A site museum is a special public building for preserving and exhibiting immovable historical sites. It typically features a large-space layout and requires high energy consumption for HVAC system. Its interior space can be categorized into three sections: visitor corridor, relics preservation area and a non-occupied space. Of these, the visitors corridor accounts for only about 20% of the total indoor space. Conventional air conditioning (AC) systems typically heat the entire exhibition hall, resulting in excessive energy consumption and inadequate thermal comfort for visitors. In this research, by using an air curtain to separate the visitor corridor from the large space exhibition hall, an underfloor heating system is proposed to provide local heating for the visitor corridor. An experimental exhibition hall and local heating system for the visitor corridor were constructed based on the spatial characteristics of Emperor Qin's Mausoleum Site Museum. A series of tests were conducted to evaluate the performance of the local heating system and consequently the system parameters were optimised. The results showed that the environmental parameters within the visitor corridor were regulated to temperatures of 18-22°C, relative humidity>30%, air velocity <0.3m/s, and a temperature difference of <2°C within the human-occupied space, providing a stable environment that meets the thermal comfort needs of visitors for short-term stays, and significantly reducing energy consumption compared to traditional HVAC systems and advancing energy conservation and emission reduction efforts. The proposed system provides an efficient and energy-saving strategy for local environmental control of visitor areas in large on-site exhibition halls.
Keywords. Local Heating; Underfloor Heating System; Air Curtain; Energy-Efficient Buildings; Indoor Thermal Comfort
References
Dang Y. X., Luo X. L., Chang B., Huang X. Y., Feng Z. B., & Gu Z. L., 2022, Local attachment ventilation system for the unearthed relic preservation area within site museum, Sustainable Cities and Society, 77, 103537.
Dong Z. W., Zhang L. T., Yang Y. W., Li Q. F., Huang H., 2021, Numerical study on coupled operation of stratified air distribution system and natural ventilation under multi-variable factors in large space buildings, Energies, 14 (23), 8130-8130.
Hu T. F., Jia W. T., Cao J. J., Huang R. J., Li H., Liu S. X., Ma T., & Zhu Y. Q., 2015, Indoor air quality at five site museums of Yangtze River civilization, Atmospheric Environment, 123, 449-454.
Huang X. Y., Luo X. L., Shen C., Chang B., & Gu Z. L., 2023, Local heating of a visitor corridor within a large site museum exhibition hall via an integrated jet ventilation and air curtain system, Journal of Building Engineering, 69, 106206.
Huang Y. Y., Zhang L., & Han X. H., 2011, Application on the Stratified Air Conditioning System with Low Velocity in the Main Hall of the Temple, Advanced Materials Research, 1329 (280-280), 141-146.
Li H. X., Xiao W., Geng G., Li B. N., & Wang W., 2012, Field Test for Heat and Humidity Environment and Analysis of Air-Conditioning System Consumption, Advanced Materials Research, 610-613, 2875-2878.
Lin W. Y., Liu X. H., Zhang T., & Zhou Z. Q., 2022, Investigation of displacement and jet ventilation systems applied in an ice rink. Journal of Building Engineering, 50, 104179.
Liu Z. J., Wu M. N., Cao H. W., Liu H. Y., Wang H. N., Lv J. B., Rong R., & He J. Z., 2022, Impact of the visitor walking speed and glass barriers on airflow and Bioaerosol particles distribution in the typical open tomb, Building and Environment, 225, 109649.
Luo X. L., Gu Z. L., Yu C. W., Li K., & Xiao B., 2016, Preservation of in situ artefacts by local heating in earthen pit in archaeology museum in cold winter, Building and Environment, 99, 29-43.
Luo X. L., Huang X. Y., Feng Z. B., Li J., & Gu Z. L., 2021, Influence of air inlet/outlet arrangement of displacement ventilation on local environment control for unearthed relics within site museum, Energy & Buildings. 246, 111116.
Luo X. L., Lei S. L., Tian W., & Gu Z. L., 2020, Evaluation of air curtain system orientated to local environmental control of archaeological museum: A case study for the stone armor pit of Emperor Qin’s Mausoleum Museum, Sustainable Cities and Society, 57, 102121.
Ye X., Kang Y. M.,Yang F., & Zhong K. 2019, Comparison study of contaminant distribution and indoor air quality in large-height spaces between impinging jet and mixing ventilation systems in heating mode. Building and Environment, 160, 106159.
Yu L. X., Liu F., Beji T., Weng M.C., & Merci B., 2018, Experimental study of the effectiveness of air curtains of variable width and injection angle to block fire-induced smoke in a tunnel configuration. International Journal of Thermal Sciences, 134, 12-36.
Zhao K., Weng J. T. & Ge J., 2020, On-site measured indoor thermal environment in large spaces of airports during winter, Building and Environment, 167, 106463.
How to cite this article
Li, J., Li, H., Sun, R., Gu, Z. and Luo, X. (2024). 'Localized heating for visitor corridor within site museum using radiant floor heating and air curtain system'. SET Proceedings, 21(2), pp. 11-20. https://doi.org/10.65582/set.2024.056