Covid-19 and Brexit accelerated the move to an e-commerce economy in the UK. The issue with this is that for every 1 billion pounds spent online, a further 750,000 square feet of warehouse space is required. Just one average-sized warehouse today consumes as much electricity as 400 British households. The energy consumption of the fast-growing warehouse sector poses a mammoth problem, made worse by outdated building regulation, and a lack of understanding of how these buildings perform. It is widely understood amongst building engineers that the primary solution to reducing energy consumption of any building is to incorporate a level of natural ventilation, meaning little to no use of fans and therefore eradicating the associated electricity consumption. Warehouses represent a neglected building type in ventilation design guidance and regulation as using benchmarks for required fresh air person does not serve such a space with a large volume compared to number of occupants. This paper looks at one of the primary driving forces of ventilation, wind, and how a typical storage and distribution warehouse performs under different wind speeds and wind angles. Using lab-scale wind tunnel data to verify a computational fluid dynamics model of a case study warehouse, the results close the gap in understanding of whether cross-ventilation is a viable strategy for large, shed buildings. The results indicate that positioning inlet and outlet ventilation openings on opposite facades across the length of a standard-shaped warehouse can provide a consistent level of ventilation not just for fresh air purposes, but also to tackle the key issues of stratification in tall spaces and pressure-balancing with the frequently open large rolling bay doors. The future of the built environment is ever-changing as society evolves, and the research in this paper can help inform new and improved building regulation for these unique, large spaces to highlight that ventilation design guidance in national and international standards is incomplete.
Bartolini, M.; Bottani, E.; Grosse, E.H. Green warehousing: Systematic literature review and bibliometric analysis. J. Clean. Prod. 2019, 226, 242–258
Brinks, P., Kornadt, O., and Oly, R., 2016. Development of concepts for cost-optimal nearly zero-energy buildings for the industrial steel building sector. Applied Energy, 173, pp. 343-354.
Chen, H., Zhuang, X., Rashidi, S., Yan, W., 2023. Temperature control in warehouse with internal and external heat rejections. International Journal of Thermal Sciences, 194, 108600.
CIBSE, “CIBSE Guide B - Heating, Ventilating, Air-Conditioning and Refrigeration,” CIBSE, 2020.
Cook, P., and Sproul, A., 2011. Towards low-energy retail warehouse building. Architectural Science Review, 54:3, 206-214
Dhooma, J., and Baker, P., 2012. An Exploratory Framework for Energy Conservation in Existing Warehouses. International journal of logistics, 15.1, pp.37–51.
Eini, R., Linkous, L., Zohrabi, N., Abdelwahed, S., 2021. Smart building management system: Performance specifications and design requirements. Journal of Building Engineering, 39, 102222.
Freis, J.; Vohlidka, P.; Günthner, W. A. Low-Carbon Warehousing: Examining Impacts of Building and Intra-Logistics Design Options on Energy Demand and the CO2 Emissions of Logistics Centers. Sustainability 2016, 8, 448.
IBM, “Building energy analytics for cooling and heating is helping to fight climate change,” 2020. [Online]. Available: https://www.ibm.com/blogs/ibm-anz/building-energy-analytics-for-cooling-and-heating-is-helping-to-fight-climate-change/. [Accessed July 2021].
Lewczuk, K., Klodawski, M. and Gepner, P., 2021. Energy Consumption in a Distributional Warehouse: A Practical Case Study for Different Warehouse Technologies. Energies, 14(9), pp. 2709.
Mohammad, N., and Rahman, A., 2019. Transactive control of industrial heating-ventilation-air-conditioning units in cold-storage warehouses for demand response. Sustainable Energy, Grids and Networks, 18, 100201.
OVO Energy, “Average electricity usage in the UK: how many kWh does your home use?,” 18 March 2021. [Online]. Available: https://www.ovoenergy.com/guides/energy-guides/how-much-electricity-does-a-home-use. [Accessed July 2022].
Park, S., Cho, S., and Ahn. J., 2018. Improving the Quality of Building Spaces That Are Planned Mainly on Loads Rather Than Residents: Human Comfort and Energy Savings for Warehouses. Energy and buildings, 178, pp.38–48.
Porras-Amores, C., Mazarrón, F., Cañas, I., 2014. Study of the Vertical Distribution of Air Temperature in Warehouses. Energies 7, 1193–1206.
Shaer, I., and Shami, A., 2023. Data-driven methods for the reduction of energy consumption in warehouses: Use-case driver analysis. Internet of Things, 23, 100882.
United Kingdom Warehouse Association (UKWA), “New report reveals major growth and seismic changes in UK warehousing sector,” UKWA, 2021. [Online]. Available: https://www.ukwa.org.uk/market-intel/new-report-reveals-major-growth-and-seismic-changes-in-uk-warehousing-sector/. [Accessed July 2022].
United Kingdom Warehouse Association (UKWA), “https://www.ukwa.org.uk/wp-content/uploads/2021/05/Savills-UKWA-A4-8pp-Report-Interactive3.pdf,%E2%80%9D UKWA, 2021.
UK GOV, “Ventilation: Approved Document F”, UK GOV, 2010
UK GOV, “Ventilation: Approved Document F”, UK GOV, 2021
Wang, L.L; Li, W. A study of thermal destratification for large warehouse energy savings. Energy Build. 2017, 153, 126-135.
Zajac, P.; Kwasniowski, S. Zero energy buildings in the logistics warehouse systems. E3S Web Conf. ASEE17 2017, 22, 00198.
How to cite this article
Pelletier, K., Wood, C. and Calautit, J. (2023). 'Storage and distribution warehouses: a neglected building type in natural ventilation design'. SET Proceedings, 20(2), pp. 227-235. https://doi.org/10.65582/set.2023.076