The recent pandemic has accentuated the importance of clean indoor air and the risks associated with the airborne spread of pathogens. Outdoor meteorology and building configuration can spread pollutants and pathogens between different indoor units, deteriorating the air quality in the process. While previous studies have mainly focused on inter-unit pollutant crossflow in highrise buildings and isolated scenarios, the role of street canyon configurations in urban areas remains crucial for understanding ventilation characteristics and limiting the spread of contaminants. This research aims to evaluate the wind-driven transmission characteristics of pollutants between adjacent indoor units situated along a street canyon. By employing a numerical model, validated against experimental data, the study compares the impacts of five building ventilation strategies, each representing specific window opening combinations on the two buildings. Based on the environmental conditions set for the study, the results demonstrate that inter-unit transmission is reliant on both, the air change rate and the unit’s specific location. By increasing the air change rate, cross-transmission decreases, offering an effective strategy to limit contaminants. However, units placed at the centre of the street canyon are more susceptible to contamination, requiring additional precautions for their occupants. Notably, the spatial arrangement of apartments (or units) within the canyon influences pollution diffusion along the street. Apartments at the canyon's edges may not directly contaminate units further down the street, but they still have a subtle influence, contributing small doses of pollutants. This study advances our understanding of inter-unit pollutant transmission in urban street canyons. Armed with these insights, residents can make informed decisions about adopting tailored ventilation strategies based on their apartment's location, proactively safeguarding their health. By employing the right ventilation strategies, residents can effectively minimize exposure to airborne pollutants, ensuring a healthier living environment in densely populated urban areas.
Keywords. Pollutant transmission; street canyon; inter-unit; CFD; natural ventilation
References
Ai, Z. T., & Mak, C. M. (2018). Wind-induced single-sided natural ventilation in buildings near a long street canyon: CFD evaluation of street configuration and envelope design. Journal of Wind Engineering and Industrial Aerodynamics, 172, 96–106. https://doi.org/10.1016/J.JWEIA.2017.10.024
Ai, Z. T., Mak, C. M., & Niu, J. L. (2013). Numerical investigation of wind-induced airflow and interunit dispersion characteristics in multistory residential buildings. Indoor Air, 23(5), 417–429. https://doi.org/10.1111/ina.12041
Ansys® Fluent (Release 18.1). (n.d.).
Borck, R., & Schrauth, P. (2021). Population density and urban air quality. Regional Science and Urban Economics, 86, 103596. https://doi.org/10.1016/J.REGSCIURBECO.2020.103596
Buccolieri, R., Gromke, C., di Sabatino, S., & Ruck, B. (2009). Aerodynamic effects of trees on pollutant concentration in street canyons [Article]. Science of The Total Environment, 407(19), 5247–5256. https://doi.org/10.1016/j.scitotenv.2009.06.016
Chen, F., Yu, S. C. M., & Lai, A. C. K. (2006). Modeling particle distribution and deposition in indoor environments with a new drift-flux model. Atmospheric Environment, 40(2), 357–367. https://doi.org/10.1016/J.ATMOSENV.2005.09.044
Cui, D. J., Mak, C. M., Kwok, K. C. S., & Ai, Z. T. (2016). CFD simulation of the effect of an upstream building on the inter-unit dispersion in a multi-story building in two wind directions. Journal of Wind Engineering and Industrial Aerodynamics, 150, 31–41. https://doi.org/10.1016/j.jweia.2016.01.007
Cui, P. Y., Zhang, Y., Chen, W. Q., Zhang, J. H., Luo, Y., & Huang, Y. D. (2021). Wind-tunnel studies on the characteristics of indoor/outdoor airflow and pollutant exchange in a building cluster. Journal of Wind Engineering and Industrial Aerodynamics, 214, 104645. https://doi.org/10.1016/J.JWEIA.2021.104645
Dai, Y. W., Mak, C. M., & Ai, Z. T. (2017). Computational fluid dynamics simulation of wind-driven inter-unit dispersion around multi-storey buildings: Upstream building effect. Https://Doi.Org/10.1177/1420326X17745943, 28(2), 217–234. https://doi.org/10.1177/1420326X17745943
Franke, J., Hirsch, C., Jensen, G., Krüs, H. W., Miles, S. D., Schatzmann, M., Westbury, P. S., Wisse, J. A., & Wright, N. (2004). Recommendations on the use of CFD in wind engineering. Proceedings of the International Conference on Urban Wind Engineering and Building Aerodynamics, C.1.1–C1.11.
