The design and application of Ground Coupled Heat Pump (GCHP) was mainly based on the heat transfer performance of underground heat exchanger. An experimental system with different types of U-vertical ground coupled heat exchanger (UGCHE) in situ was set up, for example, single or double UGCHE with sandstone backfilled, and single UGCHE with cement backfilled. The research on the thermal behaviour of UGCHE in different types, and in various conditions, such as different soil properties, backfill material, number of borehole exchangers, and different operation modes was carried out in the paper.
Keywords. U-vertical ground coupled heat exchanger (UGCHE); Heat transfer performance; Different types of UGCHE
References
Yan Gu and Dennis L. O’ Neal, Modelling the effect of backfills on U-Tube ground coil performance. ASHRAE Trans.,1998,104(2): 46-54.
Liu Xianying, Wang Yong, Hu Mingming, Wei Tangd, Experimental research on vertical buried-tube type of underground exchanger for ground source heat pump. Journal of Chongqing Jianzhu University,1999,21(5): 21-26.
Zeng Heyi, Fang zhaohong, A fluid temperature mode for Vertical U-tube geothermal heat exchangers,Journal of Shandong Institute of Architecture and Engineering, 2002,17(1): 7-11
How to cite this article
Li, X., Chen, Y., Chen, Z. and Zhao, J. (2005). 'Experimental Study on Underground Heat Exchanger with Different Types'. SET Proceedings, 4(1), pp. 490-492. https://doi.org/10.65582/set.2005.108