Numerical analysis of the humidity buffering potential of various hygrothermal coatings under extreme moisture overloading scenarios

1Division of Infrastructure, Geomatics and Architecture, Faculty of Engineering, University of Nottingham, University Park, Nottingham, NG7 2RD, UK

Published
6 July 2016
Pages
129-137
Received
6 July 2016
DOI
10.65582/set.2015.101
Access
Open access, © 2015 Copyright WSSET
Download PDF9 pages · 802 KB

Abstract

Within a closed environment, (e.g. building, car, aircraft) that is hygrically isolated from the exterior climate, one approach that can help reduce the energy required for indoor climate control whilst increasing comfort levels for occupants is to use hygrothermal coatings on top of existing materials. These coatings can re-introduce hygric buffering within the isolated envelope that was lost due to application of retrofitted internal finishes (i.e. – insulation, vapour barriers, paint etc.). The aim of this paper was to perform a parametric analysis using hygrothermal numerical software (WUFI Plus v2.1.1.73) of the humidity buffering potential of various hygrothermal coatings applied to a nominal enclosed indoor environment under extreme moisture loading scenarios and air exchange rates. Three coatings were compared: gypsum plaster, spruce timber and a ‘super absorbent’ desiccant under four building envelope scenarios. The location was chosen as Nottingham, UK and an external climate file was generated to sinusoidally fluctuate exterior relative humidity (RHext) about a median (50%) at constant temperature (T = 23 ºC) for a single peak to peak cycle period of t = 24h. Two sets of increased moisture profiles were applied to the model in order to represent 16 ‘Active Adults’ present in either the morning or evening for a period of t = 4 h. The analysis showed that there was minimal reduction of minimum indoor (RHint) levels when using traditional building materials as interior finishes (i.e. spruce and gypsum), indicating the greater influence of the external environment, RHext on the interior environment as the air exchange rate increased. In contrast, when utilising the super-adsorbent materials, RHint levels remained within the ASHRAE limits (i.e. 40% ≤ RHint ≤ 70% and T = 23 ºC) under both morning and evening overloading schedules and across the full range of air exchange rates.

Keywords. Humidity Buffering; Comfort; WUFI; Super-adsorbent

© 2015 Copyright WSSET

Free to read, download, print and share, unaltered and for non-commercial purposes, provided the authors, the paper and the proceedings are credited. Any other use, including commercial use or adaptation, needs written permission: write to [email protected].

← SET Proceedings