Conference paper
Experimental study on the thermal and electrical performance of solar PV vacuum glazing skylights
, ,
1Renewable Energy Research Group (RERG), Department of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China
* Correspondence: Hongxing Yang, [email protected]
History
Received
22 Jun 2026
Revised
7 Jul 2026
Accepted
16 Jul 2026
Published
23 Nov 2026
Received to published in 154 days·Pages 293-298
Abstract
Keywords. BIPV (building-integrated photovoltaic); Vacuum photovoltaics (PV) glass; Power generation; Energy saving
Nomenclature
| Abbreviation | |
|---|---|
| BIPV | building-integrated photovoltaic |
| PV | photovoltaic |
| SPVGS | solar photovoltaic vacuum glazing skylight |
| VGS | vacuum glazing skylight |
| Low-E | low emittance |
| STPV | semi-transparent photovoltaic |
1. Introduction
In Hong Kong, buildings account for approximately 90% of total electricity consumption and 60% of associated carbon emissions. Consequently, reducing building energy consumption is both an urgent and essential measure for achieving Hong Kong's carbon neutrality target by 2050 (GovHK 2025).
Skylights are widely adopted in commercial buildings, including shopping malls, airport terminals, and railway stations, to enhance natural daylighting and aesthetic appeal. While skylights can reduce lighting energy demand by providing natural daylight, the transmitted solar irradiance leads to increased indoor heat gains, thereby elevating cooling loads (Pu et al. 2025). Moreover, high visible light transmittance (VLT) can cause visual discomfort. For instance, increasing the VLT from 0.4 to 0.8 raises the glare potential from 1.5%–7.2% to 2%–16.7% (El-Abd et al. 2018). To address this issue, an effective solution was provided by the semi-transparent photovoltaic (STPV) skylight.
Semi-transparent photovoltaic (STPV) skylights have emerged as an effective solution to these challenges. STPV skylights not only harvest solar energy to generate electricity for building operations but also provide inherent shading that reduces indoor heat gains. Compared with conventional skylights, STPV skylights achieve an energy-saving ratio exceeding 24% in Kunming and Xiamen, China (Fan et al. 2022). However, their relatively high thermal transmittance (U-value), ranging from 1.812–5.804 W/(m2·K) (Fan et al. 2022), results in poor thermal insulation and significant heat losses through the skylight.
To overcome these limitations, this study proposes a cadmium telluride (CdTe)-based solar photovoltaic vacuum glazing skylight (SPVGS). The CdTe PV glazing is laminated onto vacuum glazing using a polyvinyl butyral (PVB) interlayer. The vacuum gap, maintained at a pressure below 0.1 Pa, suppresses gaseous heat transfer, while a low-emissivity (low-E) coating applied to the glazing surface minimizes radiative heat transfer (Zhou et al. 2024). To evaluate the energy-saving potential of the SPVGS, an outdoor experiment was conducted in Hong Kong to examine its thermal and energy performance. For comparison, a vacuum glazing skylight (VGS) was also tested to benchmark its thermal insulation performance against that of the SPVGS. Given Hong Kong's abundant solar resources and hot climate, this innovative skylight design has strong potential to reduce building energy consumption.
2. Experiment platform
To compare the thermal insulation performance of solar PV vacuum glazing skylight (SPVGS) with that of the vacuum glazing skylight (VGS) and to measure its PV power generation, an experimental test rig was constructed using wooden panels, as shown in Figure 1. The rig measured 1940 mm × 700 mm × 680 mm (length × width × height) and was equipped with a CdTe-based SPVGS (50% PV coverage ratio) and a VGS. Both skylights were identical in size, measuring 875 mm × 602 mm. To conduct the outdoor experiment, the test rig was placed on the sixth-floor outdoor platform of Building Z at The Hong Kong Polytechnic University. Testing was conducted on 7 June 2025, from 9:00 a.m. to 7:00 p.m.
