Skip to content
Caravel Press

Conference paper

Performance analysis of a solid desiccant enhanced indirect evaporative cooling system

, ,

1Clean Innovation Technology Group, Korea Institute of Industrial Technology (KITECH),102 Jejudaehak-ro, Jeju Special Self-Governing Province, 63243 South Korea

2Biological and Environmental Science and Engineering Division, King Abdullah University of Science & Technology, Thuwal, 23900 Kingdom of Saudi Arabia

3Department of Nuclear and Energy Engineering, Jeju National University,102 Jejudaehak-ro, Jeju Special Self-Governing Province, 63243 South Korea

Published
10 February 2020
Pages
181-187
Received
10 February 2020
DOI
10.65582/set.2019.079
Access
Open access, © 2019 Copyright WSSET
Download PDF7 pages · 773 KB

Abstract

This study proposes a disruptive cooling technology that thermodynamically hybridises two different cooling devices namely, a solid desiccant dehumidifier (SDD) and an indirect evaporative cooler (IEC) in order to enhance the performance IEC for all-weather conditions. Unlike conventional rotary desiccant wheels, the solid desiccant dehumidifier incorporates with desiccant coated heat exchangers to improve moisture removal capacity of desiccant by cooling the adsorption heat of desiccant. The indirect evaporative cooler operates based on M-cycle, which creates sensible cooling effect without the change of moisture level. In the proposed cooling system, the sensible and latent of the air are to be de-coupled. The latent cooling load, which is 25 to 45% of the total cooling load in most weather, is first removed by adsorption of vapour using desiccant coated heat exchangers. The saturated adsorbent is then regenerated by using either low-temperature waste heat from industry and/or renewable energy such as solar energy and geothermal energy. With the de-coupling of the latent cooling, the remaining sensible cooling load is removed by the indirect evaporative process where water is evaporated by the purged air from the dry channel, flowing over water-film surfaces in the wet channel. A numerical simulation has been carried out so as to compare the performance of the cooling system in terms of cooling capacity and dew-point effectiveness with a single IEC. The experimental data obtained from the previous research was employed as the inlet conditions for IEC. Key results revealed that the proposed SDDIECproduced higher cooling capacity, as well as higher dew-point effectiveness under the same operating conditions.

Keywords. desiccant coated heat exchanger; indirect evaporative cooler; de-coupled cooling load; dew-point effectiveness; coefficient of performance

© 2019 Copyright WSSET

Free to read, download, print and share, unaltered and for non-commercial purposes, provided the authors, the paper and the proceedings are credited. Any other use, including commercial use or adaptation, needs written permission: write to [email protected].