Urban underground space is an important natural resource, and making full use of this space is crucial for urban sustainable development. Vigorously developing underground cable tunnels is an effective strategy to meet the growing demand for power supply in cities. However, the thermal and humid environment in cable tunnels significantly impacts their operation, with condensation posing a major threat to electronic equipment and cables. To address this, a long-term field monitoring method was used to track the temperature and humidity of a cable tunnel in Shanghai for 10 months. The heat transfer mechanism within the tunnel was analyzed, and the temperature and humidity distribution within the tunnel body and the ventilation shaft equipment room were studied. The influence of the external environment on the internal conditions of the cable tunnel was also examined. The results show that temperature and humidity distribution in the cable tunnel is not uniform along its axial direction. Due to natural ventilation, the temperature near the air supply shaft is highly variable, while the temperature near the exhaust shaft is relatively stable at about 25.0°C. Influenced by external environmental changes and heat accumulation from the cables, both the air temperature and the wall temperature in the tunnel increase gradually, with the temperature variation range decreasing from the air supply shaft to the exhaust shaft. From June to August, the daytime outdoor air dew point temperature in Shanghai can reach 25°C. Since the wall temperature at the tunnel entrance is lower than the outdoor air dew point temperature, condensation occurs when outdoor air enters the tunnel. Therefore, air dehumidification should be implemented at the air supply shaft. Additionally, this paper explores methods for controlling humidity in cable tunnels. During transitional seasons, mechanical ventilation and dehumidification using fans can be employed, but special attention is needed for specific weather conditions.
Keywords. Urban Underground Space; Cable Tunnel; Thermal and Moisture Characteristics; Dew Point Temperature; Humidity Control
References
BRAGATTO, T. et al. ’A 3-D nonlinear thermal circuit model of underground MV power cables and their joints’, Electric Power Systems Research, 173: pp, 112-121.
GIGLIO, D.A. and DE,LEóN F.(2023) ’Dynamic Thermal Model for Different Size Trefoil Power Cables With Various Loads in Non-Forced-Ventilated Tunnels’, IEEE TRANSACTIONS ON POWER DELIVERY, 38(2), pp, 1286-96.
Han, J.et al.(2017) ’Temperature and Moisture Distributions of Long Tunnels and Analysis of Condensation on Tunnel Walls in Hot and Humid Areas’, Journal of the China Railway Society, 39(7), pp, 123-132.
Li, H.et al.(2017) ’Study on the Thermal Environment of Cable Operation in Urban Corridors’, Power System and Clean Energy, 33(7), pp. 85-89.
Luo, C.et al.(2019) ’Temperature Field Simulation and Ampacity Calculation of Multi-loop Cable Tunnel with Ventilation’, 2019 IEEE 4th Advanced Information Technology, Electronic and Automation Control Conference (IAEAC), F 20-22 Dec. 2019, 2019 [C].
Ni, L.et al.(2009) ’Thermal field analysis for 500 kV cable tunnels’, East China Electric Power, 37(11), pp. 1886-1890.
Sun, Q. et al.(2021) ’Thermal network modeling of tunnel cable considering circumferential heat transfer and tunnelcurvature ‘, Electric Power Systems Research,196: 107190.
Wang, J. et al.(2019) ‘Reduced-scale model study on cable heat dissipation and airflow distribution of power cabins’, Applied Thermal Engineering, 160: 114068.
Wang, M. et al.(2020) ‘Calculation of electrothermal coupling power flow for XLPE insulated cable-based distribution systems ‘, International Journal of Electrical Power & Energy Systems, 117: 105680.
Wang, X.et al.(2022), ’Piston-wind ventilation strategy for thermal environment improvement of heat-supply compartmentin utility tunnels’, Case Studies in Thermal Engineering, 30: 101790.
Zhang, H.et al.(2010) ’Simulation of Temperature Field and Ampacity of Underground Cable System Based on Finite Element Method’, High Voltage Apparatus, 46(02), pp, 42-45+51.
Zhu, H.et al.(2024) ’Heat-force characteristic analysis of tunnel serpentine laying cable’, Electric Power Systems Research, 230: 110236.
Zhu, X. and Lei, J. and Hu, P.(2011) ’Mechanisms and Countermeasures for Tunnel Damping and Slipping: Case Study on Baojiashan Tunnel’, Tunnel Construction, 31(06), pp, 690-692.
How to cite this article
Zhang, X., Wang, S., Zhang, Y., Wang, L., Wu, C., Tang, M. and Zang, J. (2024). 'Analysis of annual heat and moisture variation characteristics in cable tunnel and research on control method'. SET Proceedings, 21(4), pp. 12-21. https://doi.org/10.65582/set.2024.165