As shown in Figure 2, three K-type thermocouples were attached on each side of the skylights to measure inner and outer surface temperatures, with averaged values recorded as Tin and Tout. At the centre of the interior glazing surface, heat flux sensors (Captec, NHS-25 and HS-30) were installed to measure the heat flux density through the skylights into the indoor environment. Inside the test rig, two measurement points were selected for recording indoor air temperature, while a pyranometer (EKO, MS802) was placed at the bottom to quantify the transmitted solar irradiance of the skylight. An additional pyranometer was placed outside the experimental platform to measure incident solar irradiance, and a weather station was used simultaneously to record outdoor air temperature.
For data acquisition, two dataloggers (GRAPHTEC, GL840) were employed to record the inner and outer surface temperatures of the skylights, indoor air temperature, interior surface heat flux density, and transmitted solar irradiance. The photovoltaic (PV) performance of the SPVGS was monitored using an IV-checker, which tracked its maximum power point and recorded the corresponding electrical data. All measurements were logged at one-minute intervals. The details of the instruments involved in the test are summarized in Table 1.
Table 1. Measuring equipment and their corresponding specifications.
| Measuring equipment | Function | Manufacture and model | Accuracy |
|---|---|---|---|
| Heat flux sensor | Heat flux measuring | Captec (NHS-25 and HS-30) | < 3% |
| Thermocouple | Temperature measuring | K-type | ±0.5 °C |
| Pyranometer | Incident solar irradiance measuring | EKO instrument (MS802) | Non-linearity < 0.2% (at 1000 W/m2) |
| Weather station | Outdoor air temperature measuring | Spectrum Technologies (model 2550) | ±0.3 °C |
| Data logger | Data acquisition | GRAPHTEC (GL840) | — |
| IV-checker | PV power output collection | EKO instrument (MP-11) | — |
3. Results and discussions
3.1. PV power generation
The primary distinction between SPVGS and VGS is that the former one can absorb solar radiation and convert it into electricity through photovoltaic processes. This enables SPVGS to provide clean electricity for powering buildings, thereby contributing to the reduction of energy consumption. As evidenced in Figure 3, the electrical output exhibits a positive correlation with increasing solar radiation, while the aggregate conversion efficiency of the solar photovoltaic coating approximates 8.1%. The maximum power output reached 78.4 W/m2.
3.2. Thermal performance
Regarding thermal insulation performance, Figure 4 shows that the maximum temperature difference between the inner and outer surfaces of SPVGS reaches 43.7 °C (inner surface: 26.5 °C; outer surface: 70.2 °C). This value substantially exceeds the 22.3 °C of temperature difference observed in VGS (inner surface: 28.5 °C; outer surface: 50.8 °C). This comparative analysis demonstrates that the photovoltaic-integrated variant effectively obstructs greater thermal energy transfer into interior spaces, consequently mitigating indoor temperature elevation through conductive heat gain. This thermal behaviour can be attributed to the CdTe coating integrated within SPVGS, which absorbs incident solar radiation, thereby diminishing thermal energy transmission to the underlying glass layer and reducing resultant heat flux. During the power generation process, merely a minor fraction of solar energy undergoes conversion to clean electricity, whereas the residual portion transforms into waste heat. This energy distribution consequently elevates surface temperatures. Nevertheless, the vacuum interlayer's presence ensures minimal effect on inner surface temperature.
As illustrated in Figure 5, the mean solar transmittance of SPVGS is 10.7%, whereas conventional VGS exhibits a transmittance of 32.5%. It is found that SPVGS demonstrates lower solar transmission due to the shading effect of the solar cells. This indicates that less solar energy is transmitted into interior spaces, thereby lowering the requisite indoor cooling load.
4. Future work
The experiments reported above were limited to a single prototype and a single measurement day in Hong Kong, so the results describe the instantaneous performance of the SPVGS rather than its annual behaviour. Three directions are being pursued to turn these measurements into design guidance.
