Conference paper
Design and performance analysis of a CO2 heat pump thermal storage system decoupled from a coal-fired power plant
, , ,
1School of Energy Science and Engineering, Central South University, Changsha, Hunan, China
2Institute of Science and Technology, China Three Gorges Corporation, Beijing, China
* Correspondence: Wen Su, [email protected]
History
Received
11 Apr 2026
Revised
11 May 2026
Accepted
21 May 2026
Published
23 Nov 2026
Received to published in 226 days·Pages 69-81
Abstract
Keywords. CFPP; CO₂ heat pump; Thermal energy storage; Thermodynamic analysis
1. Introduction
Nowadays, the rapid deployment of renewable energy accelerated the transition toward carbon-neutral energy systems. However, the intermittent and fluctuating nature of wind and solar power increased the mismatch between electricity supply and demand, creating growing requirements for grid flexibility and large-scale energy storage technologies (International Energy Agency 2024a; International Energy Agency 2024b; Dunn et al. 2011; Luo et al. 2015). At the same time, coal-fired power plants (CFPPs) still accounted for a significant share of electricity generation in many countries and were increasingly required to provide peak-shaving and load-following services rather than operating solely at base load (Liu et al. 2025). Nevertheless, conventional CFPPs were designed for stable operation near rated conditions, and frequent deep-load regulation might result in efficiency degradation, increased fuel consumption, and operational constraints (Xu et al. 2025; Fang et al. 2025). Therefore, integrating energy storage systems with CFPPs was widely regarded as an effective approach to improve operational flexibility and facilitate renewable energy integration (Richter et al. 2019; Zhang et al. 2022a).
Among various technologies, thermal energy storage coupled with CFPPs attracted extensive attention because it could partially decouple heat production from electricity generation. Molten-salt thermal storage was one of the most widely studied options due to its high heat capacity, low storage cost, and mature engineering experience (Liu et al. 2025; Zhang et al. 2022a; Bauer et al. 2013; Zhang et al. 2022b). Previous studies demonstrated that thermal storage integration could significantly reduce the minimum technical output of CFPPs and enhance peak-shaving capability (Liu et al. 2025; Zhang et al. 2022a). However, direct thermal storage often suffered from heat-source and storage-temperature mismatches, leading to exergy destruction and limiting the utilization efficiency of thermal energy (Wang et al. 2025; Yan et al. 2026).
Heat pump energy storage (HPES), also known as a Carnot battery, emerged as a promising solution for converting electricity into thermal energy and recovering it when needed (Vecchi et al. 2022; Dumont et al. 2020; Novotny et al. 2022). Compared with direct electric heating, HPES could achieve a higher round-trip efficiency (RTE) by upgrading low-grade heat to a higher temperature level. In particular, CO2 heat pumps attracted increasing interest because CO2 was environmentally friendly and exhibited favorable heat-transfer characteristics under transcritical conditions, enabling effective temperature matching with sensible thermal storage media (Adamson et al. 2022; Aga et al. 2016; Shamsi et al. 2024). Therefore, integrating CO2 heat pumps with CFPPs provided a promising pathway for enhancing flexibility and accommodating surplus renewable electricity.
However, most existing studies employed direct coupling between the heat pump and the CFPP. In such configurations, the operation of the heat pump relied on the instantaneous availability of extraction steam, exhaust steam, or flue-gas heat from the power plant. Consequently, the charging process remained strongly constrained by the operating state of the CFPP, limiting the ability of the storage system to respond independently to fluctuating renewable-electricity availability. A decoupled configuration was therefore desirable, in which low-grade heat from the CFPP was first stored in an intermediate thermal storage unit, allowing the CO2 heat pump to operate independently according to renewable-electricity availability rather than the real-time load condition of the power plant.
To address the intermittency of wind and solar energy, and improve the renewable energy accommodation capability of CFPP-based power systems, a CO2 HPES system decoupled from a CFPP was proposed in this work. In the proposed system, low-pressure extraction steam was used to store heat in a low-temperature water tank. This low-temperature thermal storage unit acted as an intermediate heat buffer between the CFPP and the CO2 heat pump. Based on the proposed decoupled configuration, a thermodynamic model was established to evaluate the performance of the integrated system under variable CFPP loads, and the thermodynamic characteristics and key design parameters were investigated.
