Conference paper
Experimental Investigation of the Effects of MXene Concentration and Optical Filter Layer Thickness on PV/T System Performance
, ,
1Shandong Jianzhu University, 1000 Fengming Road, Jinan, 250101, China
* Correspondence: Ziyan Sun, [email protected]
History
Received
15 Apr 2026
Revised
20 May 2026
Accepted
1 Jun 2026
Published
23 Nov 2026
Received to published in 222 days·Pages 82-94
Abstract
Keywords. Solar PV/T system; Optical filtration layer; Nanofluids; Thermal and electrical energy efficiency; Photovoltaic cell
1. Introduction
Solar energy is an abundant renewable resource with considerable potential to meet electricity and heating demands. Photovoltaic/thermal (PV/T) systems recover heat from PV cells while generating electricity, thereby improving the utilization of incident solar energy (Herrando et al. 2023). Their performance depends on both the solar spectrum reaching the cells and heat removal from the absorber. Optical filtration offers an additional means of controlling this energy distribution. A liquid filter can absorb part of the incident radiation before it reaches the PV surface, but attenuation within the useful PV response band can also reduce electrical generation (Cui et al. 2026; Jiao et al. 2024).
Liquid filters have been investigated using emulsions (Lee et al. 2023), water (Yadav et al. 2024), silver nanofluids (Wang et al. 2025), CNT/Ag mixtures (Xia et al. 2023), and magnetic nanofluids (Xing et al. 2024). MXene has attracted interest because of its optical absorption characteristics and light-to-heat conversion capability (Zeng et al. 2024). Recent research has also demonstrated the potential of MXene-based nanofluids to balance optical absorption, dispersion stability, and photothermal performance (Anwer et al. 2025). Studies using oil-based MXene nanofluids (Rubbi et al. 2020), MXene/water nanofluids (Wang et al. 2021), and MXene/methanol nanofluids (Dashtbozorg et al. 2025) provide evidence for their application in solar thermal conversion and PV/T thermal management. More directly, Cui et al. (2025) experimentally compared liquid optical filtration PV/T modules using different working fluids, in a subsequent study (Cui et al. 2026), they employed both numerical simulations and experimental validation to investigate the effects of the filtering layer thickness, MXene concentration, and operating conditions (Cui et al. 2026).
Despite the promising optical and thermal properties of MXene-based nanofluids, their application as spectral filtering media in PV/T systems remains insufficiently investigated. In particular, the relationship between the optical losses introduced by spectral regulation and the thermal benefits obtained from nanofluid cooling has not been fully clarified. Therefore, the authors developed a hybrid PV/T system incorporating MXene/water nanofluids as both optical filter layers (OFLs) and heat transfer fluids (HTFs). Uncovered monocrystalline silicon PV cells were employed to eliminate the influence of the conventional glass cover and accurately evaluate the intrinsic effects of the optical filter layers. The authors experimentally investigated the effects of MXene concentration (0.0005 wt% and 0.001 wt%) and optical filter layer thickness (1, 3, and 5 cm) on the electrical and thermal performance of the PV/T system under indoor conditions.
2. Materials and methods
2.1. Physical model of PV/T system
Figure 1 presents the structure of the PV/T module with OFL. The module consists of a liquid-based OFL fabricated from quartz glass, which exhibits a broadband transmittance of approximately 92% over the wavelength range of 350-2500 nm (Cai et al. 2025), a monocrystalline silicon PV cell, a serpentine copper tube bonded to the rear of the absorber and a layer of insulation at the bottom.
The surface temperature of the module is influenced by direct solar radiation and heat exchange with the atmospheric environment. When solar radiation reaches the OFL surface, a portion of the ultraviolet portion is absorbed, and some radiation is absorbed or scattered within the OFL, while the remaining radiation passes through the OFL and reaches the PV surface. The nanofluids within the OFL exhibit unique optical properties as spectral filtering fluids, which depend on the optical characteristics of both the base fluid and the nanoparticles. The PV cell generates electricity under solar irradiation while its temperature rises. Heat is removed from the cell by the heat transfer fluid circulating through the copper tube, while the bottom insulation layer reduces heat loss to the surroundings.
