This paper focuses on the classification of non-isolated small break loss-of-coolant accidents (LOCA) for the EPR nuclear power unit at Taishan Nuclear Power Plant under shutdown conditions. Through the calculation of primary circuit pipe break frequencies and the use of event tree analysis to determine the frequency of stuck-open safety valve events in the pressurizer, the study determines the frequency of non-isolated small breaks under shutdown conditions. Probabilistic safety assessment methods are employed to determine the risk importance of non-isolated small breaks under shutdown conditions. Based on the event frequency and risk importance analysis results, non-isolated small LOCA accidents under operational states C, D, and E are categorized as design extension accidents. This analysis provides technical support for the modification of the Final Safety Analysis Report (FSAR) and operating technical specifications for the EPR nuclear power unit, thereby achieving the goal of simplifying requirements in the operating technical specifications, shortening major maintenance durations, and enhancing the capacity factor of the unit.
Keywords. EPR; FSAR; Initiating Event; LOCA
References
AREVA, 2007.01, CATEGORIZATION OF INITIATING EVENTS ACCORDING TO EXPECTED FREQUENCIES OF OCCURRENCE , REV. A., 13.
EPRI, NSAC176L, 1992.08, Safety Assessment of PWR Risk During Shutdown Operations , C- 6
Fangchenggang Nuclear Power Plant, Fangchenggang Nuclear Power Plant Unit 3, 4 Final Safety Analysis Report Volume 15 15.0,C version: 4-7
National Nuclear Safety Administration,2016.10,HAF102-2016 safety regulations for nuclear power plant design .16-17
Paris P C,Erdogan F.1963, A critical analysis of crack propagation laws.Journal of Basic Engineering ASME(Series.D 528-534
Sanmen Nuclear Power Co., Ltd.,2018.10, Final safety analysis report of Unit 1 & 2 of phase I project of Sanmen nuclear power 15 volume 15.0,3 edition, 2-4
Taishan nuclear power plant,2020.9,Final safety analysis report of units 1 and 2 of Taishan nuclear power plant, volume 15 15.0.0. Version C,4
U.S NRC, June, 2007, NUREG/CR-6932 Base line Risk Index for Initiating Events
U.S NRC, 1999.2, NUREG/CR-5750 Rates of Initiating Events at U. S. Nuclear Power Plants: 1987-1995 ,11-12
Xue Fei, Han Weiwei, Meng Xinming, et al, 2014, Experimental study on fatigue crack growth characteristics of main pipe of domestic PWR nuclear power plant. Chinese Journal of electrical engineering, 1310-1317
How to cite this article
Cao, G., Yuan, M. and Wang, W. (2024). 'Study on the classification and optimization of non isolated small LOCA accidents of EPR nuclear power units under shutdown conditions'. SET Proceedings, 21(4), pp. 482-489. https://doi.org/10.65582/set.2024.210