In indoor environments, the thermal environment, particularly the air temperature, is crucial for occupant comfort and energy consumption. In contrast, advanced computer simulations have emerged to accurately predict temperature variations and energy use in indoor spaces in recent decades. Simple hand calculation methods are still needed to provide initial estimates for architecture or facility managers. However, more reliable methods must be used to estimate the relationship between temperature and energy consumption in daily-used small spaces, such as bathrooms. Despite lower overall energy consumption compared to larger spaces, bathrooms often have higher energy consumption per unit area, indicating significant potential for energy savings. This study aimed to correlate temperature changes and energy consumption using data collected in a laboratory chamber. The chamber dimensions and layout were designed to represent a typical bathroom, facilitating a toilet, showerhead, basin, ceiling light, portable heater, and exhaust fan. Eight scenarios with different combinations of lighting (on/off), heater (on/off), and exhaust fan (on/off) settings were tested, with each scenario repeated twice for a total of 16 sample cases. Building on the power-law relationships between temperature rise, energy release rate, and wall heat gain established by previous researchers, this study updated the coefficients of the original equations to fit better the experimental data collected. The correlation model developed in this study can be used to predict bathroom temperatures based on environmental settings or to estimate energy consumption based on desired temperature. The model provides a simple yet effective tool for building designers and facility managers to assess bathrooms' thermal performance and energy implications during the design phase or for retrofit applications. The results of this study could directly inform more sustainable design strategies for bathrooms. However, it should be noted that the current study is the beginning that only considered two heat sources (i.e., heater and lighting). Future research should investigate the impact of additional factors, such as hot water flow, on bathroom temperature changes and energy use during showering to identify a thermal comfort and energy-saving bathroom environment.
Keywords. Energy Consumption; Thermal Comfort; Temperature Changes; Bathroom; Prediction Model
References
Cheng, F., Zhang, S., Gao, S., Tian, X., Liao, C., & Cheng, Y. (2020). Experimental investigation of airflow pattern and turbulence characteristics of stratum ventilation in heating mode. Building and Environment, 186. https://doi.org/10.1016/j.buildenv.2020.107339
Foote, K. L., Pagni, P. J., & Alvares, N. J. (1986). Temperature Correlations for Forced-Ventilated Compartment Fires. Fire Safety Science, 1, 139–148. https://doi.org/doi:10.3801/IAFSS.FSS.1-139
Hong Kong Electrical & Mechanical Services Department. (2022). Hong Kong Energy End-use Data 2022.
Laskari, M., de Masi, R. F., Karatasou, S., Santamouris, M., & Assimakopoulos, M. N. (2022). On the impact of user behaviour on heating energy consumption and indoor temperature in residential buildings. Energy and Buildings, 255. https://doi.org/10.1016/j.enbuild.2021.111657
McCaffrey, B. J., Quintiere, J. G., & Harkleroad, M. F. (1981). Estimating room temperatures and the likelihood of flashover using fire test data correlations. Fire Technology, 17(2), 98–119. https://doi.org/10.1007/BF02479583
Olu-Ajayi, R., Alaka, H., Sulaimon, I., Sunmola, F., & Ajayi, S. (2022). Building energy consumption prediction for residential buildings using deep learning and other machine learning techniques. Journal of Building Engineering, 45. https://doi.org/10.1016/j.jobe.2021.103406
Wong, L.-T., Mui, K.-W ., & Guan, Y. (2010). Shower water heat recovery in high-rise residential buildings of Hong Kong. Applied Energy, 87(2), 703–709. https://doi.org/10.1016/j.apenergy.2009.08.008
Zhang, D., Mui, K.-W., & Wong, L.-T. (2023). Establishing the Relationship between Occupants’ Thermal Behavior and Energy Consumption during Showering. Buildings, 13(5), 1300. https://doi.org/10.3390/buildings13051300
How to cite this article
Zhang, D., Mui, K. and Wong, L. (2024). 'Correlation between air temperature and energy compensation rate in bathrooms: an experimental study'. SET Proceedings, 21(4), pp. 273-280. https://doi.org/10.65582/set.2024.188