Heating buildings is a pressing issue in the UK given the UK's commitment to achieving net zero emissions targets. To solve this problem, a building strategy to effectively reduce energy consumption by simulating and modifying window size parameters is developed. This study mainly uses computer simulation experiments to evaluate the impact of optimizing window size on energy consumption during building renovation. For this purpose, a detached building located in Nottingham, UK was chosen as a model. The results of the study show that the south side of the building has the most significant impact on energy consumption. Therefore, by increasing the size of the south-facing windows, the overall energy consumption of the building can be significantly reduced. The study showed that the ideal window size increase was 1.6 times the original size, resulting in a window-to-wall ratio of 7.86% compared to 4.91% of the original size. When the technology of changing the window size is combined with multi-layer glass windows filled with xenon and Low-E vacuum windows, the building energy consumption can be better reduced, which can reduce the total energy consumption by 2.65% and 4.14% respectively. On the contrary, the study highlights that the presence of north-facing windows has a negative impact on the building's energy consumption. The findings have important implications for window reconstruction in British buildings. The research methodology and results can provide a valuable reference for architects and engineers seeking to optimize window design to minimize energy consumption in various types of residential buildings. By applying a similar window optimization approach, it is possible to determine optimal values for reducing energy consumption in different types of residential structures. The research demonstrates the potential to improve the energy efficiency of buildings and contribute to the UK's wider efforts to achieve net zero targets. Implementing these findings in building renovations could pave the way for a more sustainable future and promote energy awareness in the building industry.
Keywords. Net Zero Target; Building Retrofit; Window Size; Energy Simulation; Energy Consumption
References
aguilar, J. O., Xamán, J., Olazo-Gómez, Y., Hernández-López, I., Becerra, G. & Jaramillo, O. A. 2017. Thermal performance of a room with a double glazing window using glazing available in Mexican market. Applied Thermal Engineering, 119, 505-515.
Albatayneh, A., Atieh, H., Jaradat, M., Al-Omary, M., Zaquot, M., Juaidi, A., Abdallah, R. & Manzano-Agugliaro, F. 2021. The Impact of Modern Artificial Lighting on the Optimum Window-to-Wall Ratio of Residential Buildings in Jordan. Applied Sciences, 11.
Arıcı, M. & KARABAY, H. 2010. Determination of optimum thickness of double-glazed windows for the climatic regions of Turkey. Energy and Buildings, 42, 1773-1778.
Budhiyanto, A. 2017. The Effect of the Window-to-Wall Ratio on Cooling Energy Usage and Comfort Temperature. DIMENSI (Journal of Architecture and Built Environment), 44.
Caggiano, A., Junlin, Z. & Longwei, Z. 2021. Multi objective optimization of window to wall ratio of University Gymnasium in severe cold area by coupling natural lighting and energy consumption. E3S Web of Conferences, 293.
Chiesa, G., Acquaviva, A., Grosso, M., Bottaccioli, L., Floridia, M., Pristeri, E. & Sanna, E. 2019. Parametric Optimization of Window-to-Wall Ratio for Passive Buildings Adopting A Scripting Methodology to Dynamic-Energy Simulation. Sustainability, 11.
Dewi, O. C., Rahmasari, K., Hanjani, T. A., Ismoyo, A. D. & Dugar, A. M. 2022. Window-to-Wall Ratio as a Mode of Daylight Optimization for an Educational Building with Opaque Double-Skin Façade. Journal of Sustainable Architecture and Civil Engineering, 30, 142-152.
Fathi, S. & Kavoosi, A. 2021. Optimal Window to Wall Ratio Ranges of Photovoltachromic Windows in High-Rise Office Buildings of Iran. Journal of Daylighting, 8, 134-148.
Goia, F. 2016. Search for the optimal window-to-wall ratio in office buildings in different European climates and the implications on total energy saving potential. Solar Energy, 132, 467-492.
Lahmar, I., Cannavale, A., Martellotta, F. & Zemmouri, N. 2022. The Impact of Building Orientation and Window-to-Wall Ratio on the Performance of Electrochromic Glazing in Hot Arid Climates: A Parametric Assessment. Buildings, 12.
Li, A., Cheng, L., Tao, Q., Tang, Y., Olofsson, T. & Kosonen, R. 2022. Optimized design and energy consumption simulation of window-wall ratio in Yanqui Library, Jimei University. E3S Web of Conferences, 356.
Li, J., Zheng, B., Chen, X., Zhou, Y., Rao, J. & Bedra, K. B. 2020. Research on Annual Thermal Environment of Non-Hvac Building Regulated by Window-to-Wall Ratio in a Chinese City (Chenzhou). Sustainability, 12.
Liu, C., Wu, Y., Li, D., Zhou, Y., Wang, Z. & Liu, X. 2017. Effect of PCM thickness and melting temperature on thermal performance of double glazing units. Journal of Building Engineering, 11, 87-95.
Liu, H., Zhang, Z., Ma, X., Lu, W., Li, D. & Kojima, S. 2021. Optimization Analysis of the Residential Window-to-Wall Ratio Based on Numerical Calculation of Energy Consumption in the Hot-Summer and Cold-Winter Zone of China. Sustainability, 13.
Ma, P., Wang, L.-S. & Guo, N. 2015. Maximum window-to-wall ratio of a thermally autonomous building as a function of envelope U -value and ambient temperature amplitude. Applied Energy, 146, 84-91.
Shaeri, J., Habibi, A., Yaghoubi, M. & Chokhachian, A. 2019. The Optimum Window-to-Wall Ratio in Office Buildings for Hot‒Humid, Hot‒Dry, and Cold Climates in Iran. Environments, 6.
Tummala, S., Kumar, D. R. V., N, S. K., K, N., K, S. R. R., E, V. K., Kosaraju, S., Bobba, P. & Singh, S. 2020. Spatial Day Light Autonomy and Energy Analysis of a Residential Building for Different Climatic Conditions and Window-to-Wall Ratios. E3S Web of Conferences, 184.
Xue, P., Li, Q., Xie, J., Zhao, M. & Liu, J. 2019. Optimization of window-to-wall ratio with sunshades in China low latitude region considering daylighting and energy saving requirements. Applied Energy, 233-234, 62-70.
Yang, Q., Liu, M., Shu, C., Mmereki, D., Uzzal Hossain, M. & Zhan, X. 2015. Impact Analysis of Window-Wall Ratio on Heating and Cooling Energy Consumption of Residential Buildings in Hot Summer and Cold Winter Zone in China. Journal of Engineering, 2015, 1-17.
Yu, Z., Zhang, W. L. & Fang, T. Y. 2013. Impact of Building Orientation and Window-Wall Ratio on the Office Building Energy Consumption. Applied Mechanics and Materials, 409-410, 606-611.
Zhou, Z. H., Hu, S. & Du, T. 2012. Study on Determination of Best Window-Wall Ratio of Office Building in Cold Area. Applied Mechanics and Materials, 260-261, 209-216.
How to cite this article
Zhang, Y. and Omer, S. (2023). 'Building retrofit- an active influence on the residential building's energy consumption by changing the size of the windows'. SET Proceedings, 20(3), pp. 110-120. https://doi.org/10.65582/set.2023.105