2. System description
To retrofit existing CFPPs for deep peak-shaving operation, a decoupled CO2 HPES system was proposed, as illustrated in Figure 1. The boundary conditions and component parameters of the CFPP model were obtained from the design data of a 600 MW supercritical unit at Zhuanghe Power Plant in Dalian, China. The proposed system consisted of four main subsystems: the original CFPP, a steam-extraction thermal storage subsystem, a CO2 heat pump subsystem, and a molten-salt thermal storage subsystem. By introducing an intermediate low-temperature water-storage subsystem between the CFPP and the CO2 heat pump, the operation of the heat pump was decoupled from the instantaneous operating condition of the power plant, enabling flexible utilization of surplus electricity from both renewable energy and the CFPP.
In the steam-extraction thermal storage subsystem, part of the fifth-stage low-pressure extraction steam was diverted from the regenerative system to heat storage water. The heated water was stored in dedicated water tanks and served as an intermediate low-temperature thermal reservoir. Compared with conventional directly coupled configurations, this arrangement allowed low-grade thermal energy from the CFPP to be stored independently and utilized by the heat pump when electricity was available, thereby reducing the dependence of the charging process on the real-time operating condition of the power plant. The CO2 heat pump upgraded the stored low-temperature thermal energy to a higher temperature level and transferred it to the molten-salt thermal storage subsystem. Owing to the favorable temperature-matching characteristics of transcritical CO2 heat pumps, efficient heat transfer between the storage water and molten salt could be achieved. The molten salt acted as the high-temperature thermal storage medium and provided the thermal energy required during the discharging process.
The integrated system operated in three periods: charging, normal-operation, and discharging modes. During the charging process, the CFPP operated at a low load, typically 30% turbine heat acceptance (THA), and low-grade heat from the fifth-stage extraction steam was first stored in the water-storage subsystem. The stored heat was then upgraded by the CO2 heat pump and transferred to the molten-salt thermal storage system using surplus electricity. During normal operation, the CFPP operated flexibly under conventional regenerative conditions. During the discharging process, the thermal energy stored in the molten-salt tanks was released to heat the feedwater and reheat steam, generating additional superheated steam and increasing the turbine output during peak-demand periods. In this way, the proposed system enhanced the operational flexibility and peak-shaving capability of the CFPP while improving the utilization of surplus renewable electricity.
Owing to the proposed decoupled configuration, three low-load power regulation modes could be realized. In Mode 1, only the steam extraction thermal storage subsystem operated, and low-pressure extraction steam was used to charge the water storage subsystem for deep peak shaving. In Mode 2, only the CO2 heat pump operated using surplus CFPP electricity or renewable energy to upgrade low-temperature stored heat into high-temperature thermal energy in the molten salt storage system. In Mode 3, the steam extraction subsystem and the CO2 heat pump operated simultaneously, combining steam extraction and electrical energy consumption to maximize the charging capability. These operating modes significantly improved the flexibility of the proposed system under different grid regulation and renewable energy accommodation scenarios.
3. Thermodynamic modeling
The thermodynamic model was developed under steady-state conditions. Changes in kinetic and potential energies were neglected, and all heat exchangers were assumed to operate in counter-current flow. The turbine, CO2 compressor, expander, and pumps were modelled using specified isentropic efficiencies. Pressure drops in pipes and heat exchangers were neglected; therefore, the pressure at the outlet of each heat exchanger was assumed to be equal to that at the corresponding inlet. Heat losses from pipes, heat exchangers, water-storage tanks, and molten-salt tanks were neglected in the base-case calculation.
3.1. Energy model
CFPP
For the high-pressure heaters (HPHs), the MTBE-based thermal balance formula was shown as Eq. (1) (Hou et al. 2024):
For the low-pressure heaters (LPHs), the MTBE-based thermal balance formula was shown as Eq. (2):
Where:
- mi (i=1~8) = mass flow rate of the i-th extraction steam (kg/s);
- γi (i=1~8) = drain enthalpy drop of the i-th feedwater heater (kJ/kg);
- τi (i=1~8) = feedwater enthalpy rise of the i-th feedwater heater (kJ/kg);
- qi (i=1~8) = heat released by extraction steam in the i-th feedwater heater (kJ/kg);
- mfwh = mass flow rate of feedwater in HPHs (kg/s);
- mfwl = mass flow rate of feedwater in low-pressure feedwater heaters (LPHs) (kg/s).
