This paper outlines the analysis method of plant operation states (POSs) under low power and shutdown (LPSD) operations, with a focus on the key steps. Using this analysis method, a set of LPSD POSs, the statistical analysis method and results of each POS duration, and a sensitivity analysis have been determined in this paper. According to the sensitivity, it is reasonable to calculate each POS duration based on existing outage records and in conjunction with the medium and long-term outage plans. This paper could provide a reference for the probabilistic safety assessment (PSA) on EPR.
Keywords. Plant Operational States; Low Power and Shutdown; PSA
References
China Nuclear Energy Association, 2014. Level 1 PSA Peer Review guideline for Internal Events at-low Power and Shutdown, Beijing: China Atomic Energy Press.
National Energy Administration, 2021. level 1 Probability Safety Assessment for nuclear power plant applications- Part 2: Internal events at low power and shutdown, NB/T 20073.2-2021,Beijing: China Atomic Energy Press.
How to cite this article
Wang, W. and Wang, Y. (2024). 'Plant operation states analysis for low power and shutdown PSA on EPR'. SET Proceedings, 21(3), pp. 342-346. https://doi.org/10.65582/set.2024.140