Single Pass Solar Air Heater Without Absorber

,

1Mechanical Engineering Department, Eastern Mediterranean University, Famagusta, North Cyprus, Turkey

Published
2 September 2012
Pages
736-742
Received
2 September 2012
DOI
10.65582/set.2012.074
Access
Open access, © 2012 Copyright WSSET
Download PDF7 pages · 342 KB

Abstract

The single pass solar air heater is constructed and tested for thermal efficiency at a geographic location of Cyprus in the city of Famagusta. The length and the width of the collector are 150cm and 100cm respectively. The distance between the cover glass, 0.4cm in thickness, and the bottom of the collector, is 3 cm. The absorber plate was replaced by fourteen steel wire mesh layers, 0.2 × 0.2 cm in cross section opening, and they were fixed in the duct parallel to the glazing. The distance between each set of wire mesh layers is 0.5cm to reduce the pressure drop. The wire mesh layers were painted with black before installing them into the collector. The obtained results show that as the mass flow rate increases, the efficiency of the system will also increase. The temperature difference (∆T) between the inlet and outlet air through the system increases as the mass flow rate decreases. The maximum ∆T (45.8 °C) is achieved at the flow rate of 0.011 kg/s. The range of the mass flow rate used in this work is between 0.011 and 0.04 kg/s. It is also found that the maximum efficiency obtained for the single pass air collector is 53.01 % for the mass flow rate of 0.04 kg/s.

© 2012 Copyright WSSET

Free to read, download, print and share, unaltered and for non-commercial purposes, provided the authors, the paper and the proceedings are credited. Any other use, including commercial use or adaptation, needs written permission: write to [email protected].

← SET Proceedings