For each surface-type feedwater heater except the deaerator, the required parameters γi, τi, and qi were defined as Eq. (3):
Where:
- hd(i-1) = inlet specific enthalpy of drain water in the i-th feedwater heater (kJ/kg);
- hdi = outlet specific enthalpy of drain water in the i-th feedwater heater (kJ/kg);
- hei = specific enthalpy of the i-th extraction steam (kJ/kg);
- hfw(i+1) = inlet specific enthalpy of feedwater in the i-th feedwater heater (kJ/kg);
- hfwi = outlet specific enthalpy of feedwater in the i-th feedwater heater (kJ/kg).
For the deaerator, the corresponding expressions for γi, τi, and qi were defined by Eq. (4):
Based on the mass and energy balance equations, the turbine power output Ptur, boiler heat input Qb, and net power output of the integrated system Pnet could be calculated.
Additionally, for the turbine-generator unit operating under off-design conditions, the relationship between steam parameters and mass flow rates satisfied the Flügel formula, which was expressed as Eq. (5):
Where:
- pin,ref, pout,ref, Tin,ref, mref = turbine inlet pressure (kPa), outlet pressure (kPa), inlet temperature (K), and mass flow rate (kg/s) under reference operating condition, respectively;
- pin,var, pout,var, Tin,var, mvar = turbine inlet pressure (kPa), outlet pressure (kPa), inlet temperature (K), and mass flow rate (kg/s) under off-design condition, respectively.
Based on the above CFPP model, the steam-extraction thermal storage subsystem was further modeled using the corresponding mass and energy balances. During charging, Pump 3 circulated the storage water through the steam–water heat exchanger. Its electricity consumption was calculated as Eq. (6):
Where:
- msw,CFPP = mass flow rate of storage water during steam-extraction thermal storage (kg/s);
- H= head of pumps (m);
- g = gravitational acceleration (m/s²);
- ηps= isentropic efficiency of pumps;
- ηm= mechanical efficiency;
- ηg = generator efficiency.
CO2 heat pump
The energy balance equations for key components of the CO2 heat pump were summarized in Table 1. During system operation, both molten salt and storage water exchanged heat with CO2. Accordingly, the circulation pumps supporting the operation, namely Pump 2 and Pump 4, were also mathematically modeled and presented in Table 1.
Table 1. Energy balance equations for each component of the CO2 heat pump.
| Component | Equation |
|---|---|
| Compressor | |
| Heat exchanger 1 | |
| Heat exchanger 2 | |
| Regenerator | |
| Expander | |
| Pump 2 | |
| Pump 4 |
For the compressor, the isentropic outlet state 2s was first determined from p2 and s2s=s1. The actual outlet enthalpy was then calculated using the compressor isentropic efficiency, as shown in Eq. (7):
For the expander, the isentropic outlet state 5s was determined from p5 and s5s=s4, and the actual outlet enthalpy was obtained from Eq. (8):
The compressor electricity consumption and expander electricity generation were further corrected using the mechanical and generator efficiencies. The design isentropic efficiencies of the compressor and expander were 0.85 and 0.87, respectively, while both the mechanical and generator efficiencies were 0.98.
To evaluate the local temperature differences, each counter-current heat exchanger was discretised into 100 control volumes, and the temperature profiles of the hot and cold streams were calculated along the heat-transfer direction.
3.2. Performance indicators
Based on the component energy balance equations in Table 1, coefficient of performance (COP) of the heat pump could be expressed as Eq. (9):
The overall gross power generation efficiency of the CFPP was defined as the ratio of the turbine power output to the total heat input to the boiler, as expressed by Eq. (10):
Where:
- Ptur = total power output of turbine (MW);
- Qb = heat input of the boiler (MW);
During the low-load charging phase, the turbine power output was reduced by steam extraction and heat-pump operation, and the minimum achievable load ratio could be expressed as Eq. (11) and Eq. (12):
During the high-load discharging phase, the power output was increased by the additional generation from the molten-salt storage system, and the maximum achievable load ratio was expressed by Eq. (13):
Where:
- Plow = net external power output of the integrated system under the minimum-load condition (MW);
- λCFPP = load ratio of standalone CFPP without energy storage, ranging from 30% to 100%;
- Prated = rated power capacity of the CFPP (MW);
- PLPH5,loss = power loss induced by the fifth-stage extraction steam (MW);
- Wp4, Wp2 = power consumption of water pump and molten salt pump (MW), respectively;
- λmin,es, λmax,es = minimum and maximum achievable external power supply ratios of the CFPP integrated with energy storage system, respectively;
- ΔPnet = incremental net power output during discharge after deducting all additional auxiliary power consumption associated with the molten-salt thermal energy storage system (MW).
