventilation reduced by 84.6%. It is also noted that the average indoor CO2 content during sleep time is reduced from 1740PPM to 950PPM as 100% warm and fresh air inlet from the window heat recovery unit, which indicates a significant improvement of indoor thermal comfort. Thus, the proposed smart all-in-one window could play a significant role in the future lo-carbon building design in both retrofit and newly constructed building.
Babota, F. (2014). "Mechanical Ventilation Systems With Heat Recovery For Refurbishment Projects And New Buildings." Bulletin of the Polytechnic Institute of Jassy, CONSTRUCTIONS. ARCHITECTURE Section 60: 39-50.
Barreto, G., K. Qu, Y. Wang, M. Iten and S. Riffat (2022). "An innovative window heat recovery (WHR) system with heat pipe technology: Analytical, CFD, experimental analysis and building retrofit performance." Energy Reports 8: 3289-3305.
Belmans, B., D. Aerts, S. Verbeke, A. Audenaert and F. Descamps (2019). "Set-up and evaluation of a virtual test bed for simulating and comparing single- and mixed-mode ventilation strategies." Building and Environment 151.
Calautit, J. K., D. O’Connor, P. W. Tien, S. Wei, C. A. J. Pantua and B. Hughes (2020). "Development of a natural ventilation windcatcher with passive heat recovery wheel for mild-cold climates: CFD and experimental analysis." Renewable Energy 160: 465-482.
Dowson, M., A. Poole, D. Harrison and G. Susman (2012). "Domestic UK retrofit challenge: Barriers, incentives and current performance leading into the Green Deal." Energy Policy 50: 294-305.
Ekins, P. and E. Lees (2008). "The impact of EU policies on energy use in and the evolution of the UK built environment." Energy Policy 36(12): 4580-4583.
Jarimi, H., K. Qu, S. Zhang, Q. Lv, J. Liao, B. Chen, H. Lv, C. Cheng, J. Li, Y. Su, S.-j. and S. Riffat (2020). "Performance Analysis of a Hybrid Thin Film Photovoltaic (PV) Vacuum Glazing." Future Cities and Environment 6.
Krieger, J. and D. Higgins (2002). "Housing and Health: Time Again for Public Health Action." American journal of public health 92: 758-768.
Mardiana-Idayu, A. and S. B. Riffat (2012). "Review on heat recovery technologies for building applications." Renewable and Sustainable Energy Reviews 16(2): 1241-1255.
Paone, A. and B. Jean-Philippe (2018). "The Impact of Building Occupant Behavior on Energy Efficiency and Methods to Influence It: A Review of the State of the Art." Energies 11: 953.
PolySolar. "PRODUCT SPECIFICATIONS AND DATASHEETS." Retrieved 28th May, 2022, from https://www.polysolar.co.uk/technology/_domestic-info-specifications.
Rasheed, E., R. H. B, B. Money, J. Mbachu and T. Egbelakin (2017). "Why Are Naturally Ventilated Office Spaces Not Popular in New Zealand?" Sustainability 2017.
Shen, S., W. Cai, X. Wang, Q. Wu and H. Yon (2017). "Investigation of liquid desiccant regenerator with fixed-plate heat recovery system." Energy 137: 172-182.
Simonson, C. (2005). "Energy consumption and ventilation performance of a naturally ventilated ecological house in a cold climate." Energy and Buildings 37: 23-35.
Vali, A., C. J. Simonson, R. W. Besant and G. Mahmood (2009). "Numerical model and effectiveness correlations for a run-around heat recovery system with combined counter and cross flow exchangers." International Journal of Heat and Mass Transfer 52(25): 5827-5840.
Yau, Y. H. and M. Ahmadzadehtalatapeh (2010). "A review on the application of horizontal heat pipe heat exchangers in air conditioning systems in the tropics." Applied Thermal Engineering 30(2): 77-84.
Young, M., B. D. Less, S. M. Dutton, I. S. Walker, M. H. Sherman and J. D. Clark (2020). "Assessment of peak power demand reduction available via modulation of building ventilation systems." Energy and Buildings 214: 109867.
Zender - Świercz, E. (2021). "A Review of Heat Recovery in Ventilation." Energies 14: 1759.
How to cite this article
Qu, K., Wang, Y. and Riffat, S. (2023). 'Performance of the smart all-in-one window with integration of PV vacuum glazing and window frame heat recovery ventilation system'. SET Proceedings, 20(2), pp. 46-56. https://doi.org/10.65582/set.2023.056