Skip to content
Caravel Press

Conference paper

Decarbonization of Residential Buildings Using Low-Charge R290 Heat Pumps: Experimental and Numerical Approach

, , , , , , ,

1Korea Institute of Energy Research, Daejeon, Republic of Korea

Open accessCC BY 4.0Published 23 Nov 2026https://doi.org/10.65582/set.2026.010
Download PDF13 pages · 2.1 MB

Abstract

Decarbonization of residential buildings is a critical strategy for mitigating greenhouse gas emissions, with heat pump systems emerging as a viable alternative to conventional fossil-fuel-based heating technologies. Among natural refrigerants, R290 (propane) is particularly promising due to its negligible global warming potential and favourable thermophysical properties. However, its flammability imposes strict constraints on allowable refrigerant charge, necessitating the development of low-charge system designs for safe residential applications. This study presents a combined experimental and numerical investigation of refrigerant charge reduction in a water-to-water R290 heat pump system for residential use. The effects of heat exchanger geometry and compressor modulation on system performance are systematically analysed. A numerical model is developed to simulate system performance and is validated against experimental measurements. The specific charge (g/kW) is adopted as a key performance metric to quantify charge efficiency relative to heating capacity. The results demonstrate that optimized system design and operating conditions can significantly reduce refrigerant charge while maintaining stable thermal performance. A minimum specific charge of 24.12 g/kW is achieved using the asymmetric heat exchanger configuration in combination with variable-speed compressor operation, without compromising the system efficiency. Furthermore, the findings suggest that low-charge R290 heat pump systems have strong potential for integration into advanced thermal energy storage technologies, such as Carnot Battery systems, where efficient heat transfer and minimized refrigerant inventory are critical for system scalability and safety. This highlights the broader applicability of the proposed approach beyond residential heating.

Keywords. R290 heat pump; Specific charge (g/kW); Charge minimization; Decarbonization

© 2026 The Author(s). Published by Caravel Press.

Anyone may read, download, copy, distribute and build on this article, in any medium or format, provided the authors and the original article are credited. Read the CC BY 4.0 licence

← SET Proceedings