To evaluate the overall performance of the integrated thermal energy storage system, the RTE boundary included the steam-extraction thermal storage subsystem, the CO2 heat pump, the water and molten-salt circulation pumps, and the additional power-generation process during discharge. The charging energy included the equivalent power loss caused by fifth-stage steam extraction, the net electricity consumption of the CO2 heat pump, and the associated pump consumption. The discharge energy was defined as the incremental net electricity output relative to the standalone CFPP at the same baseline THA load. Heat losses from the storage tanks and pipelines were neglected under the steady-state adiabatic assumption, as expressed in Eq. (14), (15) and (16).
Where:
- Echar = energy consumption in the charging process (MWh);
- Edis = total net electricity output in the discharging process (MWh);
- tex = extraction heat storage hours (h);
- thp = heat pump operation hours (h);
- tms = molten salt generation hours (h).
4. Working conditions
The detailed design conditions were summarized in Table 2. It should be noted that the thermophysical properties of CO2 and water were evaluated using REFPROP through a MATLAB interface. Enthalpy, entropy, density, and specific heat capacity were calculated as functions of temperature and pressure at each state point. The CO2 compressor and expander outlet states were determined from the corresponding isentropic reference states and the specified isentropic efficiencies. The REFPROP reference-state convention was used consistently throughout the calculation. In addition, solar salt consisting of 60% NaNO3 and 40% KNO3 was adopted as the high-temperature storage medium. Its density and specific heat capacity were calculated using the temperature-dependent correlations reported by D’Aguanno et al. (2018). In the following correlations, T is expressed in K, ρ in kg/m3, and cp in J/(kg·K).
Table 2. Thermodynamic and operational design parameters of the system.
| Category | Parameter | Value |
|---|---|---|
| CFPP | Geographic position | 38.9°N; 121.6°E |
| Rated power output / MW | 600 | |
| Boiler feedwater temperature / °C | 275 | |
| Boiler feedwater pressure / MPa | 28.87 | |
| Boiler efficiency / % | 93.83 | |
| Mechanical efficiency ηm / % | 98 | |
| Generator efficiency ηg / % | 98 | |
| Isentropic efficiency of pumps ηps / % | 85 | |
| Inlet steam temperature of HPT and IPT / °C | 566 | |
| Inlet pressure of HPT / MPa | 24.2 | |
| Inlet pressure of IPT / MPa | 3.81 | |
| Extraction steam and heat storage subsystem | Extraction heat storage hours tex / h | 8 |
| Low-pressure 5th extraction steam ratio / % | 5 | |
| Low-pressure 5th extraction steam saturation temperature / °C | 72 | |
| Hot storage water pool temperature / °C | 70 | |
| Hot storage water pool pressure / MPa | 1 | |
| Cold storage water pool temperature / °C | 10 | |
| CO2 heat pump | Heat pump operation hours thp / h | 8 |
| Compressor inlet temperature / °C | 400 | |
| Compressor inlet pressure / MPa | 2 | |
| Isentropic efficiency of compressor / % | 85 | |
| Isentropic efficiency of CO2 expander / % | 87 | |
| Hot molten salt tank temperature / °C | 580 | |
| Cold molten salt tank temperature / °C | 320 | |
| Molten salt generation hours tms / h | 5 | |
| Property of molten salt (D’Aguanno et al. 2018) | Density / kg/m3 | |
| Specific heat capacity / J/(kg·K) |
5. Results and discussion
Based on the reference-condition parameters, the thermodynamic and peak-shaving performances of the proposed system were evaluated. The charging process was performed at 30% THA, while the discharging process was analyzed under 30%, 50%, 75%, and 100% THA operating conditions. Key performance indicators, including power output, peak-shaving capability, RTE, and coal consumption rate, were calculated and compared. Since THA was widely adopted in power plant engineering to represent unit load levels relative to the rated condition, it was used throughout the following analysis.