2.2. MXene nanofluid preparation and physical properties
Based on existing research, a two-step method is used to prepare the stable MXene nanofluids (Sanjeevi and Loganathan 2020). Figure 2 illustrates the preparation process of MXene/water nanofluid: (i) MXene powder and trisodium citrate dihydrate (TCD) surfactant as 1:3 ratio is added to de-ionized water (DI-water); (ii) the mixture is stirred on a magnetic stirrer at 600 rpm for 30 minutes to obtain a uniform liquid; (iii) the mixture liquid is placed under an ultrasonic probe (FS-1200N) with 4/6 s on/off pulsing for 2 hours to obtain the MXene/water solution.
SEM and EDS were used to examine the morphology and elemental distribution of samples from the same batch. SEM imaging was performed at 5 kV and 25 ± 2 °C. The SEM result reveals a typical accordion-like layered structure of MXene nanosheets, confirming the successful exfoliation of the MAX precursor into two-dimensional layers. EDS confirms the presence of Ti, C and Cl elements, verifying the Ti-C framework of Ti₃C₂Tx MXene, with Cl originating from surface terminations introduced during etching.
Spectral transmittance was measured with a T700S UV-Vis spectrophotometer using a 10 mm quartz cuvette. The transmittance of MXene nanofluids at two different concentrations as a function of wavelength is shown in Figure 3. The average transmittance of the 0.0005 wt% and 0.001 wt% MXene nanofluids was approximately 89.22% and 78.91%, respectively, corresponding to a relative decrease of 11.56%. The higher transmittance of the 0.0005 wt% MXene nanofluid allows a greater portion of incident radiation to reach the underlying PV cell, whereas the stronger optical attenuation of the 0.001 wt% MXene nanofluid increases the interception of incident radiation within the filtering layer.
Thermal conductivity was measured with a TEMPOS analyser using a KS-3 sensor after glycerin calibration. Each reported value was averaged from three measurements. Specific heat capacity was measured by a DSC 3500 Sirius instrument using the sapphire comparison method, a 10 °C min⁻¹ heating rate and a nitrogen flow of 20 mL min⁻¹. The test results are shown in Table 1.
Table 1. Thermal physical properties.
| Type | Location | Specific heat capacity (J/kg·K) | Thermal conductivity (W/m·K) |
|---|---|---|---|
| 0.0005 wt% MXene | OFL | 4179 (25 °C) | 0.616 |
| 0.001 wt% MXene | OFL | 4179 (25 °C) | 0.619 |
| 0.1 wt% MXene | HTF | 4178 (25 °C) | 0.630 |
3. Solar PV/T experimental platform
3.1. Indoor experimental test
The indoor layout is shown in Figure 4 and includes (1) solar simulator, (2) PV/T with OFL module, (3) BD100 unidirectional DC transmitter, (4) data taker, (5) peristaltic pump, (6) constant temperature water tank, (7) heat exchanger, and (8) computer. A solar simulator illuminated the module continuously for 60 min in each test. Electrical signals and inlet, outlet and surface temperatures were acquired to compare the response of each filter medium at each thickness. The pump circulated the rear heat-transfer fluid through the module, heat exchanger and temperature-controlled tank. While keeping the fluid concentration on the dorsal side constant, three types of OFL media were compared, and the optimal configuration for OFL concentration and thickness was determined.
In the experiment, the MXene nanofluid serves as heat transfer fluid. The thickness and concentration of OFL are individually varied to test the PV cell temperature and the electro-thermal efficiency of the hybrid PV/T system. The thickness of the OFL above the PV cells is 1, 3, and 5 cm, respectively. The OFL consists of water, 0.0005 wt% MXene, and 0.001 wt% MXene.
4. Power efficiency and uncertainty assessment
To evaluate the impact of the presence of optical filtration layers on the overall PV/T system performance, the measurement data are expressed using two key indicators: electrical efficiency (ηele) and thermal efficiency (ηth). Electrical efficiency refers to the efficiency of converting light energy into electrical energy, which is the ratio of output electrical power to input light power (Yadav et al. 2024).
