With the development of society and the growth of population, the demand for energy continues to increase. Utilizing subway source heat pump technology to extract shallow geothermal energy for cooling or heating for users, making shield tunnel subways become energy tunnels, is one of the most effective technologies to solve the problem of energy demand. However, the thermal impact of heat exchanger operation on tunnel structures still needs further research. Based on COMSOL Multiphysics software, this paper analyzes the heat exchange performance of the Capillary Heat exchanger (CHE) in energy tunnels and the structural mechanical response of shield tunnel segments during CHE operation under typical heating season and cooling season conditions. The results indicate that the performance of precast CHE in energy tunnels is excellent. A single-ring energy tunnel can provide cooling and heating capacities of 601.62W and 466.28W, respectively, during the cooling and heating seasons, with heat transfer efficiency of 63.46W/m² and 49.19W/m² respectively. The operation of the CHE during the cooling season leads to elongation of the tunnel segments, while during the heating season, compression of the tunnel segments occurs. The maximum tensile stress and maximum compressive stress generated in heating season are 0.60 MPa and 0.73 MPa respectively, while in cooling season they are 0.56 MPa and 0.87 MPa respectively. The compressive stresses generated during the cooling and heating seasons due to CHE operation are far below the compressive limit of C50 concrete, with tensile stresses representing 33% and 23% of the axial tensile strength, respectively. The calculation results indicate that under the design conditions of the heat pump unit, when the heat exchange between the CHE and the tunnel reaches steady state, the impact of CHE heat exchange on the structural integrity of the shield tunnel is relatively minor.
Keywords. Heat Pump; Capillary Heat Exchanger; Energy Tunnel; Thermal-Structural Coupling
References
National Bureau of Statistics, (2022) ‘China Statistical Yearbook’. Beijing shu tong dian zi chu ban she. (In Chinese)
Jiang, Y. Hu, S. and Zhang Y., et al. (2022) ‘China building energy efficiency annual development research report’. (In Chinese)
Geothermal energy information. (2023) Qian, Q.H: establish and improve the mechanism of shallow geothermal energy application. Available at: https://mp.weixin.qq.com/s/r9odhwxjE340mrIfddnxjA (Accessed: 15 August 2023).
Brandl, H. (2006). ‘Energy foundations and other thermo-active ground structures’. Géotechnique, 56(2), pp.81-122.
Adam, D., and Markiewicz, R. (2009) ‘Energy from earth-coupled structures, foundations, tunnels and sewers’. Géotechnique, 59(3), pp.229-236.
Wang, H.Y. Hu, S.T. and Chang Z. et al. (2014) The invention relates to a capillary soil source heat pump system applied to a subway tunnel. (2014-03-05). CN103615841A.
Xia, C.C. Yang, Y. Zhang, G.Z. and Zou, Y.C. (2014) ‘The internal source heat pump heat exchange tube and tunnel structure interact’. Journal of Tongji University (Natural Science Edition), (1), pp.51-57. (In Chinese)
Yang, Y. Xia, C.C. and Zhu, J.L. (2014) ‘Study on temperature stress induced by heat exchange tube of tunnel ground source heat pump’. Journal of Central South University: Natural Science Edition, 45(11), pp.3970-3976. (In Chinese)
Zhu, Z.N. (2020) ‘Analysis of heat transfer, stress and construction problems of energy shield tunnel’. (Master's thesis, Tsinghua University).
Di Donna, A. and Barla, M. (2016) ‘The role of ground conditions on energy tunnels’ heat exchange’. Environmental geotechnics, 3(4), pp.214-224.
Ministry of Construction of the People's Republic of China. (2013) ‘GB 50157-2013 Code for design of metro’. Beijing: China Building Industry Press.
Ministry of Construction of the People's Republic of China. (2005) ‘GB 50366-2005 Technical code for ground-source heat pump system’. Beijing: China Building Industry Press.
Zhu, H.H. and Tao, L.B. (1998) A beam-spring system model for stress analysis of shield tunnel lining structures. Journal of Rock and Soil Mechanics, 19(2), pp.26-32. (In Chinese)
Zhang, Y. Zhang, Q. Bi, H.Q. and Wang, J.Y. (2020) ‘Experimental study on wind speed and its variation in metro piston duct’. Refrigeration and air conditioning (Sichuan), 34(04), pp. 463-467. (In Chinese)
Ji, Y.M, Wu, W.Z. and Hu, S.T. (2023) ‘Long-term performance of a front-end capillary heat exchanger for a metro source heat pump system’. Applied Energy, 335, p.120772.
Gao, H. (2015) Research on Heat Transfer Characteristics of Capillary Heat exchangers in Subway Tunnel (Doctoral dissertation, Qingdao: Qingdao University of Technology).
Lu Y.Q. (2008) ‘Practical heating and air conditioning design manual. second ed’. Beijing: China Construction Industry Press. (In Chinese).
Ji, Y.M. Wu, W.Z. Qi, H.Y. Wang, W.Q and Hu, S.T. (2022) ‘Heat transfer performance analysis of front-end capillary heat exchanger of a subway source heat pump system’. Energy, 246, p.123424.
Insana, A. (2020). Thermal and structural performance energy tunnels. Politecnico di Torino.
How to cite this article
Shen, S., Zhang, H., Wang, X., Ji, Y. and Hu, S. (2024). 'Thermal-structural coupling characteristic analysis of shield energy tunnel under design condition'. SET Proceedings, 21(2), pp. 212-229. https://doi.org/10.65582/set.2024.079