Skip to content
Caravel Press

Conference paper

Experimental study on a CO2-solid-gas-flow-based ultra-low temperature cascade refrigeration system

, ,

1Energy Conversion research Center, Doshisha University, Kyoto, Japan

2SINTEF Energy Research, NO-7465 Trondheim, Norway

Published
24 August 2010
Pages
1-6
Received
24 August 2010
DOI
10.65582/set.2010.017
Access
Open access, © 2010 Copyright WSSET
Download PDF6 pages · 387 KB

Abstract

CO2 solid-gas two phase flow is investigated in an ultra-low temperature cascade refrigeration system. Visualization test shows that dry ice sedimentation occurs in low mass flow rate. The sedimentation also occurs at low condensation temperature and low heating power input. Based on the present investigation, it is found that the present ultra-low temperature cascade refrigeration system is better to work at heating power input above 900W and condensation temperature above -20°C. At suitable operating condition, the present ultra-low temperature cascade refrigeration system has been shown the capability of achieving ultra-low temperature -62°C continuously and stably

© 2010 Copyright WSSET