First, a layer-resolved physical model of the SPVGS will be established. The model couples an optical sub-model for the CdTe and low-emissivity coatings, a one-dimensional thermal network for the glass panes, the vacuum gap, the polyvinyl butyral interlayer and the frame, and a single-diode electrical sub-model, so that the measured surface temperatures, heat flux density and power output can be reproduced without empirical fitting. The model will then be implemented in EnergyPlus and validated against the outdoor data reported in this study and against additional seasonal measurements, so that the whole-building model can be used with confidence for annual energy predictions.
Second, the validated model will be used to extend the assessment from a single day and a single city to a range of climates. Annual thermal, lighting and electrical performance will be simulated for representative locations, including hot-humid (Hong Kong, Singapore and Kuala Lumpur), hot summer–cold winter (Shanghai and Wuhan), cold (Beijing) and severe cold (Harbin) zones, and the trade-off between the PV coverage ratio, the skylight-to-roof area ratio and the cooling load reduction will be quantified region by region.
Third, the scope will be broadened to the issues that determine practical viability: the daylighting quality and visual comfort of the interior, the long-term stability of the vacuum edge seal under thermal cycling, and a life-cycle cost and carbon assessment of the SPVGS relative to conventional skylight glazing.
5. Conclusion
Experimental data indicate that the SPVGS can achieve a maximum photovoltaic power generation of 78.4 W/m2 while lowering the solar transmittance to only 10.7%. These characteristics highlight its potential as an effective energy-saving solution. This study presents innovative applications of SPVGS in buildings, specifically focusing on its use as a replacement for traditional skylights to reduce building energy consumption and enhance thermal comfort.
Declarations
Author contributions. Wenhao Zhu: Conceptualization, Methodology, Investigation, Formal analysis, Data curation, Writing (original draft), Visualization, Validation, Software. Hao Zhou: Conceptualization, Writing (review and editing), Supervision, Project administration, Resources, Software, Validation. Hongxing Yang: Conceptualization, Writing (review and editing), Supervision, Project administration, Resources, Funding acquisition, Software.
Funding. This research received no specific funding.
Conflicts of interest. The authors declare no competing interests.
Data availability. The data that support the findings of this study are available from the corresponding author upon reasonable request.
References
- El-Abd, Wessam; Kamel, Basil; Afify, Moemen; Dorra, Medhat (2018) 'Assessment of skylight design configurations on daylighting performance in shopping malls: A case study', Solar Energy, 170, pp. 358-368. Available at: https://doi.org/10.1016/j.solener.2018.05.052
- Fan, Zhengyu; Xiao, Ziyi; Liu, Jiaping (2022) 'Energy performance assessment of semi-transparent photovoltaic integrated large-scale railway stations among various climates of China', Energy Conversion and Management, 269, pp. 115984. Available at: https://doi.org/10.1016/j.enconman.2022.115984
- GovHK (2025) Climate change. Hong Kong: Government of the Hong Kong Special Administrative Region. Available at: https://www.gov.hk/en/residents/environment/global/climate.htm
- Pu, Jihong; Li, Yingxiao; Xu, Dan; Shen, Chao; Lu, Lin (2025) 'A quantitative investigation on the cooling benefits of retrofitting building skylights with broadband-spectrum selectivity in China', Applied Energy, 381, pp. 125101. Available at: https://doi.org/10.1016/j.apenergy.2024.125101
- Zhou, Hao; Yang, Hongxing; Peng, Jinqing (2024) 'Solar PV vacuum glazing (SVG) insulated building facades: Thermal and electrical performances', Applied Energy, 376, pp. 124323. Available at: https://doi.org/10.1016/j.apenergy.2024.124323
How to cite this article
Zhu, W., Zhou, H. and Yang, H. (2026). 'Experimental study on the thermal and electrical performance of solar PV vacuum glazing skylights'. SET Proceedings, 22, pp. 293-298. https://doi.org/10.65582/set.2026.025