Where:
- ηele = electrical efficiency (%)
- P = actual output electrical power (W)
- G = solar irradiance (W/m²)
- APV = area of the PV cell (m²)
The thermal energy collected by the PV/T system can be expressed as (Rahmanian and Hamzavi 2020):
Where:
- ηth = thermal efficiency (%)
- cp = specific heat of fluid (J/kg K)
- = mass flow rate of fluid (kg/s)
- Tout = outlet temperature (°C)
- Tin = inlet temperature (°C)
- G = solar irradiance (W/m²)
- APV = area of the PV cell (m²)
Therefore, the overall efficiency of the PV/T module is expressed as (Taylor et al. 2012):
Where:
- ηoverall = overall efficiency (%)
- ηth = thermal efficiency (%)
- ηele = electrical efficiency (%)
Uncertainty analysis of experiments is used to assess the reliability and accuracy of experimental results. For a calculated parameter R = f(x1, x2, …, xi), the combined uncertainty can be expressed as (Srinivasan and Ponnusamy 2025):
Where:
- n = total number of input variables
- xi = the ith input variable
- R = calculated quantity
- Uxi = absolute uncertainty of xi
- UR = combined uncertainty of R
The calculated uncertainties of the electrical and thermal performance parameters remained within acceptable ranges, indicating that indoor experimental measurements were sufficiently reliable for the subsequent performance comparison and analysis.
5. Indoor results and discussions
5.1. Coupling effects of MXene concentration and OFL thickness on temperature variation
Figure 5(a)(b) shows the average PV and OFL surface temperatures over 60 min. At an OFL thickness of 1 cm, the average PV surface temperatures for water, 0.0005 wt% MXene, and 0.001 wt% MXene were 35.0, 36.5, and 36.4 °C, respectively. Both MXene configurations exhibited higher temperatures than water. At 3 cm, the corresponding temperatures decreased to 32.8, 33.8, and 32.3 °C. The 0.001 wt% MXene configuration was therefore 0.5 and 1.5 °C cooler than water and 0.0005 wt% MXene, respectively. At 5 cm, the temperatures decreased further to 32.0, 31.9, and 30.0 °C, increasing these differences to 2.0 and 1.9 °C. Thus, the PV cooling effect of the higher-concentration MXene nanofluid became more pronounced at greater OFL thicknesses.
The OFL surface temperature, however, increased with MXene concentration. As shown in Figure 5(b), the average OFL surface temperatures for water and the two MXene concentrations were 32.5, 34.0, and 34.7 °C at 1 cm, respectively. The corresponding values were 30.8, 32.3, and 33.0 °C at 3 cm and 30.5, 31.7, and 32.5 °C at 5 cm. The 0.001 wt% MXene nanofluid consistently exhibited the highest temperature, exceeding water by 2.2, 2.2, and 2.0 °C at the three thicknesses. Increasing OFL thickness from 1 to 5 cm reduced the average OFL temperatures by 2.0, 2.3, and 2.2 °C for water and the two MXene concentrations, respectively.
These trends are consistent with the combined effects of optical attenuation and fluid thermal mass. Increasing MXene concentration enhanced radiation absorption within the filtering medium, raising the OFL temperature. Increasing OFL thickness extended the optical path length and reduced the radiation reaching the PV surface, making PV cooling more pronounced at the higher concentration. Meanwhile, the greater fluid thermal mass of a thicker OFL limited its temperature rise during the experimental period. Consequently, at greater OFL thicknesses, the higher-concentration MXene nanofluid exhibited a warmer filtering layer and a cooler underlying PV surface.