Ganasegeran, K., Jamil, M. F. A., Ch’ng, A. S. H., Looi, I., & Peariasamy, K. M. (2021). Influence of population density for covid-19 spread in malaysia: An ecological study. International Journal of Environmental Research and Public Health, 18(18). https://doi.org/10.3390/IJERPH18189866/S1
Gromke, C., & Blocken, B. (2015). Influence of avenue-trees on air quality at the urban neighborhood scale. Part II: Traffic pollutant concentrations at pedestrian level. Environmental Pollution, 196, 176–184. https://doi.org/10.1016/J.ENVPOL.2014.10.015
Gromke, C., Buccolieri, R., Di Sabatino, S., & Ruck, B. (2008). Dispersion study in a street canyon with tree planting by means of wind tunnel and numerical investigations - Evaluation of CFD data with experimental data. Atmospheric Environment, 42(37), 8640–8650. https://doi.org/10.1016/j.atmosenv.2008.08.019
Karlsruhe Institute of Technology. (2008). CODASC (2008) Concentration Data of Street Canyons. Laboratory of Building- and Environmental Aerodynamics. https://www.windforschung.de/CODASC.htm
Kastner-Klein, P., & Plate, E. J. (1999). Wind-tunnel study of concentration fields in street canyons. Atmospheric Environment, 33(24–25), 3973–3979. https://doi.org/10.1016/S1352-2310(99)00139-9
Mei, S. J., Luo, Z., Zhao, F. Y., & Wang, H. Q. (2019). Street canyon ventilation and airborne pollutant dispersion: 2-D versus 3-D CFD simulations. Sustainable Cities and Society, 50, 101700. https://doi.org/10.1016/j.scs.2019.101700
Mohammadi, M., & Calautit, J. (2021). Impact of Ventilation Strategy on the Transmission of Outdoor Pollutants into Indoor Environment Using CFD. Sustainability 2021, Vol. 13, Page 10343, 13(18), 10343. https://doi.org/10.3390/SU131810343
Morakinyo, T. E., & Lam, Y. F. (2016). Study of traffic-related pollutant removal from street canyon with trees: dispersion and deposition perspective. Environmental Science and Pollution Research, 23(21), 21652–21668. https://doi.org/10.1007/s11356-016-7322-9
Mu, D., Gao, N., & Zhu, T. (2016). Wind tunnel tests of inter-flat pollutant transmission characteristics in a rectangular multi-storey residential building, part A: Effect of wind direction. Building and Environment, 108, 159–170. https://doi.org/10.1016/j.buildenv.2016.08.032
Mu, D., Gao, N., & Zhu, T. (2018). CFD investigation on the effects of wind and thermal wall-flow on pollutant transmission in a high-rise building. Building and Environment, 137, 185–197. https://doi.org/10.1016/j.buildenv.2018.03.051
Mu, D., Shu, C., Gao, N., & Zhu, T. (2017). Wind tunnel tests of inter-flat pollutant transmission characteristics in a rectangular multi-storey residential building, part B: Effect of source location. Building and Environment, 114, 281–292. https://doi.org/10.1016/j.buildenv.2016.12.031
Peng, Y., Ma, X., Zhao, F., Liu, C., & Mei, S. (2017). Wind driven natural ventilation and pollutant dispersion in the dense street canyons: Wind Opening Percentage and its effects. Procedia Engineering, 205, 415–422. https://doi.org/10.1016/j.proeng.2017.10.392
Riley, R. L. (1974). Airborne infection. The American Journal of Medicine, 57(3), 466–475. https://doi.org/10.1016/0002-9343(74)90140-5
Salim, S. M. (2011). Computational study of wind flow and pollutant dispersion near tree canopies [University of Nottingham]. http://eprints.nottingham.ac.uk/12077/1/Thesis_-_Salim_M_Salim.pdf
Salim, S. M., Buccolieri, R., Chan, A., & Di Sabatino, S. (2011). Numerical simulation of atmospheric pollutant dispersion in an urban street canyon: Comparison between RANS and LES. Journal of Wind Engineering and Industrial Aerodynamics, 99(2–3), 103–113. https://doi.org/10.1016/j.jweia.2010.12.002
Tominaga, Y., Mochida, A., Yoshie, R., Kataoka, H., Nozu, T., Yoshikawa, M., & Shirasawa, T. (2008). AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings. Journal of Wind Engineering and Industrial Aerodynamics, 96(10–11), 1749–1761. https://doi.org/10.1016/J.JWEIA.2008.02.058
Tominaga, Y., & Stathopoulos, T. (2011). CFD modeling of pollution dispersion in a street canyon: Comparison between LES and RANS. Journal of Wind Engineering and Industrial Aerodynamics, 99(4), 340–348. https://doi.org/10.1016/J.JWEIA.2010.12.005
Wang, J., Huo, Q., Zhang, T., Wang, S., & Battaglia, F. (2020). Numerical investigation of gaseous pollutant cross-transmission for single-sided natural ventilation driven by buoyancy and wind. Building and Environment, 172, 106705. https://doi.org/10.1016/j.buildenv.2020.106705
Wang, J., Zhang, T., Wang, S., & Battaglia, F. (2017). Gaseous pollutant transmission through windows between vertical floors in a multistory building with natural ventilation. Energy and Buildings, 153, 325–340. https://doi.org/10.1016/j.enbuild.2017.08.025
Wang, Q., Sandberg, M., Lin, Y., Yin, S., & Hang, J. (2017). Impacts of Urban Layouts and Open Space on Urban Ventilation Evaluated by Concentration Decay Method. Atmosphere 2017, Vol. 8, Page 169, 8(9), 169. https://doi.org/10.3390/ATMOS8090169
Yang, F., Gao, Y., Zhong, K., & Kang, Y. (2016). Impacts of cross-ventilation on the air quality in street canyons with different building arrangements. Building and Environment, 104, 1–12. https://doi.org/10.1016/J.BUILDENV.2016.04.013
Yang, F., Kang, Y., Gao, Y., & Zhong, K. (2015). Numerical simulations of the effect of outdoor pollutants on indoor air quality of buildings next to a street canyon. Building and Environment, 87, 10–22. https://doi.org/10.1016/j.buildenv.2015.01.008
How to cite this article
Mohammadi, M. and Calautit, J. (2023). 'Inter-unit transmission of pollutants in naturally ventilated buildings adjoining a street canyon: a parametric study'. SET Proceedings, 20(3), pp. 137-147. https://doi.org/10.65582/set.2023.108