As shown in Figure 2, the peak-shaving performance of the HPES-power plant was evaluated under different charging and discharging conditions. The red bars denoted the reference load under matched charging and discharging conditions, where both charging and discharging were performed at the same THA load. This reference case served as a benchmark to quantify the improvement in peak-shaving capability achieved by the proposed operation strategy under mismatched charging and discharging conditions. The red line indicated the maximum and minimum peak-shaving capability achievable under these matched operating conditions. The minimum load shown by the red line corresponded to Mode 3 operation, in which steam extraction and heat pump charging were simultaneously employed, thereby providing the strongest peak-shaving capability among the three charging modes. In contrast, the blue line represented the maximum achievable peak-shaving load under a fixed charging load of 30% THA, with discharging loads of 30%, 50%, 75%, and 100% THA. Additionally, under the 30% THA charging scenario, ηgen ranged from 33.98% to 45.15%, and the RTE ranged from 44.29% to 58.09%.
As shown in Figure 3, the coal consumption rates of the HPES-power plant under different operating conditions were further analyzed. The red bars represented the coal consumption rates under matched charging and discharging loads, while the line denoted by bnormal corresponded to the coal consumption rate under a fixed 30% THA charging condition with different discharging loads, when peak-shaving operation was not considered. Additionally, the line denoted by bvar represented the coal consumption rate when peak-shaving operation was considered under the same charging condition.
From Figure 3, it could be observed that compared with the normal operating condition, the coal consumption rate was higher under peak-shaving operation. Nevertheless, the system still maintained acceptable thermodynamic performance under the 30% THA charging scenario while providing considerable peak-shaving capability. Combined with the results presented in Figure 2, this demonstrated the necessity and practical feasibility of adopting the 30% THA charging condition. Therefore, the subsequent reference-condition analyses were carried out based on the 30% THA charging case, with the 50% THA discharging condition selected as the reference operating case. This choice was motivated by the fact that CFPPs generally operated around a medium-load level during long-term operation, making 50% THA a representative condition for assessing the performance of the proposed system.
Table 3 presented the thermodynamic performance of the system under the reference condition of 30% THA charging and 50% THA discharging. During the charging process, the steam extraction thermal storage subsystem and the CO2 heat pump operated simultaneously (Mode 3), representing the maximum charging capacity scenario considered in this study. Under this condition, the system achieved a COP of 1.32 and an RTE of 53.41%, while the generation efficiency reached 39.62%. In addition, the coal consumption rates under normal and peak-shaving conditions were 335.66 g/(kW·h) and 388.36 g/(kW·h), respectively. The corresponding molten salt and water storage capacities were also summarized in the table, providing a quantitative description of the storage requirements under the reference operating condition.
Table 3. Thermodynamic performance of the system under reference operating condition.
| Parameter | Value |
|---|---|
| COP | 1.32 |
| RTE / % | 53.41 |
| ηgen / % | 39.62 |
| λmin,es of Mode 1 / % | 29.72 |
| λmin,es of Mode 2 / % | 12.44 |
| λmin,es of Mode 3 / % | 12.16 |
| λmax,es / % | 65.24 |
| bnormal / g/(kW·h) | 335.66 |
| bvar / g/(kW·h) | 388.36 |
| Mms / t | 1.02×104 |
| Vms,total / m3 | 5.68×103 |
| Msw / t | 3.82×103 |
| Vsw,total / m3 | 7.73×103 |
Furthermore, under the reference operating condition, the calculated minimum approach temperature differences of heat exchanger 1, heat exchanger 2, and the regenerator were 19.0, 10.0, and 18.5 K, respectively. No internal temperature crossover occurred in any of the heat exchangers.
6. Conclusion
To address the intermittency of renewable energy and enhance the flexibility and peak-shaving capability of CFPPs, a CO2 HPES system decoupled from a CFPP was proposed in this study. The charging and discharging processes were effectively decoupled through a storage water subsystem, enabling flexible energy management and independent operation of the heat pump and power generation units.
Based on the established thermodynamic models, the performance of the proposed system under the reference operating condition was investigated. The results showed that, under the reference operating conditions of 30% THA charging and 50% THA discharging, the CO2 heat pump achieved a COP of 1.32, while the overall system attained an RTE of 53.41%. The corresponding minimum and maximum peak-shaving load ratios were 12.16% and 65.24%, respectively, demonstrating the capability of the proposed system to significantly enhance the operational flexibility of the CFPP. When peak-shaving operation was considered, the coal consumption rate was 388.36 g/(kW·h). In addition, the required volumes of the molten salt storage tanks and storage water pools were 5.68×103 m3 and 7.73×103 m3, respectively. These results indicated that the proposed system could effectively achieve deep peak shaving while maintaining favorable thermodynamic performance, providing a promising solution for enhancing CFPP flexibility and accommodating renewable energy.