5.2. Effect of MXene concentration and filter thickness on electrical power output and efficiency
As shown in Figure 6, at each fixed OFL thickness, both electrical power and electrical efficiency decreased with increasing MXene concentration. At 1 cm, water, 0.0005 wt% MXene, and 0.001 wt% MXene produced electrical powers of 1.24, 1.14, and 0.72 W, with efficiencies of 9.4468%, 8.6801%, and 5.4820%, respectively. Relative to water, the two MXene configurations reduced electrical power by 8.06% and 41.94% and electrical efficiency by 8.12% and 41.97%. At 3 cm, the corresponding powers were 1.05, 0.81, and 0.19 W, while efficiencies were 7.9978%, 6.1548%, and 1.4834%. The power reductions relative to water increased to 22.86% and 81.90%, accompanied by efficiency reductions of 23.04% and 81.45%. At 5 cm, electrical powers decreased to 0.87, 0.51, and 0.06 W, with efficiencies of 6.6042%, 3.8723%, and 0.4517%. Compared with water, the two MXene configurations reduced power by 41.38% and 93.10% and efficiency by 41.37% and 93.16%. These results indicate that the electrical penalty associated with increasing concentration became more pronounced at greater OFL thicknesses, consistent with stronger attenuation of radiation reaching the PV cells.
Increasing OFL thickness reduced electrical power and efficiency for all three media. When thickness increased from 1 to 3 cm, electrical power decreased by 15.32% for water, 28.95% for 0.0005 wt% MXene, and 73.61% for 0.001 wt% MXene. The corresponding efficiency reductions were 15.34%, 29.09%, and 72.94%. Increasing thickness further to 5 cm resulted in power reductions of 29.84%, 55.26%, and 91.67% relative to the respective 1 cm configurations, while efficiency decreased by 30.09%, 55.39%, and 91.76%. The greater thickness sensitivity at higher MXene concentration is consistent with increased optical attenuation over a longer optical path. Although thicker filters could reduce PV heating, this cooling benefit did not compensate for the loss of transmitted radiation. Within the tested range, a 1 cm OFL therefore provided the highest electrical power and efficiency for each medium.
5.3. Effect of MXene concentration and filter thickness on thermal power output and efficiency
Figure 7 shows that increasing MXene concentration did not consistently improve thermal performance. At an OFL thickness of 1 cm, water, 0.0005 wt% MXene, and 0.001 wt% MXene produced thermal powers of 3.92, 4.28, and 4.17 W, with thermal efficiencies of 29.902%, 32.694%, and 31.813%, respectively. Relative to water, the two MXene configurations increased thermal power by 9.18% and 6.38% and thermal efficiency by 9.34% and 6.39%. The dilute filter therefore provided the greatest useful heat recovery at this thickness. At 3 cm, the corresponding thermal powers were 3.26, 3.41, and 2.86 W, while efficiencies were 24.886%, 26.027%, and 21.810%. Compared with water, 0.0005 wt% MXene increased thermal power and efficiency by 4.60% and 4.58%, whereas 0.001 wt% MXene reduced them by 12.27% and 12.36%. At 5 cm, thermal powers decreased to 2.96, 2.89, and 2.00 W, with efficiencies of 22.608%, 22.043%, and 15.232%. Both MXene configurations performed below water, with power reductions of 2.36% and 32.43% and efficiency reductions of 2.50% and 32.63%, respectively.
Increasing OFL thickness reduced useful thermal power and thermal efficiency for all three media. When thickness increased from 1 to 5 cm, thermal power decreased by 24.49% for water, 32.48% for 0.0005 wt% MXene, and 52.04% for 0.001 wt% MXene. The corresponding thermal-efficiency reductions were 24.39%, 32.58%, and 52.12%. The greater reduction at higher concentration indicates that stronger filtration did not necessarily improve useful heat recovery. A thicker OFL increases both the optical path length and fluid thermal mass, which can change the distribution of absorbed radiation and delay heat transfer during the test. Radiation absorbed within the OFL was therefore not necessarily recovered through the rear cooling circuit. Within the tested range, the 1 cm, 0.0005 wt% MXene configuration provided the highest thermal power and thermal efficiency.
