Energy and Exergy Analysis of a Trigeneration Facility with Natural Gas Engine

, , ,

1Department of Mechanical and Manufacturing Engineering, Engineering Faculty, Bilecik University, Bilecik, Turkey

2First Air Supply and Maintenances Center, TUAF, Eskisehir, Turkey

3Department of Mechanical Engineering, Engineering and Architecture Faculty, Eskisehir Osmangazi University, Eskisehir, Turkey

Published
2 September 2012
Pages
716-727
Received
2 September 2012
DOI
10.65582/set.2012.072
Access
Open access, © 2012 Copyright WSSET
Download PDF12 pages · 351 KB

Abstract

Natural gas engine (Wartsila 18VSG) having meanly 5993 kW electrical power output and used in a Trigeneration system located in Ankara was analyzed in terms of energy and exergy. Analysis, which is used actual data, was made to natural gas engine, heat recovery boiler and absorption chiller, while trigeneration system on full load operation conditions. Energy loss, energy efficiency, exergy destruction and exergy efficiencies of the trigeneration system was calculated. The energy and exergy efficiencies of system were determined as 64 % and 39 % respectively. FESR (fuel energy saving ratio) and FESxR (fuel exergy saving ratio) were calculated as % 27, % 28 respectively for Trigeneration facility.