Skip to content
Caravel Press

Conference paper

CFD Simulation of a Double Skin Façade Model

,

1School of the Built Environment, University of Nottingham, University Park, Nottingham, NG72RD, UK

Published
30 August 2006
Pages
1-5
Received
30 August 2006
DOI
10.65582/set.2006.046
Access
Open access, © 2006 Copyright WSSET
Download PDF5 pages · 272 KB

Abstract

Double Skin Facades (DSF) are increasingly applied in office buildings. However, designers are in some aspects unaware of the overall behaviour and real performance of a DSF. In this field, relatively little has been done on thermal overheating control, specifically on the case of a façade performing under extreme or moderate summer conditions. A 3D model of the chamber was made and modelled on CFD in order to visualise the airflow within the system. The objective was the study of theoretical modelling of airflow in building façades, to complement the experimental work done in the University of Nottingham. The modelling work has demonstrated the feasibility and versatility of CFD for the modelling of double skin façades

Keywords. Active facade; thermal modelling; natural convection; multiple glazing

© 2006 Copyright WSSET

Free to read, download, print and share, unaltered and for non-commercial purposes, provided the authors, the paper and the proceedings are credited. Any other use, including commercial use or adaptation, needs written permission: write to [email protected].