5.4. Effect of MXene concentration and filter thickness on overall power output and efficiency
The overall energy performance was evaluated by combining the electrical and useful thermal outputs. At an OFL thickness of 1 cm, water, 0.0005 wt% MXene, and 0.001 wt% MXene achieved overall powers of 5.16, 5.42, and 4.89 W, with overall efficiencies of 39.35%, 41.37%, and 37.30%, respectively. Compared with water, 0.0005 wt% MXene increased overall power by 5.04% and overall efficiency by 5.15%. Its thermal-power gain of 0.36 W exceeded its electrical-power loss of 0.10 W, resulting in a net improvement of 0.26 W. In contrast, 0.001 wt% MXene reduced overall power and overall efficiency by 5.23% and 5.22%, respectively, because its thermal improvement was insufficient to compensate for the electrical loss. At 3 cm, the corresponding overall powers were 4.31, 4.22, and 3.05 W, with overall efficiencies of 32.88%, 32.18%, and 23.29%. Relative to water, the two MXene configurations reduced overall power by 2.09% and 29.23% and overall efficiency by 2.13% and 29.16%. At 5 cm, overall powers decreased to 3.83, 3.40, and 2.06 W, while overall efficiencies fell to 29.21%, 25.92%, and 15.68%, respectively. Both MXene configurations performed below water, with overall-power reductions of 11.23% and 46.21% and overall-efficiency reductions of 11.29% and 46.31%.
Increasing OFL thickness reduced overall power and overall efficiency for all three media. When thickness increased from 1 to 5 cm, overall power decreased by 25.78% for water, 37.27% for 0.0005 wt% MXene, and 57.87% for 0.001 wt% MXene. The corresponding overall-efficiency reductions were 25.76%, 37.36%, and 57.95%. These results show that the benefit of MXene addition depended on both concentration and OFL thickness. At 1 cm, the thermal improvement provided by the dilute nanofluid compensated for its relatively small electrical loss. At greater thicknesses, stronger optical attenuation reduced electrical generation, while useful thermal recovery also declined. Therefore, stronger absorption within the OFL did not necessarily improve overall energy performance. Within the tested range, the 1 cm, 0.0005 wt% MXene configuration provided the most favorable electrical–thermal balance, achieving the highest overall power of 5.42 W and overall efficiency of 41.37%.
6. Conclusion
In this investigation, the authors developed a MXene nanofluid-based spectral filtering PV/T system and experimentally evaluated the effects of MXene concentration (0.0005 wt% and 0.001 wt%) and optical filtering layer thickness (1, 3, and 5 cm) on the photovoltaic performance, thermal energy recovery capability, and overall energy conversion efficiency of the system. By analyzing solar spectrum modulation and heat transfer behavior, the authors uncovered the mechanisms through which MXene concentration and filtering layer thickness influence the energy conversion performance of the PV/T system. The main conclusions were summarized as follows:
- The MXene concentration and OFL thickness jointly determine the balance between electrical and thermal performance. A lower PV surface temperature resulting from stronger optical attenuation does not necessarily improve electrical efficiency.
- The optical filtering layer thickness significantly influenced the distribution of solar energy between photovoltaic conversion and thermal energy recovery. Increased OFL thickness reduced electrical output and useful thermal recovery under the tested conditions, while generally lowering the average PV surface temperature.
- MXene concentration exhibited a dual influence on the performance of the PV/T system. An appropriate MXene concentration enhanced solar spectral absorption and improved thermal energy utilization, whereas excessive MXene loading caused excessive optical attenuation and reduced the solar radiation available for photovoltaic conversion. At OFL thickness of 1 cm, within the investigated concentration range, the 0.0005 wt% MXene nanofluid achieved a favorable balance between thermal enhancement and electrical output preservation, while the 0.001 wt% MXene nanofluid resulted in a considerable reduction in photovoltaic performance due to excessive optical absorption.
- At OFL thickness of 1 cm, a filtration layer with a concentration of 0.0005 wt% yields an electrical power of 1.14 W and a thermal power of 4.28 W, resulting in a total power of 5.42 W. Compared to pure water, the thermal power increases by approximately 9.2%, which compensates for an 8.1% loss in electrical power, leading to an overall increase in overall power of approximately 5.0%.
