As the demand for sustainable energy solutions grows, photovoltaic windows (PV windows) have gained significant attention as an emerging building integrated photovoltaics (BIPV) technology. This is due to their dual potential in reducing building energy consumption and providing renewable energy sources. This study aims to propose an analytical solution for the energy assessment model of semi-transparent photovoltaic insulating glass units (STPV-IGU) by simplifying the thermal balance equation nodes. The efficacy of the proposed model was validated through comparison with experimental data, demonstrating a high degree of congruence. Additionally, an equivalent electrical method is employed, which uniformly converts non-electric forms of energy into electrical energy according to possible conversion coefficients. Taking Shanghai as an example, a comparative analysis of the annual energy performance of the south-facing window system for STPV-IGU and double-glazed insulating glass units (DS-IGU) was conducted. The results show that the annual net electricity consumption of STPV-IGU is -11.5 W/m², while that of DS-IGU is 22.3 W/m², indicating that STPV-IGU has substantial energy-saving potential.
Keywords. Semi-Transparent Photovoltaic Insulating Glass Units; Model Simplification; Equivalent Electrical Method; Energy Performance
References
Athienitis A K, Barone G, Buonomano A, et al, 2018.Assessing active and passive effects of façade building integrated photovoltaics/thermal systems: Dynamic modelling and simulation [J]. Applied Energy, 209:355-82
Coakley D, Raftery P, 2014. Keane M. A review of methods to match building energy simulation models to measured data[J]. Renewable and Sustainable Energy Reviews, 37: 123-41
Ding H, Yu G, 2022.Development of a simplified resistance-capacity network thermal model for semi-transparent photovoltaic insulating glass unit [J]. Solar Energy, 245: 165-82
Duffie J A, Beckman W A, 2013.Solar Engineering of Thermal Processes [M]. Edition F. America: A wiley-interscience.
Goia F, Perino M, Haase M, 2012.A numerical model to evaluate the thermal behaviour of PCM glazing system configurations [J]. Energy and Buildings, 54: 141-53
Guideline A J A g, 2014.Measurement of energy, demand, and water savings [J],4: 1-150
Guyot D, Giraud F, Simon F, et al, 2020. Building energy model calibration: A detailed case study using sub-hourlymeasured data [J]. Energy and Buildings, 223
Liu Z, Liu Y, He B-J, et al, 2019.Application and suitability analysis of the key technologies in nearly zero energy buildings in China [J]. Renewable and Sustainable Energy Reviews, 101:329-45
Khalvati F, Omidvar A, 2019. Summer study on thermal performance of an exhausting airflow window in evaporatively - cooled buildings [J]. Applied Thermal Engineering,153: 147-58
Liao W, Xu S, 2015. Energy performance comparison among see-through amorphous-silicon PV (photovoltaic) glazings and traditional glazings under different architectural conditions in China [J]. Energy, 83: 267-75
Peng C, Huang Y, Wu Z, 2011.Building-integrated photovoltaics (BIPV) in architectural design in China [J]. Energy and Buildings , 43(12): 3592-8
Rathore M M, Kapuno R, 2010.Engineering heat transfer [M]. Jones & Bartlett Publishers
Swinbank W C J Q J o t R M S, 1963.Long-wave radiation from clear skies [J], 89(381): 339-48
Wang C, Uddin M M, Ji J, et al, 2021.The performance analysis of a double-skin ventilated window integrated with CdTe cells in typical climate regions [J]. Energy and Buildings, 241
Yu G, Yang H, Luo D, et al,2021. A review on developments and researches of building integrated photovoltaic (BIPV) windows and shading blinds [J]. Renewable and Sustainable Energy Reviews, 149
Zhang Q, Joe H, 2004.China Building Standard Meteorological Database [M]. China Building Standard Meteorological Database.
How to cite this article
Yu, G., Chen, M. and Chen, Y. (2024). 'Simplified solution and comprehensive performance analysis of dynamic models for semi-transparent photovoltaic insulating glass'. SET Proceedings, 21(4), pp. 22-31. https://doi.org/10.65582/set.2024.166