OTEC Power systems using the Condenser Effluent from Wolsong nuclear power plant in Korea

, , , ,

1College of Engineering, Cheju National University, Jeju, Korea

2Korea Distric Hating Corporation, Il-San 411-815, KOREA

Published
31 August 2009
Pages
1-6
Received
31 August 2009
DOI
10.65582/set.2009.102
Access
Open access, © 2009 Copyright WSSET
Download PDF6 pages · 300 KB

Abstract

There has been increasing interest in clean energy over past few years. Ocean Thermal Energy Conversion(OTEC) power plants have been examined as a viable option for supplying clean energy. This paper evaluated the thermodynamic performance of the OTEC Power system. Computer simulation programs were developed under the same conditions but with various working fluids for a closed system, regeneration system, open system, Kalina system, and hybrid system. The results showed that the regeneration system using R125 showed a 0.17 to 1.56% increase in system efficiency. Moreover, the system can generate electricity when the difference in temperature between the warm and cold seawater inlet temperatures is greater than 15°C. In addition, the system efficiency of OTEC power plants using the condenser effluent from a nuclear power plant instead of surface water was increased by approximately 2%.

Keywords. OTEC; Regenerative system; Condenser effluent; Deep seawater; Surface seawater

© 2009 Copyright WSSET

Free to read, download, print and share, unaltered and for non-commercial purposes, provided the authors, the paper and the proceedings are credited. Any other use, including commercial use or adaptation, needs written permission: write to [email protected].

← SET Proceedings