Skip to content
Caravel Press

Conference paper

Thermal Performance Evaluation of Actual Multistory Type Double Skin Facade with Respect to Solar Radiation

, , ,

1Korea Institute of Energy Research, Daejeon 305-343, Republic of Korea

Published
4 September 2011
Pages
1-7
Received
4 September 2011
DOI
10.65582/set.2011.310
Access
Open access, © 2011 Copyright WSSET
Download PDF7 pages · 445 KB

Abstract

In this research, long-term measurement of inside and surface temperature of DSF is implemented and analyzed on the thermal performance of the system to provide validation data in the future researches. Interior air temperature rises while it go through double skin system and this is enforced by the amount of solar radiation. However, the temperature at fourth and fifth floor is almost similar due to air flow hindrance by small outlet area. The surface temperatures at the inside of outer glazing, inner glazing, and exterior wall show that double skin system is beneficial at heating season by raising surface temperatures regardless of solar radiation amount. Currently, the building is receiving additional high summer cooling load especially at 4th and 5th floor by staggered hot air at the top of the double skin system.

Keywords. Double Skin Façade; Solar radiation; Intermediate Space

© 2011 Copyright WSSET

Free to read, download, print and share, unaltered and for non-commercial purposes, provided the authors, the paper and the proceedings are credited. Any other use, including commercial use or adaptation, needs written permission: write to [email protected].