Skip to content
Caravel Press

Conference paper

Design and performance analysis of a CO2 heat pump thermal storage system decoupled from a coal-fired power plant

, , ,

1School of Energy Science and Engineering, Central South University, Changsha, Hunan, China

2Institute of Science and Technology, China Three Gorges Corporation, Beijing, China

Open accessCC BY 4.0Published 23 Nov 2026https://doi.org/10.65582/set.2026.006
Download PDF13 pages · 1013 KB

Abstract

To address the intermittency of renewable energy and enhance renewable energy integration, a CO2 heat pump thermal energy storage system decoupled from a coal-fired power plant (CFPP) was proposed. Taking a 600 MW supercritical CFPP in Dalian, China as a case study, a low-temperature water storage subsystem was introduced by utilizing fifth-stage low-pressure extraction steam, enabling the decoupling of CFPP and heat pump operations. The stored low-grade heat was subsequently upgraded by a CO2 heat pump and transferred to a molten-salt thermal energy storage system using surplus electricity from the CFPP or renewable energy sources. Based on this configuration, three charging strategies were realized, including standalone steam extraction thermal storage, standalone heat pump thermal storage, and their combined operation. Results showed that, under the 30% turbine heat acceptance (THA) charging condition, standalone steam extraction reduced the minimum operating load to 29.72% THA, while the combined operation mode further decreased it to 12.16% THA after 8 h of heat storage. During the discharging process, the molten salt storage system effectively increased the CFPP output, raising the operating load to 43.13%, 65.24%, 91.60%, and 117.18% THA under baseline loads of 30%, 50%, 75%, and 100% THA, respectively, without exceeding safe turbine operating limits. The corresponding power generation efficiency ranged from 33.98% to 45.15%, while the round-trip efficiency (RTE) varied between 44.29% and 58.09%. Under the reference operating condition of 30% THA charging and 50% THA discharging, the CO2 heat pump achieved a coefficient of performance (COP) of 1.32, and the overall system attained an RTE of 53.41%. The required volumes of the molten-salt storage tanks and storage water pools were 5.68×103 m3 and 7.73×103 m3, respectively. The results demonstrated that the proposed system could significantly extend the peak-shaving range of CFPPs and improve their adaptability to renewable energy fluctuations, providing a promising pathway for flexible operation and renewable energy accommodation.

Keywords. CFPP; CO₂ heat pump; Thermal energy storage; Thermodynamic analysis

© 2026 The Author(s). Published by Caravel Press.

Anyone may read, download, copy, distribute and build on this article, in any medium or format, provided the authors and the original article are credited. Read the CC BY 4.0 licence

← SET Proceedings