- The experimental results primarily reflect system performance under the specified irradiation conditions and during the test period, limiting a comprehensive assessment of the effects of solar irradiance and ambient temperature. Future studies could extend the testing duration and incorporate outdoor experiments under variable natural solar irradiation to further clarify the relationship between optical attenuation and useful thermal recovery.
Declarations
Author contributions. Ziyan Sun: Writing (original draft), Methodology. Xianlong Shi: Data curation. Yuanlong Cui: Methodology, Supervision, Conceptualization.
Funding. This work was financially supported by the Natural Science Foundation Project of Shandong Province (Project Number: ZR2023ME121).
Conflicts of interest. The authors declare no competing interests.
Data availability. The data that support the findings of this study are available from the corresponding author upon reasonable request.
References
- Anwer, Shoaib; Alazzam, Anas; Abu-Nada, Eiyad (2025) 'Engineering and Optimization of Stable 2-Dimensional MXene-Based Nanofluid for Direct Absorption Photothermal Energy Conversion', Energy Material Advances, 6, pp. 0153. Available at: https://doi.org/10.34133/energymatadv.0153
- Cai, Yong; Dai, Yuying; Ma, Yue; Wang, Gang; Xu, Guanghui; Ren, Xingang; Wang, Hui; Zhao, Xiaohu; Wu, Xianliang (2025) 'Optically transparent transmissive orbital angular momentum (OAM) metasurface with high transmittance and broadband characteristics', Optics Express, 33(12), pp. 24385. Available at: https://doi.org/10.1364/oe.560640
- Cui, Yuanlong; Tian, Shuangqing; Zhu, Jie (2025) 'Experimental study of liquid optical filtration PV/T modules with different working fluids', Renewable Energy, 246, pp. 122893. Available at: https://doi.org/10.1016/j.renene.2025.122893
- Cui, Yuanlong; Sun, Ziyan; Wang, Xiaohang; Tian, Shuangqing; Zhu, Jie (2026) 'Numerical and experimental studies of a hybrid PV/T module with optical filtration layer for efficient solar energy harvesting', Energy, 362, pp. 142199. Available at: https://doi.org/10.1016/j.energy.2026.142199
- Dashtbozorg, Amirhosein; Safarianbana, Behnaz; Shanbedi, Mehdi (2025) 'Enhancing PV/T systems performance: A comprehensive study on MXene/methanol nanofluid in two-phase closed thermosyphons', Solar Energy Materials and Solar Cells, 279, pp. 113274. Available at: https://doi.org/10.1016/j.solmat.2024.113274
- Herrando, María; Wang, Kai; Huang, Gan; Otanicar, Todd; Mousa, Osama Bany; Agathokleous, Rafaela A.; Ding, Yulong; Kalogirou, Soteris; Ekins-Daukes, Ned; Taylor, Robert A.; Markides, Christos N. (2023) 'A review of solar hybrid photovoltaic-thermal (PV-T) collectors and systems', Progress in Energy and Combustion Science, 97, pp. 101072. Available at: https://doi.org/10.1016/j.pecs.2023.101072
- Jiao, Yue; Xing, Meibo; Estellé, Patrice (2024) 'Efficient utilization of hybrid photovoltaic/thermal solar systems by nanofluid-based spectral beam splitting: A review', Solar Energy Materials and Solar Cells, 265, pp. 112648. Available at: https://doi.org/10.1016/j.solmat.2023.112648
- Lee, Jae Won; Song, Min Soo; Jung, Han Sol; Kang, Yong Tae (2023) 'Development of solar radiation spectrum-controlled emulsion filter for a photovoltaic-thermal (PVT) system', Energy Conversion and Management, 287, pp. 117087. Available at: https://doi.org/10.1016/j.enconman.2023.117087