Although the proposed system demonstrated promising thermodynamic performance, several limitations remained. First, the thermodynamic model was developed under steady-state conditions with several simplifying assumptions, including negligible pressure drops and heat losses. Although the CFPP boundary conditions and component parameters were obtained from the design data of the reference plant, comprehensive validation against multi-load operational data was not conducted because such data were unavailable for the present study. In addition, the dynamic operating characteristics and control strategies of the system under actual grid fluctuations, as well as its coupling with variable renewable energy sources, were not fully considered. Future work will therefore focus on validation using measured plant data, dynamic simulation, operating-strategy optimisation, and the integration of the proposed system with large-scale renewable energy to further improve its flexibility, stability, and practical applicability.
Declarations
Author contributions. Tengjiao Jia: Writing (original draft), Methodology, Investigation, Formal analysis, Conceptualization. Wen Su: Funding acquisition, Writing (review and editing), Validation, Methodology, Conceptualization, Supervision. Xinxing Lin: Writing (review and editing), Validation, Methodology, Conceptualization. Zhimei Zheng: Supervision, Methodology.
Funding. The authors would like to acknowledge the funding support by the Key R&D Project of Hunan Province (2025WK2007).
Awards. Department of Science and Technology of Hunan Province (2025WK2007)
Conflicts of interest. The authors declare no competing interests.
Data availability. Not applicable. This study did not generate or analyse any datasets.
References
- Adamson, Keri-Marie; Walmsley, Timothy Gordon; Carson, James K.; Chen, Qun; Schlosser, Florian; Kong, Lana; Cleland, Donald John (2022) 'High-temperature and transcritical heat pump cycles and advancements: A review', Renewable and Sustainable Energy Reviews, 167, pp. 112798. Available at: https://doi.org/10.1016/j.rser.2022.112798
- Aga, Vipluv; Conte, Enrico; Carroni, Richard; Burcker, Bertrand; Ramond, Mathieu (2016) 'Supercritical CO2-based heat pump cycle for electrical energy storage for utility scale dispatchable renewable energy power plants', Proceedings of the 5th International Symposium on Supercritical CO2 Power Cycles, San Antonio, Texas. Available at: https://www.sco2symposium.com/papers2016/Thermal/094paper.pdf
- Bauer, Thomas; Pfleger, Nicole; Laing, Doerte; Steinmann, Wolf-Dieter; Eck, Markus; Kaesche, Stefanie (2013) 'High-Temperature Molten Salts for Solar Power Application', Molten Salts Chemistry. Elsevier, pp. 415-438. Available at: https://doi.org/10.1016/b978-0-12-398538-5.00020-2
- D’Aguanno, B.; Karthik, M.; Grace, A. N.; Floris, A. (2018) 'Thermostatic properties of nitrate molten salts and their solar and eutectic mixtures', Scientific Reports, 8(1). Available at: https://doi.org/10.1038/s41598-018-28641-1
- Dumont, Olivier; Frate, Guido Francesco; Pillai, Aditya; Lecompte, Steven; De paepe, Michel; Lemort, Vincent (2020) 'Carnot battery technology: A state-of-the-art review', Journal of Energy Storage, 32, pp. 101756. Available at: https://doi.org/10.1016/j.est.2020.101756
- Dunn, Bruce; Kamath, Haresh; Tarascon, Jean-Marie (2011) 'Electrical Energy Storage for the Grid: A Battery of Choices', Science, 334(6058), pp. 928-935. Available at: https://doi.org/10.1126/science.1212741
- Fang, Fang; Sun, Yutong; Zhang, Yi; Du, Ming; Liu, Jizhen (2025) 'Dynamic modeling and performance analysis of a coal-fired power plant integrated with flue gas-molten salt thermal energy storage system', Applied Thermal Engineering, 280, pp. 128348. Available at: https://doi.org/10.1016/j.applthermaleng.2025.128348
