Experimental energy analysis of a trigeneration system based on outdoor air temperature: a case study at Fatsa State Hospital, Türkiye

,

1Hitit University, Faculty of Engineering and Natural Sciences, Department of Mechanical Engineering, 19030 Çevreyolu, Çorum, Türkiye

2Hitit University, Construction Works Department, 19030 Çevreyolu, Çorum, Türkiye

Open accessCC BY 4.0Published 23 Nov 2026https://doi.org/10.65582/set.2026.005
Download PDF20 pages · 7.7 MB

Abstract

In addition to electricity generation, trigeneration systems produce cooling energy from waste heat for air conditioning in summer and heating energy to meet part of the heating needs of spaces in winter. Because they recover waste energy, the use of trigeneration systems is increasing, especially in central heating systems and government buildings. Because waste heat is recovered, less energy is used, carbon emissions are reduced, and, consequently, trigeneration systems significantly mitigate global warming. In this real-time case study, temperature, pressure, relative humidity, and flow rate were measured from the trigeneration system of Fatsa State Hospital during the winter months at varying outdoor air temperatures. The changes in the amount of electricity and heat energy produced by the trigeneration system's gas engine, the air and fuel flow rate entering the gas engine, the air-fuel ratio, the relative humidity of the air, the engine's thermal capacity, capacity of high temperature heat exchanger (HET), capacity of hot water heat exchanger (HWE) and the engine's mechanical and thermal efficiencies were investigated at outside air temperatures ranging from 10 °C to 20 °C. For this purpose, a computer program was developed using EES (Engineering Equation Solver) software. It was observed that the heat power generated by the trigeneration system ranged from 427.1 kW to 433.2 kW, while the electrical power remained constant at 400 kW. Based on these powers, the average thermal and electrical efficiencies were 41% and 44%, respectively. Due to the increase in outside air temperature, the density of natural gas decreased, resulting in a reduction in the total heating value of the fuel from 997.8 kW to 954.5 kW.

Keywords. Trigeneration system; Gas engine; Electricity generation; Heat recovery

© 2026 The Author(s). Published by Caravel Press.

Anyone may read, download, copy, distribute and build on this article, in any medium or format, provided the authors and the original article are credited. Read the CC BY 4.0 licence

← SET Proceedings