Energy-efficient cooling and ventilation is critical to reduce carbon emissions and cut energy bills, especially for traditional data centres, which use around 20% of global data centre energy demand. This paper presents the latest deployment demonstration projects using the super performance dew point cooling technology in real life data centre businesses. With over 15-years’ continuous endeavour, the researchers at the University of Hull have developed a specialised indirect evaporative cooler which has achieved a COP of 52.5 in the laboratory setting. With the super performance cooler tested in laboratory in 2021, the authors have applied and demonstrated the technology in two real-life data centres to meet the peak cooling demand of up to 100 kW. This was the first project which applied the technology to real-world business in a relatively large scale, which has generated surprising results that were highly valuable and interesting to share with peers working in the field of low carbon technologies, especially the sustainable heating and cooling area. This paper covers the latest findings from the project, including the innovations, the project, the demonstration system, energy performance, real life data and results, as well as the project learnings.
Keywords. indirect evaporative cooling; real life demonstration; energy performance; data centre cooling
References
ASHRAE 2015. ANSI/ASHRAE Standard 143-2015 Method of Test For Rating Indirect Evaporative Coolers.
ASHRAE 2016. Data Center Power Equipment Thermal Guidelines and Best Practices.
European Commission 2020. Green and Digital: study shows technical and policy options to limit surge in energy consumption for cloud and data centres. Available at: https://ec.europa.eu/info/news/green-and-digital-study-shows-technical-and-policy-options-limit-surge-energy-consumption-cloud-and-data-centres-2020-nov-09_en.
Glanville, P., Kozlov, A. and Maisotsenko, V. [no date]. Dew Point Evaporative Cooling: Technology Review and Fundamentals.
GOV.UK 2021. Industrial Energy Efficiency Accelerator: projects selected for Phase 2. Available at: Industrial Energy Efficiency Accelerator: projects selected for Phase 2.
IEA 2021. Global data centre energy demand by data centre type, 2010-2022. Available at: https://www.iea.org/data-and-statistics/charts/global-data-centre-energy-demand-by-data-centre-type-2010-2022.
Xu, P., Ma, X., Diallo, T.M.O., Zhao, X., Fancey, K., Li, D. and Chen, H. 2016. Numerical investigation of the energy performance of a guideless irregular heat and mass exchanger with corrugated heat transfer surface for dew point cooling. Energy 109, pp. 803–817. Available at: http://dx.doi.org/10.1016/j.energy.2016.05.062.
Xu, P., Ma, X., Zhao, X. and Fancey, K. 2017. Experimental investigation of a super performance dew point air cooler. Applied Energy 203, pp. 761–777. Available at: http://dx.doi.org/10.1016/j.apenergy.2017.06.095.
How to cite this article
Zeng, C., Zhu, Z., Li, Y., Wang, Z., Ma, X. and Zhao, X. (2022). 'The deployment and demonstration of a super performance indirect evaporative cooler in real-life data centres'. SET Proceedings, 19(3), pp. 55-63. https://doi.org/10.65582/set.2022.097