Skip to content
Caravel Press

Conference paper

Evaluation of Daylight and Electrical lighting Performance in an Office Space

, , ,

1Dept. of Arch. , Korea University, Seoul, Korea

2Samoo Architects & Engineers, Seoul, Korea

Published
24 August 2008
Pages
1836-1843
Received
24 August 2008
DOI
10.65582/set.2008.255
Access
Open access, © 2008 Copyright WSSET
Download PDF8 pages · 694 KB

Abstract

In this research, lighting performance was compared with actual measured data in a case study of an office area. Various design alternatives were then analyzed in a model of the case study in order to determine the optimum conditions for saving lighting energy and improving illuminance uniformity. Requirements from LEED 2.1 & 2.2 and CASBEE were used as indexes for the evaluation. Results showed that in Case 4 (WWR: 60%, TR: 44%, OH: 150cm), direct sunlight can be controlled near the window area, satisfying the LEED 2.2 requirement. In addition, in Case 2 (WWR: 34%, TR: 82%), where 2 light fixtures near the window were switched off, optimum lighting levels and illuminance uniformity were obtained at noon on the equinox.

Keywords. daylight; electrical lighting; illuminance; illuminance uniformity

© 2008 Copyright WSSET

Free to read, download, print and share, unaltered and for non-commercial purposes, provided the authors, the paper and the proceedings are credited. Any other use, including commercial use or adaptation, needs written permission: write to [email protected].