- Hou, Kun; Wang, Yan; Han, Ningze; Ma, Tingshan; Lv, Kai; Liu, Xiangyang; He, Maogang (2024) 'Performance analysis of a liquid carbon dioxide energy storage system integrated with a coal-fired power plant', Journal of Energy Storage, 77, pp. 109869. Available at: https://doi.org/10.1016/j.est.2023.109869
- International Energy Agency (2024a) Electricity 2024: Analysis and Forecast to 2026. Available at: https://www.iea.org/reports/electricity-2024
- International Energy Agency (2024b) Renewables 2024: Analysis and Forecast to 2030. Available at: https://www.iea.org/reports/renewables-2024
- Liu, Ming; Miao, Lin; Wang, Zhu; Yan, Junjie (2025) 'Design and thermo-economic analysis on molten salt thermal energy storage system integrated within coal-fired power plant: Co-storing energy from live and reheat steam', Journal of Energy Storage, 131, pp. 117637. Available at: https://doi.org/10.1016/j.est.2025.117637
- Luo, Xing; Wang, Jihong; Dooner, Mark; Clarke, Jonathan (2015) 'Overview of current development in electrical energy storage technologies and the application potential in power system operation', Applied Energy, 137, pp. 511-536. Available at: https://doi.org/10.1016/j.apenergy.2014.09.081
- Novotny, Vaclav; Basta, Vit; Smola, Petr; Spale, Jan (2022) 'Review of Carnot Battery Technology Commercial Development', Energies, 15(2), pp. 647. Available at: https://doi.org/10.3390/en15020647
- Richter, Marcel; Oeljeklaus, Gerd; Görner, Klaus (2019) 'Improving the load flexibility of coal-fired power plants by the integration of a thermal energy storage', Applied Energy, 236, pp. 607-621. Available at: https://doi.org/10.1016/j.apenergy.2018.11.099
- Shamsi, Syed Safeer Mehdi; Barberis, Stefano; Maccarini, Simone; Traverso, Alberto (2024) 'Large scale energy storage systems based on carbon dioxide thermal cycles: A critical review', Renewable and Sustainable Energy Reviews, 192, pp. 114245. Available at: https://doi.org/10.1016/j.rser.2023.114245
- Vecchi, Andrea; Knobloch, Kai; Liang, Ting; Kildahl, Harriet; Sciacovelli, Adriano; Engelbrecht, Kurt; Li, Yongliang; Ding, Yulong (2022) 'Carnot Battery development: A review on system performance, applications and commercial state-of-the-art', Journal of Energy Storage, 55, pp. 105782. Available at: https://doi.org/10.1016/j.est.2022.105782
- Wang, Yuanjing; Gong, Liangyong; Zhang, Yanping (2025) 'Peak shaving performance analysis of a coal-fired power plant integrated with molten salt thermal energy storage system based on energy-potential matching principle', Journal of Energy Storage, 124, pp. 116956. Available at: https://doi.org/10.1016/j.est.2025.116956
- Xu, Qilong; Wang, Shuai; Luo, Kun; Fan, Jianren (2025) 'Energy-saving retrofit and thermal economy optimization of peak-shaving for coal-fired power plants utilizing molten salt thermal storage', Applied Thermal Engineering, 280, pp. 128229. Available at: https://doi.org/10.1016/j.applthermaleng.2025.128229
- Yan, Zhiyuan; Tan, Rui; Meng, Fanxing; Jiang, Guo’an; Ren, Fengying; He, Xinrong; Zhang, Tao; Ren, Xiaohan (2026) 'Molten-Salt-Based Thermal Storage for Thermal Power Plant Peaking', Energies, 19(5), pp. 1246. Available at: https://doi.org/10.3390/en19051246
- Zhang, Kezhen; Liu, Ming; Zhao, Yongliang; Yan, Hui; Yan, Junjie (2022a) 'Design and performance evaluation of a new thermal energy storage system integrated within a coal-fired power plant', Journal of Energy Storage, 50, pp. 104335. Available at: https://doi.org/10.1016/j.est.2022.104335
- Zhang, Kezhen; Liu, Ming; Zhao, Yongliang; Zhang, Shunqi; Yan, Hui; Yan, Junjie (2022b) 'Thermo-economic optimization of the thermal energy storage system extracting heat from the reheat steam for coal-fired power plants', Applied Thermal Engineering, 215, pp. 119008. Available at: https://doi.org/10.1016/j.applthermaleng.2022.119008
How to cite this article
Jia, T., Su, W., Lin, X. and Zheng, Z. (2026). 'Design and performance analysis of a CO2 heat pump thermal storage system decoupled from a coal-fired power plant'. SET Proceedings, 22, pp. 69-81. https://doi.org/10.65582/set.2026.006