- Rahmanian, S.; Hamzavi, A. (2020) 'Effects of pump power on performance analysis of photovoltaic thermal system using CNT nanofluid', Solar Energy, 201, pp. 787-797. Available at: https://doi.org/10.1016/j.solener.2020.03.061
- Rubbi, Fazlay; Habib, Khairul; Saidur, R.; Aslfattahi, Navid; Yahya, Syed Mohd; Das, Likhan (2020) 'Performance optimization of a hybrid PV/T solar system using Soybean oil/MXene nanofluids as A new class of heat transfer fluids', Solar Energy, 208, pp. 124-138. Available at: https://doi.org/10.1016/j.solener.2020.07.060
- Sanjeevi, Baskar; Loganathan, Karikalan (2020) 'Synthesis of multi wall carbon nanotubes nanofluid by using two step method', Thermal Science, 24(1 Part B), pp. 519-524. Available at: https://doi.org/10.2298/tsci190414430s
- Srinivasan, Nanda kumar; Ponnusamy, Chandrasekaran (2025) 'Impact of surfactant groups on the stability, thermophysical and phase change characteristics of water-based single and hybrid nanofluid PCMs for cool energy storage applications', Thermal Science and Engineering Progress, 59, pp. 103298. Available at: https://doi.org/10.1016/j.tsep.2025.103298
- Taylor, Robert A; Otanicar, Todd; Rosengarten, Gary (2012) 'Nanofluid-based optical filter optimization for PV/T systems', Light: Science & Applications, 1(10), pp. e34-e34. Available at: https://doi.org/10.1038/lsa.2012.34
- Wang, Hao; Li, Xiaoke; Luo, Boqiu; Wei, Ke; Zeng, Guangyong (2021) 'The MXene/water nanofluids with high stability and photo-thermal conversion for direct absorption solar collectors: A comparative study', Energy, 227, pp. 120483. Available at: https://doi.org/10.1016/j.energy.2021.120483
- Wang, Gang; Liu, Jialin; Zou, Tianlin; Han, Wei; Chen, Zeshao (2025) 'Design and performance evaluation of a novel solar concentration PVT system with dual-runner nanofluids optical filtering', Energy, 340, pp. 139259. Available at: https://doi.org/10.1016/j.energy.2025.139259
- Xia, Xiaokang; Cao, Xuhui; Li, Niansi; Yu, Bendong; Liu, Huifang; Ji, Jie (2023) 'Study on a spectral splitting photovoltaic/thermal system based on CNT/Ag mixed nanofluids', Energy, 271, pp. 127093. Available at: https://doi.org/10.1016/j.energy.2023.127093
- Xing, Meibo; Jiao, Yue; Chen, Hongbing (2024) 'Tunable electrical/thermal output performance of the PV/T system with magnetic nanofluid based spectral beam filter', Energy Conversion and Management, 319, pp. 118951. Available at: https://doi.org/10.1016/j.enconman.2024.118951
- Yadav, Satish Kumar; Vishnu Varma, K.S.; Khatoon, Sidra; Chakraborty, Vishwadeep; Singh, Jyotsna; Singh, Rajendra Bahadur; Hasnain, S.M. Mozammil; Zairov, Rustem (2024) 'Ray tracing design-optimization & experimental validation of water based optical filter to reduce solar PV module heating', Case Studies in Thermal Engineering, 63, pp. 105271. Available at: https://doi.org/10.1016/j.csite.2024.105271
- Zeng, Wengao; Ye, Xiaoyuan; Dong, Yuchen; Zhang, Yuqi; Sun, Chengzhuo; Zhang, Tuo; Guan, Xiangjiu; Guo, Liejin (2024) 'MXene for photocatalysis and photothermal conversion: Synthesis, physicochemical properties, and applications', Coordination Chemistry Reviews, 508, pp. 215753. Available at: https://doi.org/10.1016/j.ccr.2024.215753
How to cite this article
Sun, Z., Shi, X. and Cui, Y. (2026). 'Experimental Investigation of the Effects of MXene Concentration and Optical Filter Layer Thickness on PV/T System Performance'. SET Proceedings, 22, pp. 82-94. https://doi.org/10.65582/set.2026.007