The move towards a low-carbon world, driven partly by climate science and partly by the business opportunities it offers, will need the promotion of environmentally friendly alternatives if an acceptable stabilisation level of atmospheric carbon dioxide is to be achieved. This requires the harnessing and use of natural resources that produce no air pollution or GHGs and provides comfortable coexistence of humans, livestock, and plants. GSHPs are receiving increasing interest because of their potential to reduce primary energy consumption and thus reduce emissions of GHGs. The main objective of the research is to stimulate the uptake of the GSHPs. This paper describes the details of a prototype direct expansion GSHP test rig and details of the construction and installation of the heat pump, heat exchanger, heat injection fan and water supply system. It also presents a discussion of the experimental tests currently being carried out.
Keywords. Direct expansion GSHPs; construction; development and evaluation of the system
References
Riffat, S.B., Boukhanouf, R., and Srivastava, N.C. Design and modelling of an adsorption system for heating and cooling applications. Proceedings of the 1st International Conference on Sustainable Energy Technologies, p.70-78, Porto, Portugal, 12-14 June 2002.
ASHRAE. Commercial/Institutional Ground Source Heat Pump Engineering Manual. American Society of heating, Refrigeration and Air-conditioning Engineers, Inc. Atlanta, GA: USA. 1995.
Kavanaugh, S., Rafferty, K. Ground source heat pumps. Design of Geothermal Systems for Commercial and Institutional Buildings. American Society of heating, Refrigeration and Air-conditioning Engineers, Inc. Atlanta, GA: USA. 1997.
Austin, W.A., Yavuzturk, C. and Spitler, J.D. Development of an in situ system and analysis procedure for measuring ground thermal properties. ASRAE Transactions 106 (1). 2000.
Fetter, C.W. Determination of the direction of ground-water flow. Ground Water Monitoring Review, No. 3, pp. 28-31. 1981.
Isiorho, S.A., and Meyer, J.H. The effects of bag type and metre size on seepage metre measurements. Ground Water 37 (3): 411-413. 1999.
Freeze, R.A., and Cherry, .A. Guest Editorial — What Has Gone Wrong. Ground Water, volume 27, No. 4, July- August 1989.
Eggen, G. Ground temperature measurements. Oslo. 1990.
How to cite this article
Riffat, S.B. and Omer, A.M. (2009). 'Development and Evaluation of a Direct Expansion Heat Pump System'. SET Proceedings, 8, pp. 1-16. https://doi.org/10.65582/set.2009.007