Coriolis flowmeters are used when direct mass flow rates and density measurements are desired. This phenomenon is achieved by directing the passing fluid to a U-shaped tube, resulting in Coriolis force. With the help of the Coriolis force, a phase shift occurs between two sides of the measurement tube. Furthermore, a flow separator is used in order to increase measurement accuracy with two identical measurement tubes. Coriolis flowmeters have relatively high pressure drop values as compared to other flowmeter types, and this is an issue that needs to be addressed. In this study, pressure drop minimisation of a Coriolis-type flowmeter was performed. Firstly, a 3D numerical study was carried out in order to obtain pressure drop, and the numerical study was validated with experiments. Accordingly, an orthogonal optimization study was performed with three independent variables: separation angle, upper curvature radius of the measurement tube, and lower curvature radius of the measurement tube. The pipe length was kept constant and the influence of the mentioned variables were investigated simultaneously. Computational fluid dynamics (CFD) studies were carried out for proposed design points for a constant flow rate value. Finally, the variation in pressure drop with respect to varying flow rate was obtained for the optimized measurement tube. During numerical simulations, shear stress transport (SST) turbulence model was used.
Basse, N. T. (2014). A review of the theory of Coriolis flowmeter measurement errors due to entrained particles. Flow Measurement and Instrumentation, 37, 107-118.
Basse, N. T. (2016). Coriolis flowmeter damping for two-phase flow due to decoupling. Flow Measurement and Instrumentation, 52, 40-52.
Bentley, J. P. (2005). “Principles of Measurement Systems” (4th ed.). Pearson.
Bobovnik, G., Kutin, J., & Bajsić, I. (2004). The effect of flow conditions on the sensitivity of the Coriolis flowmeter. Flow Measurement and Instrumentation, 15(2), 69-76.
Cascetta, F. (1996). “Effect of fluid pressure on Coriolis mass flowmeter’s performance”, ISA Transactions, 35(4), 365–370.
Clark, C., Zamora, M., Cheesewright, R., & Henry, M. (2006). The dynamic performance of a new ultra-fast response Coriolis flow meter. Flow Measurement and Instrumentation, 17(6), 391-398.
Enz, S. (2010). Effect of asymmetric actuator and detector position on Coriolis flowmeter and measured phase shift. Flow Measurement and Instrumentation, 21(4), 497-503.
Hemp, J., & Kutin, J. (2006). Theory of errors in Coriolis flowmeter readings due to compressibility of the fluid being metered. Flow measurement and Instrumentation, 17(6), 359-369.
Hu, Y. C., Chen, Z. Y., & Chang, P. Z. (2021). “Fluid–Structure Coupling Effects in a Dual U-Tube Coriolis Mass Flow Meter”, Sensors, 21(3), 982.
Kumar, V., & Anklin, M. (2011). “Numerical simulations of Coriolis flow meters for low Reynolds number flows”, MAPAN, 26(3), 225–235.
Kutin, J., & Bajsić, I. (1999). “Characteristics of The Shell Type Coriolis Flowmeter”, Journal of Sound and Vibration, 228(2), 227–242.
Methods and formulas for Analyze Taguchi Design - Minitab. (n.d.). Retrieved from https://bit.ly/3yk5MUC
Rongmo, L., Dalson, G. A., & Cheong, K. B. (2018). “Experimental Measurement and CFD Simulation for Characterization of Coriolis Flowmeter Performance”, Journal of Physics: Conference Series, 1065, 092005.
Shanmugavalli, M., Umapathy, M., & Uma, G. (2010). Smart Coriolis mass flowmeter. Measurement, 43(4), 549-555.
Sultan, G. (1992). “Single straight-tube Coriolis mass flowmeter”, Flow Measurement and Instrumentation, 3(4), 241–246.
Wang, T., & Hussain, Y. (2010). Pressure effects on Coriolis mass flowmeters. Flow Measurement and Instrumentation, 21(4), 504-510.
Xing, L., Geng, Y., Hua, C., Zhu, H., Rieder, A., Drahm, W., & Bezdek, M. (2014). A combination method for metering gas–liquid two-phase flows of low liquid loading applying ultrasonic and Coriolis flowmeters. Flow Measurement and Instrumentation, 37, 135-143.
How to cite this article
Bozkurt, A.E., Dönmez, A.H., Mutlu, Y. and Kavurmacioğlu, L. (2022). 'Pressure drop optimization of a Coriolis-type flowmeter based on orthogonal method'. SET Proceedings, 19(2), pp. 231-240. https://doi.org/10.65582/set.2022.071